Download User`s Manual - MARUSON Technology
Transcript
POWER PRO 1100 User's Manual Panel Information USB Port AC Input Circuit Breaker Battery Recycling Information UPS contains non-spillable sealed Lead Acid batteries. On the battery, you will the battery name. Please refer to the chart below for recycling information or contact your local distributor for assistance. Battery Name Recycling inside the USA Recycling outside the USA RITAR Battery Network/Modem/ Phone Line Surge Protection (800) 273-8599 N/A Trouble Shooting Full Time Surge Protection Outlets Battery Power Supplied Outlets Problem Possible Cause No LED display Low battery. on the front panel. Ba ttery fault. Charge battery up to 8 hours. UPS is not turned on. Safety Caution SAVE THESE INSTRUCTIONS-This manual contains important instructions for models PRO-1100AVR that should be followed during installation and maintenance of the UPS and batteries. This UPS utilizes voltage that may be hazardous. Do not attempt to disassemble the unit. The unit contains no user replaceable parts. Only factory service personnel may perform repairs. In the event of an emergency, press the "OFF" button and disconnect the power cord from the AC power supply to properly disable the UPS. Do not allow any liquids or any foreign object to enter the UPS. Do not place beverages or any other liquid-containing vessels on or near the unit. This unit is intended installation in a controlled environment (temperature controlled, indoor area free of conductive contaminants). Avoid installing the UPS in locations where there is standing or running water, or excessive humidity. Do not plug the UPS input into its own output. Replace with the same type of battery. Press the power switch again. Alarm buzzer UPS is overloaded. beeps continuously when AC supply is normal. Verify that the load ma tches the UPS capability specified in the specs. When power Ov erload of the UPS. failure, backup Battery voltage is too time is short. low. Remove some noncritical load. Comm un icat ion los t be twee n UPS an d compu ter. Charge battery 8 hours or more. Battery defect . Replace with the same type of battery. Software is not installed properly. Cable is not firml y connected. Check the setting of the software. Internal battery voltage is 12Vdc. Sealed, lead-acid, 6 cells battery. Connection to any other type of receptacle other than a two-pole, threewire grounded receptacle may result in shock hazard as well as violate local electrical codes. Solution Check the USB cable is firml y connected to the comp uter and confirm the setting again. Mains normal Breaker trips. but yellow LED Power cord is loose. brinks. Re set the breaker. Re connect the powe r cord properly. If any abnormal situations occur that are not listed above, please call for service immediately. Specification Do not attach a power strip or surge suppressor to the UPS. PRO-1100AVR Do not attach non-computer-related items, such as medical equipment, life-support equipment, microwave ovens, or vacuum cleaners to UPS. 110/120VAC or 220/230/240VAC 81-145VAC or 162-290VAC To reduce the risk of overheating the UPS, do not cover the UPS' cooling vents and avoid exposing the unit to direct sunlight or installing the unit near heat emitting appliances such as space heater or furnaces. 50/60Hz (Auto Sensing) Unplug the UPS prior to cleaning and do not use liquid or spray detergent. Do not open or mutilate the battery or batteries. Release electrolyte is harmful to the skin and eyes. It may be toxic. Up to A battery can present a risk of electrical shock and high short circuit current. The following precautions should be observed when working on batteries: 1) Remove watches, rings, or other metal objects from the hands. 2) Use tools with insulated handles. 3) Wear rubber gloves and boots. 4) Do not lay tools or metal parts on top of batteries. 5) Disconnect charging source prior to connecting or disconnecting batteries terminal. RJ11/RJ45(One In One Out) 350 x 146 x 160mm 13.8 x 5.7 x 6.3 in 8.0kgs / 21.16lbs Servicing of batteries should be performed or supervised by personnel knowledgeable of batteries and the required precautions. Keep unauthorized personnel away from batteries. When replacing batteries, replace with the same number and type of sealed lead-acid battery. The maximum ambient temperature rating is 40 C. During the installation of this equipment it should be assured that the sum of the leakage currents of the UPS and the connected loads does not exceed 3.5mA. This pluggable type A equipment with battery already installed by the supplier is operator installable and may be operated by laymen. Attention, hazardous through electric shock. Also with disconnection of this unit from the mains, hazardous voltage still may be accessible through supply from battery. The battery supply should be therefore disconnected in the plus and minus pole of the battery when maintenance or service work inside the UPS is necessary. The mains socket outlet that supplies the UPS shall be installed near the UPS and shall be easily accessible. Windows® 2000/2003/XP/Vista/2008, Windows® 7, Linux, Unix, and MAC Specification change without notice. Product Warranty and Service Information: For U.S. customers, please register your product at www.MarusonUSA.com. For international customers, please contact your local authorized distributor or e-mail [email protected] for assistance. Maruson Technology Corporation 18557 E.GALE AVE. CITY OF INDUSTY,CA 91748 P.O. Box 1986 Walnut, CA 91788, USA Toll Free: 1-888-MARUSON TEL: +1-626-912-8388 FAX: +1-626-912-8680 E-mail: [email protected] Web Site: www.MarusonUSA.com