POWER PRO
1100
User's Manual
Panel Information
USB Port
AC Input
Circuit Breaker
Battery Recycling Information
UPS contains non-spillable sealed Lead Acid batteries. On the battery,
you will the battery name. Please refer to the chart below for recycling
information or contact your local distributor for assistance.
Battery Name Recycling inside the USA Recycling outside the USA
RITAR Battery
Network/Modem/
Phone Line
Surge Protection
(800) 273-8599
N/A
Trouble Shooting
Full Time Surge
Protection Outlets
Battery Power
Supplied Outlets
Problem
Possible Cause
No LED display Low battery.
on the front
panel.
Ba ttery fault.
Charge battery up to 8 hours.
UPS is not turned on.
Safety Caution
SAVE THESE INSTRUCTIONS-This manual contains
important instructions for models PRO-1100AVR
that should be followed during installation
and maintenance of the UPS and batteries.
This UPS utilizes voltage that may be hazardous. Do not attempt to
disassemble the unit. The unit contains no user replaceable parts.
Only factory service personnel may perform repairs.
In the event of an emergency, press the "OFF" button and disconnect
the power cord from the AC power supply to properly disable the UPS.
Do not allow any liquids or any foreign object to enter the UPS. Do not
place beverages or any other liquid-containing vessels on or near the
unit.
This unit is intended installation in a controlled environment
(temperature controlled, indoor area free of conductive contaminants).
Avoid installing the UPS in locations where there is standing or running
water, or excessive humidity.
Do not plug the UPS input into its own output.
Replace with the same type of
battery.
Press the power switch again.
Alarm buzzer UPS is overloaded.
beeps
continuously
when AC
supply is
normal.
Verify that the load ma tches the UPS
capability specified in the specs.
When power Ov erload of the UPS.
failure, backup Battery voltage is too
time is short. low.
Remove some noncritical load.
Comm un icat ion
los t be twee n
UPS an d
compu ter.
Charge battery 8 hours or more.
Battery defect .
Replace with the same type of
battery.
Software is not
installed properly.
Cable is not firml y
connected.
Check the setting of the software.
Internal battery voltage is 12Vdc. Sealed, lead-acid, 6 cells battery.
Connection to any other type of receptacle other than a two-pole, threewire grounded receptacle may result in shock hazard as well as violate
local electrical codes.
Solution
Check the USB cable is firml y
connected to the comp uter and
confirm the setting again.
Mains normal Breaker trips.
but yellow LED
Power cord is loose.
brinks.
Re set the breaker.
Re connect the powe r cord properly.
If any abnormal situations occur that are not listed above, please call for
service immediately.
Specification
Do not attach a power strip or surge suppressor to the UPS.
PRO-1100AVR
Do not attach non-computer-related items, such as medical equipment,
life-support equipment, microwave ovens, or vacuum cleaners to UPS.
110/120VAC or 220/230/240VAC
81-145VAC or 162-290VAC
To reduce the risk of overheating the UPS, do not cover the UPS' cooling
vents and avoid exposing the unit to direct sunlight or installing the
unit near heat emitting appliances such as space heater or furnaces.
50/60Hz (Auto Sensing)
Unplug the UPS prior to cleaning and do not use liquid or spray detergent.
Do not open or mutilate the battery or batteries. Release electrolyte is
harmful to the skin and eyes. It may be toxic.
Up to
A battery can present a risk of electrical shock and high short circuit
current. The following precautions should be observed when working
on batteries:
1) Remove watches, rings, or other metal objects from the hands.
2) Use tools with insulated handles.
3) Wear rubber gloves and boots.
4) Do not lay tools or metal parts on top of batteries.
5) Disconnect charging source prior to connecting or disconnecting
batteries terminal.
RJ11/RJ45(One In One Out)
350 x 146 x 160mm
13.8 x 5.7 x 6.3 in
8.0kgs / 21.16lbs
Servicing of batteries should be performed or supervised by personnel
knowledgeable of batteries and the required precautions. Keep
unauthorized personnel away from batteries.
When replacing batteries, replace with the same number and type of
sealed lead-acid battery. The maximum ambient temperature rating is
40 C.
During the installation of this equipment it should be assured that the
sum of the leakage currents of the UPS and the connected loads does
not exceed 3.5mA.
This pluggable type A equipment with battery already installed by the
supplier is operator installable and may be operated by laymen.
Attention, hazardous through electric shock. Also with disconnection
of this unit from the mains, hazardous voltage still may be accessible
through supply from battery. The battery supply should be therefore
disconnected in the plus and minus pole of the battery when maintenance
or service work inside the UPS is necessary.
The mains socket outlet that supplies the UPS shall be installed near
the UPS and shall be easily accessible.
Windows® 2000/2003/XP/Vista/2008, Windows® 7,
Linux, Unix, and MAC
Specification change without notice.
Product Warranty and Service Information:
For U.S. customers, please register your product at www.MarusonUSA.com.
For international customers, please contact your local authorized distributor
or e-mail [email protected] for assistance.