Selection Chart
Digital Soft Starters
The IMS2 offers a choice of soft start and soft stop profiles to ensure optimum control for all load types.
The unique torque control system gives more linear acceleration than standard constant current models.
IMS2 soft starters can be installed with or without a bypass contactor, and in three-wire or six-wire (inside delta) configuration.
FEATURES
IMS2
Starting
Constant current
Current ramp
Torque control
Kickstart
Stopping
Soft stop
Pump stop
Soft braking
Protection
Motor thermal model
Motor thermistor input
Phase imbalance
Phase sequence
Electronic shearpin
Undercurrent
Auxiliary trip input
Starter heatsink overtemperature
Excess start time
Supply frequency
Shorted SCR
Power circuit
Human Interface
Local pushbuttons
(Start, Stop, Reset, Local/Remote)
Numeric display
Remote input status LEDs
Phase indicator LEDs
Control Interface
Control inputs (3 x fixed, 1 x programmable)
Relay outputs (1 x fixed, 3 x programmable)
Analogue output (1 x programmable)
Serial output (1 x RS485)
Sundry
Current & Motor Temperature readout
Trip Log & Start Counter
Multiple function sets
Function lock, Password protection
Store/Restore function settings
Emergency Mode operation
Wall mount (models up to 253 A)
Adjustable bus bar configuration
Bypassing the soft starter during operation reduces heating while the motor is running, reducing the amount of ventialtion and
cooling required.
Protection functions operate even when bypassed
ü
ü
ü
ü
ü
ü
ü
ü
ü
ü
ü
ü
ü
ü
ü
ü
ü
ü
ü
External input/outputs for remote management
Fully programmable restart delay and auto-reset
Continuous Operation (Bypassed)
SCHEMATIC
IMS2 installed with bypass contactor (controlled by Run output)
AC53a
3-10:350
45°C
<1000m
K1M Bypass Contactor
Semiconductor Fuses (optional)
F1
L1
AC53a
3.5-15:345
45°C
<1000m
AC53a
4-20:340
45°C
<1000m
AC53a
4.5-30:330
45°C
<1000m
T1
L1B
L2
3 PHASE
SUPPLY
T2
TO MOTOR
L2B
L3
T3
L3B
E
C12 models
110 V
C45 models
+ 10
- 15 460 V
OR
230 V
OR
+ 10
- 15 575 V
C24 models
+ 10
- 15 400 V
A1
B1
+ 10
- 15
A2
+ 10
- 15
A3
B2
GND
B3
OR
+ 10
- 15 230 V
13
C23
ü
ü
ü
ü
START
STOP
CONTROL
SUPPLY
24
C32
33
C41
34
K1M
OUTPUT B
C42
41
C53
INPUT A
MOTOR
THERMISTOR
ü
OUTPUT A
23
RESET
ü
ü
ü
ü
ü
ü
ü
ü
14
C24
C31
ü
ü
ü
ü
(models above 302 A)
Approvals
5
Advanced soft start and soft stop control
C54
OUTPUT C
42
44
B4
B10
B5
B11
4-20 mA
OUTPUT
Ratings
Current Range
Supply Voltage
Supply Frequency
Control Voltage
Enclosure
Approvals
18A ~ 1574A, AC53a
200 ~ 690VAC
50/60Hz
110VAC / 240VAC / 440VAC
IP42 or IP54 up to 253A