Download WESCHLER INSTRUMENTS
Transcript
WESCHLER INSTRUMENTS AEMC Power Quality Loggers • Simple operation: Plug in, Record, Download and Read • Measures and stores V, A, Hz, W, VA, VAR, Demand, Peak Demand, Harmonics, THD, K-Factor and more • Automatically captures worst-case Surge, Sag and THD waveforms • Takes 128 samples/cycle with 16 bit resolution • Records up to 12 data channels • Three LED status indicators • Powered from voltage input channel PQL100 with battery backup for data memory • Optically isolated RS-232 output for direct connection to a PC • Includes DB9 serial cable & DataView® software for data storage, analysis and report generation SPECIFICATIONS Measurements Voltage TRMS Current TRMS Frequency Harmonics Watt/VA/VAR Power & Power Factor Programmable Parameters ORDERING INFORMATION AE/2125.03 AE/2125.04 AE/2119.02 PQL 100 Power Quality Logger with integral 3-prong power plug PQL 120 Power Quality Logger with 6 ft power cord Soft Carrying Case Demand Peak Demand Voltage Surge & Sag Storage Rate Recording Session Total Memory Waveform Storage Operating Temperature Dimensions Safety Rating Simultaneously voltage and current measurements. 0 to 140V, 0.1V resolution Accuracy ±(0.3% of Reading + 0.3V) 0 to 15A (70A peak maximum), 0.01A resolution Accuracy ±(0.5% of Reading + 0.03A) @ 0.75A to 15A 45 to 65Hz, 0.01Hz resolution & accuracy to 50th for both Voltage & Current 0 to 2100 with 0.1 resolution Accuracy ±(2.0% of Reading + 40 counts) 0.01 resolution, Accuracy ±0.03% @ PF/DPF = 1 V, A, Hz, Odd & Even Harmonics (V & A), W, VA, Var, THD (V & A), PF, DF, K-Factor VA, W (10/15/30 minutes or user-definable) Over demand period User-definable magnitude 125ms to 7 days Length 15 minutes to 8 weeks (user programmable) 1MB 20 worst-case -10° to 50°C, <85% RH to 35°C 5.91 x 3.15 x 2.36" (150 x 80 x 60mm) IEC 1010-1, 150V Cat. III, Pollution Degree 2 AEMC Voltage & Current Data Loggers SDL Sentinel® MODEL MODEL No. of Channels Input Termination Input Type Voltage Range SDL V301 SDL V301 Three Recessed banana jacks AC/DC Volts 0 to 600VAC 0 to 850VDC • 3 or 4 Channels • True RMS measurements • Low-cost, self-contained, portable • Differential three-phase voltage inputs • Integral flexible current probe • 3 Programmable storage modes • Programmable data storage rate • Records up to 480,000 points • 64 samples per cycle • Optically isolated USB 2.0 communication • Includes DataView® software for real time display, data storage, analysis & report generation SDL V401 SDL V401 Four Recessed banana jacks AC/DC Volts 0 to 600VAC 0 to 850VDC Current Range Resolution Accuracy Power Source Battery Life Hardware Included Catalog Number 122a 64 samples/cycle 250ms to 12 hours, programmable Stop when full, FIFO, XRM* 1MB, 480,000 readings Optically isolated USB 2.0 One button for on/off & start/stop Red, yellow & green status LEDs IP50, except BNC models 600V CAT III 6.73 x 4.76 x 2.17" (171 x 121 x 55mm) * In XRM, each time the memory fills, every other of the oldest data samples is discarded to make room for new samples. SDL A301 SDL A301 Three Hard-wired flexible CTs AC Amps SDL A302 SDL A302 Three Hard-wired flexible CTs AC Amps SDL A303 SDL A303 Three Hard-wired flexible CTs AC Amps SDL A304 SDL A304 Three Hard-wired flexible CTs AC Amps SDL A401 SDL A401 Four BNC SDL A402 SDL A402 Four BNC AC Amps AC/DC Amps 5 to 1000A 15 to 3000A 5 to 1000A 15 to 3000A 0.1A ±1% of rdg ±1.5A 0.25A ±1% of rdg ±1.5A 0.1A ±1% of rdg ±1.5A 0.25A ±1% of rdg ±1.5A 5 to 1000A or 15 to 3000A, sensor dependent 0.25A ±1% of rdg ±1.5A Probe with voltage output req’d (order separately) Probe dependent Probe dependent AC power/ NiMH batteries Power ride through 10 hours Three hard-wired flexible CTs, batteries, 120V wall charger AE/2134.17 AC power/ NiMH batteries Power ride through 10 hours Three hard-wired flexible CTs, batteries, 120V wall charger AE/2134.18 AC power/ NiMH batteries Power ride through 10 hours Batteries, 120V wall AC power/ NiMH batteries Power ride through 10 hours Batteries, 120V wall charger AE/2134.19 AE/2134.20 0.1V 0.1V ±0.25% of rdg ±0.6V from 85-600V ±1.0% of rdg ±0.6V from 5-85V Alkaline batteries AC power/ NiMH batteries 100 hours Power ride to 90 days through 10 hours Six color-coded Eight color-coded leads, leads, batteries, batteries, 120V wall charger Alkaline batteries Alkaline batteries 100 hours to 45 days Three hard-wired flexible CTs, batteries 100 hours to 45 days Three hard-wired flexible CTs, batteries AE/2134.10 AE/2134.15 AE/2134.16 AE/2134.11 SPECIFICATIONS Sample Rate Storage Rate Record Modes Memory Capacity Communications Controls Indicators Protection Rating Dimensions WESCHLER INSTRUMENTS • www.weschler.com • 800-903-9870 • fax: 800-903-9590 • [email protected]