Download photodetector module DM0089C data sheet ENS- ECH
Transcript
photodetector module DM0089C data sheet SENS-TECH SENSOR TECHNOLOGIES 1 description The DM0089C photodetector module comprises a type 9111B80 25 mm diameter end-window photomultiplier tube with blue-green sensitive bialkali photocathode with low dark counts, a positive high voltage power supply and a high speed amplifier-discriminator. The model includes a counter and micro-controller with USB interface. All are encapsulated within a rectangular metal case with connectors for power input and USB signal output. 2 applications Intended for ultra-low light measurement applications requiring single photon detection. Utilises a USB interface to a host computer. 3 features 6 easy to operate compact rectangular assembly electrostatic shielding operates from low voltage supply preset discriminator level and HV fully enclosed high voltages only 500 mW total power dissipation (typical) 70 MHz count rate capability wide dynamic range 4 30 quant um ef f i ci ency % · · · · · · · · · photocathode spectral response UV glass bialkali 20 10 accessories 0 · adaptor for SMA terminated optical fibre, type DMSMA · universal ac power adaptor, type PSU5V-3A · USB cable with type A plug 5 characteristics photocathode type photocathode active diameter spectral response range peak QE at 400 nm output control discriminator level dark counts at 20 °C (typ.) (max.) 7 -1 power input at 10 s warm up time input voltage temperature (operating) (storage) weight operating position finish 100 7 300 500 wavelength nm 700 900 user I/O connections TTL input and output lines are available for control of the module and to command peripheral operations. bialkali 22 mm 280 to 630 nm, see curve 28 % USB see user manual -2 mV -1 50 s -1 200 s +5 V, 100 mA less than 10 s +4.75 V to +5.25 V +5 °C to +55 °C -40 °C to +55 °C 200 g any case, black powder coat front plate, black anodised trigger input user output 8 start command for cycle defined by software 5V logic output for user applications. For example: activate shutter; busy indicator user manual & software link A manual giving detailed instalation, start-up, software link and programming procedures is supplied by e-mail after receipt of purchase order.. 9 test data Module test data is supplied on request. DM0089C data sheet page 2 10 dynamic range 12 outline drawing (mm) Typical counting sensitivity for DM0089C at 400 nm. Note that automatic dead time correction has been applied at high count rates. The dynamic range can be further extended at low count rates by dark count subtraction in the software. 10 output counts s-1 10 10 8 10 5 6 3 1 8 13.5 4 Hirose HR10-7R-6P 6 way fixed plug pin 1 USB 0 V 2 USB power 3 USB DM 4 USB DP 5 user out 6 trigger in 2 7 15.0 crs 6 Pin designations 10 10 10 5 power input +4.75 V to +5.25 V 2.1 mm dc power connector (centre positive) 4 3 10 2 10 count subtraction darkdark count subtraction 1 10 -17 10 -16 10 -15 10 -14 10 -13 10 -12 10 -11 10 -10 10 4 holes, M3 x 6.5 deep on 25 centres -9 incident light power W at 400 nm and 20 °C ±0.25 11 functional diagram 80.0 photomultiplier photocathode anode dynodes ±0.25 15.7 +ve HV supply disable HV +5V (red) 22.0 dia active area amplifier / discriminator 0V (black) trigger in (grey) USB type A plug USB interface microcontroller user out (violet) ±0.25 ±0.25 32.0 56.5 13 installation and operation counter Each module is supplied with test data. Wherever possible carry out installation in subdued light. Remove the protective cap from the window of the module. If necessary, clean the photomultiplier window using a lens tissue moistened with alcohol. Do not use any other solvent. Mount the module and make power input and signal connections. Do not expose the photomultiplier tube photocathode to strong lights while the module is energised. 14 warning Do not attempt to repair or dismantle this product. High voltage used within the module presents an electric shock hazard. Do not operate beyond the maximum ratings, or reverse the input voltage; this may result in loss of performance or permanent damage to the product. Sens-Tech Limited 6A Langley Business Centre, Station Road, Langley Berkshire, SL3 8DS, UK tel: +44 (0)1753 214714 fax: +44 (0)1753 214715 e-mail: [email protected] The company reserves the right to modify these designs and specifications without notice. Developmental devices are intended for evaluation and no obligation is assumed for future manufacture. While every effort is made to ensure accuracy of published information the company cannot be held responsible for errors or consequences arising therefrom. an ISO 9001 registered company www.sens-tech.com SENS-TECH SENSOR TECHNOLOGIES © Sens-Tech Limited DS_DM0089C Issue 3 28 March 2014