Download BeanDevice® ProcessSensor User Manual
Transcript
“Rethinking sensing technology” Document Type : User Manual 9.4.2 Document version:2.0 BeanDevice® User Manual – ProcessSensor product lines Sensor configuration & calibration This frame contains a set of 5 tabs: Custom Display Notes Configuration Measurement conditionning & calibration Log configuration • Allows the end user to customzie the sensor • Contains notes relating to the BeanDevice® sensor • Sensor configuration interface. The user can configure the alarm thresholds related to the sensor • Depending on the BeanDevice® version which is used, other configuration parameters are available • Sensor or measurement channel calibration • Logs configuration on the BeanScape® 9.4.2.1 Tab: Custom display These parameters allow the user to customize his sensor: Type: Describe the sensor type (ex: load cell, pressure, Strain gage +/- 2 Mv/v, LVDT,…. ) Unit: customer sensor unit (bar, °C, l/h….) Ratio : Sensor Ratio coefficient (RAT); Offset : Sensor Offset Coefficient (OFF); Label: Give a name to your sensor. (ex : Sensor on StatorMachine 1, sensor in Room 2 Floor 3) Please consider the environment before printing this document. Page : 94 / 134