Download MES User Manual - Inductive Automation
Transcript
OEE Downtime Properties Int4 Read Only Active Downtime Is a Short Stop Accumulation Count = Infeed Count - Run Production Count. This represents the amount of product accumulated on the production line and is adjusted for package count. It will be the same units as the infeed. Indicates the time, in a formatted string, that the current line downtime event has been active. Indicates if the current active line downtime event is a short stop. Active Downtime Starttime Indicates the start time that the current line downtime event started. DateTime Read Only Actual Changeover End Time Indicates the time that the current run ended changeover status and began running. The date and time that Enable Run property was set to false. This typically happens when the operator clicks the End button. The date and time that Enable Run property was set to true. This typically happens when the operator clicks the Start button or a production run auto start occurred (See Line Configuration Schedule Settings for more details). The date and time that new product was selected to run on the line. Typically, this happens when the operator selects a new production run. Indicates if the line is set to automatically start schedule entries and begin the run after any changeover. Overrides "Auto Start Run" setting. Indicates if the production run should start automatically after change over. This will allow the line to record a downtime event if it is not running after the allotted changeover time from the schedule entry. This value will increment every time OEE, downtime and scheduling values are calculated for the project production model. Indicates if this run can be cancelled. Runs can only be cancelled while in changeover If true, all conditions are good to resume a production run. DateTime Read Only Accumulation Count Active Downtime Duration Actual Finish Time Actual Run Start Time Actual Start Time Auto Run Schedule Auto Start Run Calculate Count Can Cancel Run Can Resume Run © Inductive Automation String Read Only Boolean Read Only DateTime Read Only DateTime Read Only DateTime Read Only Boolean Read Only Boolean Read Only Int4 Read Only Boolean Read Only Boolean Read Only 131
Related documents
MES User Manual - Inductive Automation
MES User Manual - Inductive Automation
Kyubit AnalysisPortal OLAP analysis
3 Overview - Inductive Automation
pCOWeb User manual
OSPInSight Edit for Esri 8 - Advance Fiber Optics, Inc.
Intermediate XSLT and XPath
2 Overview - Inductive Automation
DropSense Integration Manual
Analysis and Actions for Robust Electronics Production
M100775B - MERLIN Dashboard User Guide 1-31-2013
Stratix Switches Within Integrated Architecture