Exercise:
1. Pull down the Configuration menu and select the IEEE Interface... sub menu
or click on the IEEE connector symbol in the Toolbar. This will bring up the
IEEE Address window.
2. Set the IEEE address to 1 or the address that is configured on the L Series
unit. The factory default for L Series AC sources is IEEE address 1 but this
value can be changed from the front panel of the unit.
3. Select the Card type to match the IEEE controller you are using. If you
have an Hewlett Packard type controller card, you must also set the slot
number used for this card. The default slot number is 7 but values from 0 to 11
are allowed.
4. If the IEEE address and card type settings are incorrect, you will not be able
to communicate with the AC source.
5. If you have an actual unit connected, turn off the Simulation Mode by
removing the Check mark. You should now be able to interface to the AC
source using the command line. If you do not have an AC Source connected at
this time, leave the Simulation Mode enabled and click on OK to close this
window. You can proceed to the next paragraph.
6. Use the pull down menu to select a command such as TLK STA (TaLK
STAtus). Next click on the Send button to send the command.