Download E, SG - Derrick Corporation
Transcript
MAINTENANCE ALARM AND FAULT MESSAGES Cause Corrective Action F1000 - Bowl Exceeded Maximum Speed, Shutdown Incorrect or loose connection at speed sensor or defective speed sensor Check speed sensor connection (refer to Section 3). Replace sensor if defective. Bowl VFD malfunction If problem persists, contact Derrick Service for assistance. F1001 - Bowl High Torque Alarm, Reduce Feed Rate Bowl torque exceeds pre-set limit Reduce feed rate and/or reduce bowl speed. F1002 - Bowl High Torque Fault and Shutdown, Perform Cleanout and Reduce Feed Rate Bowl torque exceeds pre-set limit After bowl has stopped rotating, perform cleanout procedure to remove solids buildup, and re-start centrifuge at reduced feed rate. F1010 - Bowl VFD Communications Error Communication lost between bowl VFD and PLC Confirm that green LED next to Ethernet cable on Ethernet switch is lighted, indicating that hub is functional. Check connections between bowl VFD and PLC, and correct any defects. Replace bowl VFD communication module, if no other defect is found. F1011 - Bowl VFD Alarm, Ref Troubleshooting Section of User Manual Bowl VFD alarm Identify alarm from operator control panel. Perform indicated corrective action. F1012 - Bowl VFD Fault and Shutdown, Ref Troubleshooting Section of User Manual Bowl VFD fault Identify fault from operator control panel. Perform indicated corrective action. F1013 - Bowl VFD Ground Warn Alarm, Ref Troubleshooting Section of User Manual Bowl VFD has detected high current leakage to ground Check condition of cable and all connections between bowl VFD and bowl motor, and correct any defects. F1014 - Bowl VFD In Phase Loss Alarm, Ref Troubleshooting Section of User Manual Bowl VFD has detected unbalance or partial loss of input three-phase power Check wiring between VFD and supply source; correct defect(s). Check supply power, and correct any defects. F1015 - Bowl VFD Power Loss Alarm, Ref Troubleshooting Section of User Manual Incoming power loss or low voltage supply 5-30 DE-1000LPVFDCentrifuge Check incoming power and correct any defect(s). 01 Jan 14