Download Manual - TopsCCC

Transcript
EX92026 User’s manual
4.3
EX92026 User’s manual
Analog Input Polarity and Range selection
JP1 is the polarity and maximum input range selection jumper. The following table
shows the two configurations.
Polarity
(JP1)
2
2
4
3
8
4
1
5
2
6
7
4
8
8
1
-5~+5V
-2.5V~+2.5V
-1.25V~+1.25V
Bipolar
-0.625V~+0.625V
0V~+10V
1
1
1
0V~+5V
Unipolar
0V~+2.5V
0V~+1.25V
1
0
Max. Input range
1
AD_Range value Gain
-10~+10V
Bipolar
4.4
Analog output (D/A) range selection
JP2 is the selection jumper of analog output range. The following table shows the
two possible output ranges
Analog Output Range
1
JP2
1
-10V~+10V
0V~+10V
21
22