OPERATION
4.4 SETTINGS IN THE EXTENDED MENU
4.4.8 Distance from the label stop
sensor to the dispensing edge
(E–SS)
– Correct specification of the distance between the label stop sensor and the dispensing edge is a prerequisite for setting the label stop position (STOD).
A
Set distance
➔ Adjust the distance between the label stop sensor
and dispensing edge. Round the measured value
up to a whole number value in mm.
In the extended menu:
➔ Call up the E–SS function.
➔ Input the distance value.
– Settings are possible in 1 mm steps:
Minimum: 12 mm
Maximum: 1000 mm
– A maximum of 15 labels can be located between the
photoelectric sensor and the dispensing edge.
➔ Confirm the value using the ENTER key and exit the
function.
[63] A Distance between the label stop sensor and dispensing edge
➔ Check setting (see next page).
The minimum setting depends on the dispensing speed.
– The greater the dispensing speed, the greater the minimum distance.
– If the minimum distance is not maintained,
the warning message W__7 appears.
60