Download ENS- ECH photodetector module P30232
Transcript
photodetector module P30232 SENS-TECH SENSOR TECHNOLOGIES 1 description The P30232 is a plug-and-play photodetector module, configured for photon counting. It comprises a selected 30 mm diameter end window photomultiplier tube with blue-green sensitive bialkali photocathode and ultra-low dark counts, a positive high voltage power supply, a high speed amplifierdiscriminator, a counter and a micro controller. All are encapsulated within a cylindrical mumetal* case, providing a high level of immunity from the effects of external magnetic fields. Low voltage and signal output connections to the module are by axial flying leads. 2 application ! intended for ultra-low light measurements requiring single photon detection via an RS232 interface to a host PC. 3 features ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! simplicity of operation minimal set up time compact cylindrical assembly electrostatic and magnetic shielding RS232 interface quartz window option 20 MHz count rate capability automatic dead time correction operates from +5 V supply preset discriminator level and HV fully enclosed high voltages only 600 mW total power dissipation (typical) discriminator threshold preset to -2 mV HV factory set for optimum operating voltage will operate with any PC running Windows® 95/98, with a free RS232 serial port 4 user manual A manual giving detailed installation, start-up software and programming procedures is supplied with every package. 5 test data Each module is supplied with test data including photocathode parameters and dark counts. 6 characteristics photocathode type photocathode active diameter spectral response range peak QE at 400 nm output baud rate parity data bits stop bits control discriminator level dark counts at 20 °C (typ.) (max.) 6 -1 power input at 10 s warm up time ratings input voltage temperature (operating) (storage) humidity (non-condensing) weight operating position finish 7 bialkali 25 mm 280 to 630 nm, see curve 28 % RS232 9600 None 8 1 see user manual -2 mV -1 100 s -1 200 s +5 V, 120 mA less than 2 s +4.75 V to +5.25 V +5 °C to +55 °C -40 °C to +55 °C 93 % RH maximum at 30 ºC 310 g any matt black user I/O connections TTL input and output lines are available for control of the module and to command peripheral operations. trigger input (grey) start command for cycle defined by software user output (violet) start command for user applications. For example: activate shutter; busy indicator P30232 data sheet page 2 11 outline drawing mm photocathode spectral response 8 ø35.0 ±0.5 quantum efficiency % 30 quartz 25.0 active diameter 20 photomultiplier 10 9 181.5 ±1 mumetal* case 0 100 300 500 700 wavelength nm 900 dynamic range Typical counting sensitivity for P30232 at 400 nm. Note that automatic dead time correction has been applied at high count rates. The dynamic range can be further extended at low count rates by dark count subtraction in the software. 10 output counts s-1 10 10 8 610 ±50 108 7 1850 ±50 6 10 10 10 5 9 way ‘D’ socket 2 Tx 3 Rx 5 Gnd 4 3 10 +5V Red 0V Black I/O out Violet I/O in Grey 2 10 dark count subtraction 1 10 -17 10 -16 10 -15 10 -14 10 -13 10 12 -12 10 -11 10 -10 10 -9 incident light power W at 400 nm and 20 °C 10 screened cable Each module is supplied with test data. Wherever possible installation should be carried out in subdued light. Remove the protective cap from the module. Mount the module and make power input and signal connections. functional diagram photomultiplier photocathode installation and operation Do not expose the photomultiplier tube photocathode to strong lights while the module is energised. anode dynodes 13 +ve HV supply disable HV +5V (red) amplifier / discriminator 0V (black) trigger in (grey) Tx (pin 2) Rx (pin 3) 0V (pin 5) RS232 interface Sens-Tech Limited Bury Street, Ruislip Middx HA4 7TA, UK tel: +44 (0) 1895 630771 fax: +44 (0) 1895 635953 e-mail: [email protected] microcontroller user out (violet) warning No attempt must be made to repair or dismantle this product. High voltage used within the module may present an electric shock hazard. Operation beyond the maximum ratings, or reversal of the input voltage may result in loss of performance or permanent damage to the product. counter *mumetal is a registered trademark of Magnetic Shield Corporation The company reserves the right to modify these designs and specifications without notice. Developmental devices are intended for evaluation and no obligation is assumed for future manufacture. While every effort is made to ensure accuracy of published information the company cannot be held responsible for errors or consequences arising therefrom. an ISO 9001 registered company www.sens-tech.com SENS-TECH SENSOR TECHNOLOGIES © Sens-Tech Limited, 2007 DS_ P30232 Issue 1 30 march 2007