Chapter 4: Testing with the Genos System Genos User Manual Figure 4.20 - Loop to Repeat the Test with Increased Power Level. After the DUT found five satellites, another set of conditional commands will execute looking for the DUT to obtain a valid location "fix". Again the simulation will wait 150 seconds for the DUT to obtain the "fix", and if it does NOT obtain the "fix" the simulation will stop, power will be increased by 3 dBm, and it will loop back to the "Cold Start" command. Note that all commands will may be repeated through the second "loop" command. That is, the DUT must again find at least 5 satellites before it can enter the second set of conditional statements. Finally, when the DUT has successfully found at least 5 satellites and obtained a valid location "fix",the simulation will wait for 20 seconds and then stop the simulation. The EOF command will stop the test. Figure 4.21 - Second Conditional Command Set and Test Stop Commands - 39 -