Download E, SG - Derrick Corporation
Transcript
MAINTENANCE ALARM AND FAULT MESSAGES Cause Corrective Action F4006 - Solid End Main Bearing High Temperature Fault and Shutdown Insufficient bearing lubrication Lubricate bearings (refer to Preventive Maintenance). Excess grease Remove grease fitting, and direct jet of filtered compressed air into opening to remove grease. Incorrect grease Lubricate with recommended grease (refer to Preventive Maintenance). Defective bearing Contact Derrick Service department for assistance. F7011 - Air Conditioner Compressor Motor Overload Fault Motor drawing excessive current Confirm proper operation of relays K20 and K30 and adequacy of three-phase power supply. Check all electrical connections. Correct any defects. F7012 - Air Conditioner Internal Fan Motor Overload Fault Motor drawing excessive current Confirm proper operation of relays K20 and K30 and adequacy of three-phase power supply. Check all electrical connections. Correct any defects. F7013 - Air Conditioner Refrigerant Pressure High or Low Fault Refrigerant pressure high or low Attempt to re-start centrifuge. Low pressure will cause immediate shutdown or failure to start; high pressure will permit brief operation and then automatic shutdown. If low pressure indicated, contact Derrick Service for assistance. If high pressure indicated, continue troubleshooting. Condenser motor rotation incorrect or motor defective Check rotation direction, and reverse, if necessary, by switching two leads. Condenser cooling fins clogged Use vacuum cleaner to remove all debris from fins. Condenser motor defective Check motor, and replace if defective. If problem persists, contact Derrick Service for assistance. F7021 - Electrical Enclosure High Temperature Alarm Control cabinet interior temperature has exceeded alarm setpoint Check status/operation of air conditioner; repair or replace if defective. Reduce load by decreasing bowl, conveyor differential speed, and/or pump feed rate. 5-36 DE-1000LPVFDCentrifuge 01 Jan 14