TIMER S4
-
TAU
thousandth on or off
AUS = thousandth off
EIN = thousandth on
-
HUn
hundredth on or off
AUS = hundredth off
EIN = hundredth on
-
AUT
display automatic on or off
EIN = you can set the display time with variable SLP
EINL = only the first time will be shown on the display board
AUS = manual change of display with yellow key (7)
-
Pri
printer speed (set up 60 for Printer P3)
Input range: 0 to 9.9 (0 = off, 0.1= fast, 9.9 = slow)
-
Lr
line feed for printer
Input range: 0 to 9 (amount of line feeds after each line)
-
di.
photocell distance for speed measurement
Input range: 1 to 180 Meter
-
A00
Amount of touches for swimming
Input range: 0 to 99 touches
-
n01
competition number and running number for swimming
Input range: 0 to 99
Page 18
How to set the options:
o
o
o
o
o
o
o
o
o
o
press toggle switch (8) upwards (program+line test)
turn Timer S4 on (switch 17)
release toggle switch (8) when display (1) shows 8.8:8.8:8.8.88
select program with yellow button (7)
press yellow and red button (6+7) together
program is ready for timing
press toggle switch (8) downwards (delay time)
changing of options is now possible
increment choices with yellow and red button (6+7) red button is for left of the decimal,
yellow for right
press toggle switch (8) downwards (delay time) to set the next variable
2.6.1. Set delay time:
dF and dS
Time to prevent accidental recording of extra impulses.You will need to experiment with this feature
somewhat as it will change between sports and the start interval that determines the likelyhood of
atheletes bunching up as they approach the finish.
The delay is designed to prevent the timer from receiving another impulse from the same channel
for a definite time after an impulse. You can set the delay time separate for the start channels and
finish channels.
Version: E-06-04-18