CHAPTER 7: Serial RS232/RS485 and USB Interface
7.1 Introduction
This chapter describes the set-up, operation, commands and communication protocol of Z+ power
supplies via serial communication interfaces: RS232, RS485 or USB.
7.2 Configuration
Function Level
Interface
Display
N
Parameter
Level
Display
232

485

USB

LAN

IEEE

Address

1….31
1
Baud Rate

1200..57600

Language

SCPI
SCP I
GEN
G
IP Address

IP1---IP4


MAC Address

MAC1-MAC6


LAN Reset

Yes
Description
Available only if IEEE or LAN option installed
Available only if LAN option installed

Table 7-1: Front panel setup
7.2.1 Default Setting
Refer to Table 5-7: Memory parameters.
7.2.2 Address Setting
The power supply address can be set to any address between 1 and 31.
1. Press REM button. The REM LED illuminates. ”” message appears on the Current display.
2. Press Current encoder. Voltage display shows ”” and Current display shows present address.
3. Rotate the Current encoder to select required address.
4. Press Current encoder to enter selected parameter to memory.
5. When parameter is accepted the display blinks once and returns to the previous level.
7.2.3 Communication Interface Selection
Z+ power supply can be configured for RS232, RS485 or USB communication interface.
1. Press REM button. The REM LED illuminates. ”N” message appears on the Voltage display.
2. Press Voltage encoder. Voltage display shows ”N” and Current display shows communication
interface.
3. Rotate the Current encoder to select the required interface.
4. Press Current encoder to enter selected parameter to memory.
5. When parameter is accepted the display blinks once and returns to the previous level.
82