W Parameters of an SD2x Low-pass 1./2. order A low-pass is used to suppress noise in the reference current value. This noise is created e.g. by noisy speed measurement. By means of the low-pass losses in the power output stage and in the motor can be reduced. You can use a low-pass 1. order or a low-pass 2. order with Butterworth characteristic. Set the desired filter and enter the 3 dB cut-off frequency of the filter. The unit is hertz. Please consider that a low-pass in the reference current value reduces the dynamics of the current control. For this reason you must possibly adapt the control parameter of the speed controller (reduce the amplification and increase the integration time). Band-stop filter A band-stop filter is used to suppress resonance frequencies caused by the mechan‐ ical construction of the driven machine. Enter the center frequency of the band-stop filter. The bandwidth is set automatically. The unit is hertz. Please consider that a band-stop filter in the reference current value can reduce the dynamics of the current control. For this reason you must possibly adapt the control parameter of the speed controller (reduce the amplification and increase the integration time). Current Controller (SD2x, SVC) SERVO / VECTOR (SVC) HSPWM HSBLOCK / FPAM HSPAM / VF ✔ ‒ ‒ ‒ On this page you can set the parameters of the current controller for SVC operation. These are the current limitation, the holding current and the bandwidths. Fig. 50: Parameter page "Current controller" drivemaster2 - User Manual 143 10