Download Optima Series COMMAND REFERENCE
Transcript
AT (Binary D2) FUNCTION: At Time DESCRIPTION: The AT command is a trippoint which is used to hold up execution of the next command until after the specified time has elapsed. The time is measured with respect to a defined reference time. AT 0 establishes the initial reference. AT n specifies n msec from the reference. AT -n specifies n msec from the reference and establishes a new reference after the elapsed time period. ARGUMENTS: AT n where n is a signed, even integer in the range 0 to 2 Billion n = 0 defines a reference time at current time n > 0 specifies a wait time of n msec from the reference time n < 0 specifies a wait time of n msec from the reference time and re-sets the reference time when the trippoint is satisfied. (AT -n is equivalent to AT n; AT <old reference +n> USAGE: DEFAULTS: While Moving Yes Default Value 0 In a Program Yes Default Format - Command Line Yes Controller Usage ALL CONTROLLERS EXAMPLES: The following commands are sent sequentially AT 0 Establishes reference time 0 as current time AT 50 Waits 50 msec from reference 0 AT 100 Waits 100 msec from reference 0 AT -150 Waits 150 msec from reference 0 and sets new reference at 150 AT 80 Waits 80 msec from new reference (total elapsed time is 230 msec) Optima Series Command Reference AT (Binary D2)i 25