Download Installation Instructions
Transcript
5-2 PLC Ladder Logic Programming What Are PLC Ladder Logic Programs? A PLC ladder logic program lets you control the drive and the messaging from the PLC to the drive. Figure 5.1 shows how the I/O image table for the controller (e.g., PLC) relates to the 1336 PLUS drive when a 1203-CN1 module is used. Figure 5.1 I/O Image Table ControlNet Controller SCANport 1203-CN1 Module➂ 1336 PLUS Drive➃ Output➀ Nxx:0 Nxx:1 Nxx:2 Nxx:3 Nxx:4 Nxx:5 Nxx:6 Nxx:7 Nxx:8 Nxx:9 Logic Command Reference Data Link A1 Data Link A2 Data Link B1 Data Link B2 Data Link C1 Data Link C2 Data Link D1 Data Link D2 Logic Command Reference Data In A1 Data In A2 Data In B1 Data In B2 Data In C1 Data In C2 Data In D1 Data In D2 Input➁ Nxx:0 Nxx:1 Nxx:2 Nxx:3 Nxx:4 Nxx:5 Nxx:6 Nxx:7 Nxx:8 Nxx:9 ➀ Logic Status Feedback Data Link A1 Data Link A2 Data Link B1 Data Link B2 Data Link C1 Data Link C2 Data Link D1 Data Link D2 Logic Status Feedback Data Out A1 Data Out A2 Data Out B1 Data Out B2 Data Out C1 Data Out C2 Data Out D1 Data Out D2 The N-file number depends on the value entered for the Data Output File field in RSNetWorx. You can also configure this as an I/O address. ➁ The N-file number depends on the value entered for the Data Input File field in RSNetworx. You can also configure this as an I/O address. ➂ You must enable each datalink in the module. Refer to Appendix B, 1203-CN1 Module Parameters, and Chapter 3, Getting Started, for more information. ➃ You must configure the datalinks in the SCANport product. Refer to your SCANport product’s user manual for more information. Publication 1203-5.13 – February, 2002