2
Basic functions
Keys to press
Function
Call an extension
General internal call
Call on outside telephone line
Touch-tone telephone
R + da 401 a 408
R + 400
telephone number
Auto-dial on busy
Short number phone book
R55
R + 30 + short number
from 01 to 50
Repeat the last outside telephone number
R + 50
called
Answer a call
(extension/outside/door entry)
lift the receiver
Put a conversation on hold
R
(outside or door entry)
Put a conversation on hold and put through
(outside or door entry)
R + from 401 to 408
and hang up
Continuing a conversation put on hold
Open door lock
Switch on staircase light
Self-switch on outdoor station
Temporary unlock of locked prefixes
R
R7, with Pivot (
)
R8, with Pivot (
)
R61, with Pivot (
)
R + 97 + password + R
Activate “fast line” for data transmission
R + 91
Activating a relay
R + 99+1n
(n=relay number from 0 to 8)
Deactivating a relay
R + 99+0 n
(n=relay number from 0 to 8)
“Night” service
R + 312
Return to “day” service
R + 311
Audio room monitor
Call capture with answering machine
R + 920
R + extension No. where the
answering machine is installed
from 401 to 403
Terraneo
3
GENERAL CONTENTS
1
INTRODUCTION
WARNINGS FOR THE INSTALLER
PACKAGE CONTENT
GENERAL VIEW
DESCRIPTION
2
2.1
2.2
2.3
2.4
2.5
2.6
2.7
2.8
2.9
3
3.1
3.2
3.3
3.4
3.5
4
4.1
4.2
4.3
4.4
4.5
4.6
4.7
4.8
4.9
5
5.1
5.2
6
6.1
6.2
6.3
6.4
6.5
6.6
6.7
pag.
pag.
pag.
pag.
5
5
6
7
pag.
pag.
pag.
pag.
pag.
pag.
pag.
pag.
pag.
8
8
8
8
9
10
10
10
10
pag.
pag.
pag.
pag.
pag.
11
11
12
12
13
pag.
pag.
pag.
pag.
pag.
pag.
pag.
pag.
pag.
14
15
16
17
18
19
20
21
22
pag.
pag.
23
25
pag.
pag.
pag.
28
29
29
pag.
pag.
30
30
pag.
31
pag.
31
MAIN FUNCTIONS
BASIC CONFIGURATION
PERSONALISING THE SERVICES
MUSIC WHILE ON HOLD
HOUSE-AUTOMATION SCENARIOS
DOOR ENTRY CALLS
EXTRA DOOR LOCKS
OUTSIDE MUSIC SOURCE
COMMAND STAIRCASE LIGHT FROM THE OUTDOOR STATION PUSHBUTTON
CALL REPEATER FOR EXTRA BELL
PROGRAMMING
BASIC CONFIGURATION
PROGRAMMING FUNCTIONS BY PERSONAL COMPUTER
ACCESS TO PROGRAMMING THROUGH EXTENSIONS
REINITIALISATION COMMANDS (RESET)
DIRECT ACCESS TO THE OUTSIDE TELEPHONE LINE
SIMPLIFIED PROGRAMMING
PROGRAMMING NUMBER AND TYPE OF OUTSIDE TELEPHONE LINE
SETTING ANSWERING MACHINE AND MODEM/FAX
AUTOMATIC ANSWER
PROGRAMMING THE RELAYS
CALL REPEATER FUNCTION FOR EXTRA BELL
DISABLING TELEPHONES FROM RECEIVING INCOMING TELEPHONE CALLS
DISABLING TELEPHONES FROM MAKING OUTGOING TELEPHONE CALLS
DISABLING TELEPHONES FROM RECEIVING DOOR ENTRY CALLS
DISABLING TELEPHONES FROM PERFORMING DOOR ENTRY SERVICES
PROGRAMMATION THE TYPE APPLICATIONS
USING THE TYPE APPLICATIONS
EXAMPLES OF TYPE APPLICATIONS
ADVANCED PROGRAMMING
PROGRAMMING TELEPHONE LINE TYPE
CHARACTERISATION OF AN EXTENSION (TELEPHONE, FAX OR MODEM ...)
PROGRAMMING RELAYS FOR STAIRCASE LIGHT FUNCTION
ASSIGNING A RELAY TO THE STAIRCASE LIGHT PUSHBUTTON OF
THE OUTDOOR STATION
PROGRAMMING THE CALL REPEATER FUNCTION FOR EXTRA BELL
PROGRAMMING REMOTELY OPERATED RELAYS AS MONOSTABLE
ACTUATORS ONLY FROM EXTENSIONS
PROGRAMMING REMOTELY OPERATED RELAYS AS BISTABLE ACTUATORS
ONLY FROM EXTENSIONS
PABX 18D
4
6.8
PROGRAMMING REMOTELY OPERATED RELAYS AS MONOSTABLE
ACTUATORS FROM EXTENSIONS AND TELEPHONE LINE
6.9 PROGRAMMING REMOTELY OPERATED RELAYS AS BISTABLE
ACTUATORS FROM EXTENSIONS AND TELEPHONE LINE
6.10 LENGTH OF THE CALL SIGNAL FROM THE OUTDOOR STATION
6.11 PROGRAMMING THE OUTSIDE MUSIC SOURCE
6.12 PROGRAMMING THE R (OR FLASH KEY) RECOGNITION TIMES
7
7.1
7.2
7.3
7.4
7.5
8
8.1
8.2
8.3
8.4
8.5
8.6
8.7
9
9.1
9.2
9.3
9.4
9.5
9.6
9.7
pag.
32
pag.
pag.
pag.
pag.
32
33
33
33
pag.
pag.
pag.
pag.
34
35
36
36
pag.
38
pag.
pag.
pag.
pag.
pag.
pag.
pag.
40
40
41
42
43
44
45
pag.
pag.
pag.
pag.
pag.
pag.
pag.
53
53
54
55
55
56
82
pag.
83
pag.
pag.
pag.
86
87
88
pag.
pag.
pag.
pag.
pag.
89
90
92
92
94
pag.
pag.
95
96
HOUSE-AUTOMATION SCENARIO PERSONALISATIONS
ENABLING TELEPHONES FOR INCOMING AND OUTGOING CALLS
PROGRAMMING REMOTE ACTIVATION AND RECOGNITION OF FAX/MODEM
PROGRAMMING WAIT RINGS
MANAGEMENT OF FAX AND MODEM
TRANSFERRING THE DOOR ENTRY CALL TO OUTSIDE TELEPHONE LINE
(DOSA SERVICE)
CALL LOCK MANAGEMENT
LOCK PREFIX 00
LOCK PROGRAMMED PREFIXES
ENTERING PREFIXES TO BE LOCKED
ENTERING PREFIXES TO BE UNLOCKED FOR TELECOM
ENTERING PREFIXES OF OTHER CARRIERS
PREFIXES TO BE UNLOCKED FOR OTHER CARRIERS
EXAMPLES OF ACTIVATION OF LOCKS ON OUTGOING DIALLING
INSTALLATION
CABLES AND CONNECTIONS
INSTALLING PABX EXCHANGE
COMPOSITION OF THE TELEPHONES + VIDEO SECTION
INSTALLING THE TELEPHONE + WALL-MOUNTED VIDEO SECTION
INSTALLING THE TELEPHONE + TABLE-MOUNTED VIDEO SECTION
CONNECTION DIAGRAMS
SYSTEM TYPE APPROVAL
10 SUMMARY TABLES
11 EXPANDABILITY
11.1
11.2
11.3
11.4
11.5
11.6
11.7
11.8
VIDEO DISTRIBUTOR (ITEM 335918)
VIDEO EXPANDER (ITEM 335925)
RELAY EXPANSION MODULE (ITEM 335912)
DOOR ENTRY INTERFACE MODULE FOR ANALOG AND DIGITAL SYSTEMS
(ITEM 335910)
DOOR ENTRY INTERFACE MODULE FOR THE 2-WIRE SYSTEM (ITEM 346810)
DEDICATED SPEAKER UNIT FOR PABX (ITEM 335902)
INSTALLING THE SPEAKER UNIT
ACCESSORY FOR PROGRAMMING FROM PC (ITEM 335919)
12 TECHNICAL DATA
12.1 TECHNICAL CARD
12.2 STANDARDS REFERENCES
Terraneo
1
5
INTRODUCTION
WARNINGS FOR THE INSTALLER
Before proceeding with the installation read this manual carefully, because the guarantee will be
automatically cancelled as a result of negligence, incorrect operation, improper use or tampering with the
circuit by unauthorised people.
Only specialised personnel should perform the installation and maintenance operations.
Use insulated screwdrivers and do not touch the terminals directly to avoid electro-static shocks.
Do not install the exchange or telephones connected to it near water (e.g. laundries, swimming pools,
damp surfaces) or heat sources (radiators, stoves, cookers).
Do not install the exchange in places which are very dusty or where there are corrosive vapours.
Room temperature from 0 to 40°C, relative humidity from 20% to 80%, not condensing.
When the installation is complete perform the following operations:
1.
Perform all the tests described in section 9.7 “SYSTEM TYPE APPROVAL” carefully;
2.
Check all the functions described in the “MAIN FUNCTIONS” chapter;
3.
Perform the necessary programming described in the programming chapters, remembering to
make a note of all the programming data in the summary table; also when the programming is finished,
check correct operation of the exchange and all the telephones connected to it again.
PACKAGE CONTENTS
The porter exchange package contains:
PABX exchange item 335818
user instruction manual
installer instruction for use manual
Part. T5
Terraneo
Telephone exchange
PABX 18DTerr
Tele
an
phone
exchan eo
PABX ge
18D
843A
Part. T5
852A
05/02 - PC
05/02
- PC
Part. T5842A
Part. T5852A
335818
35818
PABX 18D
1
6
INTRODUCTION
GENERAL VIEW
3
1
2
PRI
C
230V~ 50Hz
1
NO
6A
2A
(230V~ 50Hz)
M
COS
a
= 0,5
1
2
b a
2
3
b a
3
4
ba
4
5
b a
5
6
b a
6
b a
7
8
7
8
ba
b
PC
FAX
spa
PABX 18D cod. 335818
230V
335818
15% 0,15 A 50 Hz
Patent Pending
AUX
EXP
a
4
5
6 7
U1
3 4 M PT R
b
8
9
10
11
12
1 – 230V a.c. power supply
2 – Staircase light relay (actuation/remote operation)
3 – Extensions from 401 to 408. Connection 1 for telephones 401: emergency telephone line 1 and
possibility of “fast line” programming for fax or modem.
4 – PC connector for exchange programming.
5 – Connector for back-up battery (function not available).
6 – Green led 230 V a.c. ON.
7 – Analog telephone line.
8 – Earth terminal to protect telephone lines inside the exchange.
9 – Red led to check correct operation.
10 – Speaker unit of the door entry system or riser interface, connection by interface of the 2-wire
system or video distributor
11 – Relay for actuations and remote operations, connection for interface of the 2-wire system or video
distributor
12 – Music while on hold from outside source.
Terraneo
1
7
INTRODUCTION
DESCRIPTION
The telephone exchange can make systems for communication in homes and offices combining the
telephone services with the door entry services.
In the basic version it can manage 1 analog telephone line, 2 door entry calls and up to 8 telephones.
Another telephone can be connected in parallel to each telephone.
Commands such as opening the door lock or switching on the staircase light can be activated by telephone.
Or by purchasing the relay expansion module (item 335916) extra devices can be operated, e.g. opening
the driveway gate or other.
The Distributor and video Expander accessories can connect up to 8 video door entry telephones, (as an
alternative to the 8 telephones which can be directly connected to the exchange), 3 outdoor video door
entry stations and a surveillance camera, offering great simplification in making the system.
Because of its ease of use and flexible services the exchange is particularly suitable for use in homes,
shops or offices. Its full compatibility with both pulse-dial telephones (such as dial telephones) and touchtone telephones with keypad, is guaranteed.
The telephones can thus be of any type, including two-standard telephones (pulse-dial/touch-tone),
cordless telephones and devices for the office (fax, answering machines and modem).
With pulse-dial telephones not all the exchange services and performance can be used.
1..............
2..............
3..............
EXTENSION
4..............
5..............
6..............
7..............
8..............
9..............
1
2
1..............
2..............
3..............
4..............
5..............
6..............
7..............
8..............
9..............
1
2
3
M1
4
5
6
R
7
8
9
RP
0
FAX
MODEM,
ANSWERING
MACHINE
PRI
PABX
TELEPHONE
EXCHANGE
-
230V~50Hz
C
NO
6A
2A
a1b a2b a3b a4b a5b a6b a7b a8b
(230V~50Hz)
M
cos g = 0.5
FAX
spa
PABX 18D cod. 335818
230V
335818
15% 0,15 A 50 Hz
Patent Pending
E X P.
- +
AUX
a U1b
3 4 M P T R
TELEPHONE SYSTEM
M1
4
5
6
R
7
8
9
RP
0
EXTENSION
3
OUTDOOR
ENTRY
STATION
PABX 18D
2
MAIN FUNCTIONS
2.1
MAIN CONFIGURATION
8
The PABX telephone exchange is supplied with a “basic configuration”, corresponding to the following:
as a base the programming, temporary unlock and remote activation password is: 1 2 3 4;
the exchange is set up for touch-tone telephone lines;
the answering machine, modem or fax must be programmed;
house-automation scenario 1 is active with the following settings:
all the extensions are enabled to receive incoming calls on the outside telephone line;
all the extensions are enabled for outgoing communications on the outside telephone line;
all the extensions are enabled for the door entry services (call, door lock, staircase light, self-switching
on);
all the extensions are enabled to activate the actuation relays;
house automation scenario 2 is for the night service.
direct access to the outside telephone line is enabled.
2.2
PERSONALISING THE SERVICES
The installer can change the basic configuration dialling codes manually by means of touch-tone telephones
or personal computer using the TIPBX software. A special password, which prevents programming by
unauthorised persons, is saved permanently until the user changes it again.
Personalisation is not possible with pulse-dial telephones.
2.3
MUSIC WHILE ON HOLD
The exchange is already programmed with music while on hold containing the message “please hold the
line”.
Any outside musical source can be used as an alternative to this (see section 2.7).
2.4
HOUSE-AUTOMATION SCENARIOS
At certain times of the day it may be necessary to divert all the incoming calls to the office telephones to
the home telephones, or not receive calls on some telephones, e.g. the telephones of the night area or
study.
The exchange satisfies this requirement with the creation of 5 different house-automation scenarios,
or 5 different modes of operation which can be activated with a simple command.
The exchange is supplied with house-automation scenario 1 active and house-automation scenario 2
programmed in night service. To divert all the calls on extensions 401 and 402, just activate houseautomation scenario 2 while to return to initial exchange conditions reactivate scenario 1. The other 3
basic house-automation scenarios are identical to scenario 1 and can be personalised to fulfil the most
demanding requirements (see “Personalising house-automation scenarios” chapter).
Terraneo
2
2.5
9
MAIN FUNCTIONS
DOOR ENTRY CALLS
The telephone exchange can manage up to 2 separate door entry calls, which can be addressed separately
on 2 telephone units.
If activated the DOSA service can put through a door entry call from an outdoor station to a telephone
number, both landline and mobile. This service is also available even when you are not at home.
EXAMPLE OF A SYSTEM WITH TWO DOOR ENTRY CALLS
1..............
2..............
3..............
4..............
5..............
6..............
7..............
8..............
9..............
1
2
3
4
5
6
R
7
8
9
RP
M1
Home
door entry call 2
0
Outdoor entry
station
1..............
2..............
Office
door entry
call 1
3..............
4..............
5..............
6..............
7..............
8..............
9..............
1
2
3
4
5
6
R
7
8
9
RP
M1
0
PRI
-
230V~50Hz
C
NO
6A
2A
a1b a2b a3b a4b a5b a6b a7b a8b
(230V~50Hz)
M
cos g = 0.5
FAX
spa
PABX 18D cod. 335818
230V
335818
15% 0,15 A 50 Hz
Patent Pending
EXP .
- +
AUX
a U1b
Door entry call 1
3 4 M P T R
Door entry call 2
Telephone system
PABX 18D
2
2.6
10
MAIN FUNCTIONS
EXTRA DOOR LOCKS
The relay inside the exchange can be used to command extra door locks or an automatic gate (if there is
no switching on staircase light and after special programming) or a relay of accessory item 335916.
2.7
OUTSIDE MUSIC SOURCE
An outside music source with input voltage maximum 1 V p.p. can be connected to the
disable the internal music source by programming.
2.8
terminals;
COMMAND STAIRCASE LIGHT FROM OUTDOOR STATION PUSHBUTTON
The speaker unit staircase light key is, as base, associated with the exchange relay; this relay is thus
activated both by the telephone
key (STAIRCASE LIGHT) or by the speaker unit staircase light
key. Switching on from the outdoor station can however be disabled by programming (see the “Assigning
a relay to the staircase light pushbutton of the outdoor station” section).
2.9 CALL REPEATER FOR EXTRA BELL
This function can command a relay when a telephone receives a call (from outside telephone line, door
entry unit or extension).
The internal relay can be associated with the PABX (staircase light) by programming (see call repeater
for extra bell function section) or the outside relays on the extra modules item 335916 can be associated
with an extension.
The “call repeater for extra bell” function is recommended to make the bell of a telephone in noisy rooms
louder.
Terraneo
3
11
PROGRAMMING
Programming can be performed in two different ways:
Manually typing codes on the keypads of the touch-tone telephones.
The programming is not possible with pulse-dial telephones.
By means of a personal computer, using the dedicated software which can be downloaded free of
charge from the www.bticino.it Internet site.
3.1
BASIC CONFIGURATION
When switching on for the first time, the exchange is programmed with the following basic configuration:
Italian telephone network
active touch-tone telephone line
as a base the programming, remote activation and temporary unlock password is: 1 2 3 4
all the extensions are programmed as extension telephones: specific programming is required for the
connection of FAX, answering machines or modem
the door entry call signal lasts for 30 seconds
the staircase light is switched on (with
or R8) by means of the exchange relay in monostable
mode for 2 seconds. The relay can be used for other services instead of switching on the staircase
light by means of specific programming.
3.2
PROGRAMMING FUNCTIONS BY PERSONAL COMPUTER
All the functions can be programmed by Personal Computer; for this type of programming the exchange
must be connected with a PC by means of interface item 335919. The interface is made up of a 1.5 m
multi-cable with a connector to be put into the exchange IOIOI port and another connector to be put into
the Personal Computer (COM1 – COM2).
Then use the “TIPBX” software which can be downloaded free of charge from the www.bticino.it Internet
site in the technical software section.
For systems including the Video Distributor item 335918 th]ƒ[oftware must be version 3.1 or later.
There is no need to enter the password when programming by computer. This allows reprogramming the
exchange even if the password has been forgotten.
Warning: When the programming is complete take the cable out of the exchange IOIOI port.
Never leave the cable in the IOIOI port when switching the exchange on. If you do the red LED will
flash.
PABX 18D
3
3.3
12
PROGRAMMING
ACCESS TO PROGRAMMING THROUGH EXTENSIONS
Lift the receiver
R
Press ke
Type:
, you will hear the start-dialling tone.
#
#
Dial the password (e.g. base
1
2
3
4
)
- If the password is correct you will hear a start-dialling tone
- If the password is not correct you will hear a time-out tone. In this case hang up and repeat the procedure
described above.
After the start-dialling tone proceed with the programming.
The programming can be performed from any extension.
3.4
REINITIALISATION COMMANDS (RESET)
To reset the factory values for some or whole groups of parameters use the following commands after
performing the access programming procedure:
general reset:
9
9
9
9
9
#
wait for the confirmation tone.
Warning: The command modifies the Password returning it to the initial value 1 2 3 4 and cancels
the short number table, the programmed locks tables and the carrier table.
For the other setting see the description of the basic configuration.
House-automatic scenario 1 is thus reset.
Telephone line parameters: reinitialisation of the telephone line parameters (length of R key or
flash recognition time,…);
1
9
9
9
9
#
fax/modem: Cancelling Fax/Modem and answering machine programming.
3
9
9
9
9
#
Terraneo
3
3.5
13
PROGRAMMING
DIRECT ACCESS TO THE OUTSIDE TELEPHONE LINE
This command can activate or deactivate direct access to the outside telephone line of all the telephones
enabled for outgoing calls.
With the “direct access to the outside telephone line” activated (basic configuration), connection to the
telephone line occurs by just lifting the receiver of the enabled telephones.
If the mode is deactivated, lifting the receiver of the enabled telephones you will hear the internal dialling
tone. To connect with the outside telephone line use codes 0 or 91.
Warning: only with touch-tone telephones. The programming is valid for all the telephones.
Programming to deactivate direct access
1.
lift the receiver
2.
press the R key, wait for the start-dialling tone
3.
dial 980
4.
dial the password (4 numbers) and wait for the dial tone
5.
dial 10 to deactivate the service
6.
confirm by pressing the R key
7.
after receiving the confirmation tone hang up.
Programming to activate direct access
1.
lift the receiver
2.
dial 980
3.
dial the password (4 numbers) and wait for the dial tone
4.
dial 11 to activate the service
5.
composer le numéro 11 pour activer le service
6.
confirm by pressing the R key
7.
after receiving the confirmation tone hang up.
Note: the “General reset 99999” command resets the exchange with direct access to the telephone line
activated.
PABX 18D
4
14
SIMPLIFIED PROGRAMMING
The group of “Macrocommands” has been developed for simplified exchange programming. These
commands also reinitialise the basic values of some parameters, as reported for each command.
Before entering the macrocommands the programming access procedure must be performed.
After the programming with macrocommands the exchange must be switched off and back on.
4.1
PROGRAMMING TYPE OF OUTSIDE TELEPHONE LINE
This must be performed when the two lines are pulse-dial or when only one of the two telephone lines is
used.
The commands must be performed after the programming access procedures (see section 3.4).
Type of line
Telephone
line 1
*
71
*
01
1
0
0
0
0 No line
1 Touch-tone line
2 Pulse-dial line
Example: activating the telephone line as pulse-dial
Lift the receiver
Press the
Type:
#
R
key, you will hear the start-dialling tone
#
Dial the password (e.g. base
1
2
3
4
)
After the start-dialling tone type the Macrocommand:
7
1
0
After hearing the confirmation tone hang up
1
2
0
0
0
#
#
Terraneo
4
4.2
15
SIMPLIFIED PROGRAMMING
SETTING ANSWERING MACHINE AND MODEM/FAX
Devices such as answering machine, Fax or modem must be so programmed that the exchange can
recognise them. Using the macrocommand the devices can only be positioned on the outlets indicated in
the table.
Detailed programming is necessary to program the devices on other extensions (see personalisation of
house-automation scenarios chapter).
Type of device
on 402
Type of device
on 401
*
73
*
0
0
Enter for each type of device
0 Telephone
1 Answering machine
2 Fax
3 Modem
4 Answering machine+Fax
5 Modem Fax
6 Answering machine+Modem Fax
9 Does not change the previous programming
Example: telephone on extension 401 and fax on extension 402:
Lift the receiver
Press the
Type:
#
R
key, you will hear the start-dialling tone
#
Dial the password (e.g. base
1
2
3
4
)
After the start-dialling tone type the Macrocommand:
7
3
After hearing the confirmation tone hang up
0
2
#
PABX 18D
4
4.3
16
SIMPLIFIED PROGRAMMING
AUTOMATIC ANSWER
This macrocommand can activate the Fax or Modem tone remote activation and recognition services.
The programming with this command is valid for all the house-automation scenarios.
Telephone
line 1
*
74
*
0
0
0
#
0
0 Not enabled
4 Remote operation
5 Recognition Fax or Modem tone
9 Does not change the previous programming
Example: line 1 enabled for remote operation
Lift the receiver
Press the
Type:
#
R
key, you will hear the start-dialling tone
#
Dial the password (e.g. base
1
2
3
4
)
After the start-dialling tone type the Macrocommand:
7
4
After hearing the confirmation tone hang up
4
0
0
0
#
Terraneo
4
4.4
17
SIMPLIFIED PROGRAMMING
PROGRAMMING THE RELAYS
This programming must be performed to define the mode of operation and/or the timing of the remotely
operated relays.
The command must be performed after the programming access procedure.
Relay number
*
75
*
Operation
from 0 to 7
from 0 to 8
0
1
2
3
4
5
6
7
8
After the sequence
75
program several relays.
several pairs of numbers (relay number and operation) can be entered to
Note: the relay number = 0 identifies the internal relay in the exchange
Example: relay 0 remotely operated 2 seconds, relay 1 remotely operated On/Off
Lift the receiver
Press the
Type:
#
R
#
0 remotely operated 2 seconds
1 remotely operated 3 minutes
2 remotely operated On/Off
3 not remotely operated 2 seconds
4 not remotely operated 3 minutes
5 not remotely operated On/Off
6 Staircase light 2 seconds
7 Staircase light 3 minutes
exchange relay
relay 1 on module 1
relay 2 on module 1
relay 3 on module 1
relay 4 on module 1
relay 1 on module 2
relay 2 on module 2
relay 3 on module 2
relay 4 on module 2
key, you will hear the start-dialling tone
#
1
Dial the password (e.g. base
2
3
4
)
After the start-dialling tone type the Macrocommand:
7
5
After hearing the confirmation tone hang up
0
0
1
2
#
PABX 18D
4
4.5
18
SIMPLIFIED PROGRAMMING
CALL REPEATER FUNCTION FOR EXTRA BELL
The table below gives the associations between relay and extension to be considered when installing an
extra bell.
Number of the relay with which an
extension is associated
*
75
*
from 0 to 8
0
1
2
3
4
5
6
7
8
=
=
=
=
=
=
=
=
=
8
exchange relay = 405 telefono 5
relay 1
= 401 telephone 1
relay 2
= 402 telephone 2
relay 3
= 403 telephone 3
relay 4
= 404 telephone 4
relay 5
= 405 telephone 5
relay 6
= 406 telephone 6
relay 7
= 407 telephone 7
relay 8
= 408 telephone 8
Example: extra bell connected to relay 3 associated with extension 403:
Lift the receiver
Press the
Type:
#
R
key, you will hear the start-dialling tone
#
Dial the password (e.g. base
1
2
3
4
)
After the start-dialling tone type the Macrocommand:
7
5
After hearing the confirmation tone hang up
3
8
#
#
Terraneo
4
4.6
19
SIMPLIFIED PROGRAMMING
DISABLING TELEPHONES FROM MAKING OUTGOING TELEPHONE
CALLS
This personalisation defines which telephones can use the outside telephone line to make outgoing calls.
In basic programming conditions all the extensions are enabled to use the outside line.
The personalisation procedure is the following:
*
*
*
Link with house-automation scenario X (from 1 to 5) which can be activated with command
31X (from 311 to 315)
(see “Personalisation of house-automatic scenarios” chapter in the installer manual)
*
Telephone
number
from 01 to 08
Line 1
5
1
01
3
5
1
01
3
*
*
0
0
0
0
#
Disabling
telephone 1
1
0
0
0
#
Reenabling
telephone 1
Example: disabling telephone 8 from receiving incoming telephone calls.
Lift the receiver
Press the
Type:
R
key, you will hear the start-dialling tone
#
#
Dial the password (e.g. base
1
2
3
4
)
After the start-dialling tone type the Macrocommand:
5
1
0
8
3
After hearing the confirmation tone (3 short tones) hang up.
0
0
0
0
#
PABX 18D
4
4.7
20
SIMPLIFIED PROGRAMMING
DISABLING TELEPHONES FROM MAKING OUTGOING TELEPHONE
CALLS
This personalisation defines which telephones can use the outside telephone line to make outgoing calls.
In basic programming conditions all the extensions are enabled to use the outside line.
The personalisation procedure is the following:
*
*
*
Link with house-automation scenario X (from 1 to 5) which can be activated with command
31X (from 311 to 315)
(see “Personalisation of house-automatic scenarios” chapter in the installer manual)
*
Telephone
number
from 01 to 08
5
1
01
2
5
1
01
2
Line 1
*
*
0
0
0
0
#
Disabling
telephone 1
1
0
0
0
#
Reenabling
telephone 1
Example: disabling telephone 04 from making outgoing telephone calls.
Lift the receiver
Press the
Type:
R
key, you will hear the start-dialling tone
#
#
Dial the password (e.g. base
1
2
3
4
)
After the start-dialling tone type the Macrocommand:
5
1
0
4
2
After hearing the confirmation tone (3 short tones) hang up.
0
0
0
0
#
Terraneo
4
4.8
21
SIMPLIFIED PROGRAMMING
DISABLING TELEPHONES FROM RECEIVING DOOR ENTRY CALLS
This personalisation defines which telephones can receive calls from the outdoor station.
In basic programming conditions all the telephones can receive door entry calls.
When there is an answering machine (modem or fax) it is useful to disable the receiving of door entry
calls.
The personalisation procedure is the following:
*
*
*
*
*
Link with house-automation scenario X (from 1 to 5) which can be activated with command
31X (from 311 to 315)
(see “Personalisation of house-automatic scenarios” chapter in the installer manual)
*
Telephone
number
from 0 to 16
5
1
01
0
5
1
01
0
5
1
01
0
5
1
01
0
PUSHBUTTON 2
*
*
*
*
1
#
Enabling to the call
from only pushbutton 1
2
#
Enabling to the call
from only pushbutton 1
3
#
Disabling telephone 1
0
# Reenabling telephone 1
PUSHBUTTON 1
Example: disabling telephone 8 for video door entry calls
Lift the receiver
Press the
Type:
#
R
key, you will hear the start-dialling tone
#
1
Dial the password (e.g. base
2
3
4
)
After the start-dialling tone type the Macrocommand:
5
1
0
8
0
After receiving the confirmation tone (3 quick tones) hang up.
3
#
PABX 18D
4
4.9
22
SIMPLIFIED PROGRAMMING
DISABLING TELEPHONES FROM PERFORMING DOOR ENTRY SERVICES
This personalisation defines which telephones can open the electric door lock, switch on the staircase
lights or auto-switch on the outdoor station (door entry services).
In basic programming conditions all the telephones can perform the door entry services.
The personalisation procedure is the following:
*
Link with house-automation scenario X (from 1 to 5) which can be activated with command
31X (from 311 to 315)
(see “Personalisation of house-automatic scenarios” chapter in the installer manual)
Telephone
number
from 0 to 16
*
*
*
5
1
2
01
5
1
2
01
*
*
0
# Disabling telephone 1
1
# Reenabling telephone 1
Example: disabling telephone 04
Lift the receiver
Press the
Type:
#
R
key, you will hear the start-dialling tone
#
1
Dial the password (e.g. base
2
3
4
)
After the start-dialling tone type the Macrocommand:
5
1
2
0
4
After receiving the confirmation tone (3 quick tones) hang up.
0
#
Terraneo
5
23
PROGRAMMING THE TYPE APPLICATIONS
5.1
USING THE TYPE APPLICATIONS
This macrocommand can program the PABX exchange according to certain pre-set functions called
“type applications”.
The type applications available are:
Management of fax and modem
Relay 1 programmed as remotely operative
Answering machine management
To select the type application:
Type
applications
*
76
*
xx
#
Where XX is the code to set to call the type application:
XX
00
01
02
Type applications
Management of fax and modem (example 1 sect. 5.2)
Relay 1 programmed as remotely operative from outside telephone line (example 2 sect. 5.2).
Answering machine management (example 3 sect. 5.2)
Note: after this programming there is no need to switch off the power to the exchange.
PABX 18D
5
5.1
24
PROGRAMMING THE TYPE APPLICATIONS
USING THE TYPE APPLICATIONS
Example: programming the type application for a system with one division with answering
machine setting corresponding to code 02 (example 3 of the following chapter).
Lift the receiver
Press the
dialling tone
R
#
#
2
1
3
key, you will hear the start-
Type
4
Dial the password (base1234).
Wait for the start-dialling tone.
7
6
0
2
#
Type the command corresponding to
the type application required.
After hearing the confirmation tone hang up
(wait for about 40 seconds).
Note: after the following programming there is no need to switch off the power to the exchange.
Terraneo
5
5.2
25
PROGRAMMING THE TYPE APPLICATIONS
EXAMPLES OF TYPE APPLICATIONS
Example 1 – “Fax and Modem management” type applications
The exchange can automatically recognise the FAX or MODEM tones from the outside telephone line
and send the call to the extensions programmed as FAX or MODEM.
Modem management is programmed on extension 1, for the incoming calls from outside telephone line 1.
The programming is valid for all the house-automation scenarios. To disable door entry calls on extension
1 refer to the “Disabling telephones for door entry calls” section, remembering that the command only
acts on the house-automation scenario programmed.
PRI
C
230V~ 50Hz
NO
6A
2A
(230V~ 50Hz)
M
COS
a
= 0,5
1
b a
2
b a
3
ba
4
b a
5
b a
6
b a
7
ba
8
b
Modem 401
PC
FAX
spa
a
b
PABX 18D cod. 335818
230V
335818
FAX
15% 0,15 A 50 Hz
Patent Pending
Telephone 402
AUX
EXP
1..............
a
U1
b
2..............
3 4 M PTR
3..............
4..............
5..............
6..............
7..............
8..............
telephone line
a
b
9..............
1
2
3
4
5
6
R
7
8
9
RP
M1
0
Telephone 403
1..............
2..............
3..............
4..............
5..............
6..............
7..............
8..............
a
b
9..............
1
2
3
M1
4
5
6
R
7
8
9
RP
0
76 * 00 #
*
The automatic recognition of the Fax or Modem tone has been set on the telephone line:
to activate this type application use the command:
(
74
5999 # macrocommand to activate the individual function).
A modem has been set on extension 401;
( 73 39 # macrocommand to activate the individual function).
PABX 18D
5
26
PROGRAMMING THE TYPE APPLICATIONS
Example 2 – “Programming remote activation” type application
Remote activation is programmed for incoming calls from telephone line. Relay 1 is enabled for remote
activation and programmed as monostable with activation 2 seconds. The programming is valid for all the
house-automation scenarios.
BASE RELAY
PRI
C
230V~ 50Hz
NO
6A
2A
(230V~ 50Hz)
M
COS
1
a
= 0,5
b a
2
b a
3
ba
4
b a
5
b a
6
b a
7
ba
8
b
PC
FAX
spa
PABX 18D cod. 335818
230V
335818
15% 0,15 A 50 Hz
Patent Pending
AUX
EXP
a
U1
3 4 M PTR
b
Telephone line
12V~ M P T T1
IN
OUT
spa
PABX 28D cod. 335916
335916
max
16A
230V~
C C 1 2 3 4
RELAY 1
CONTACT
to activate this type application use the command:
6A
2A
M
COS
ACTUATOR
RELAY
* 76 * 01 #
Relay 1 has been programmed for remote activation;
75
B9743A
9906 6
C C 1 2 3 4
Remote activation has been set on telephone line.
( 74 9499 # macrocommand to activate the individual function).
(
= 0,5
10 # macrocommand to activate the individual function).
Terraneo
5
27
PROGRAMMING THE TYPE APPLICATIONS
Example 3 – “Answering machine” type applications
The answering machine is programmed on extension 2. The programming is valid for all the houseautomation scenarios. To disable door entry calls on extension 1 refer to the “Disabling telephones for
door entry calls” section, remembering that the command only acts on the house-automation scenario
programmed.
PRI
C
230V~ 50Hz
NO
6A
2A
(230V~ 50Hz)
M
COS
a
= 0,5
1
b a
2
b a
3
ba
4
b a
5
b a
6
b a
7
ba
8
Telephone 401
b
PC
FAX
1..............
spa
PABX 18D cod. 335818
230V
2..............
a
b
335818
3..............
15% 0,15 A 50 Hz
4..............
7..............
5..............
8..............
6..............
9..............
M1
R
RP
1
2
3
4
5
6
7
8
9
0
Patent Pending
AUX
EXP
a
U1
b
3 4 M PTR
Telephone line
Messagerie 402
a
b
SEGRETERIA
TELEFONICA
Telephone 403
1..............
2..............
3..............
4..............
5..............
6..............
7..............
8..............
a
b
to activate this type application use the command:
* 76 * 02 #
An answering machine has been set on extension 402:
( 73 91 # macrocommand to activate the individual function).
9..............
1
2
3
M1
4
5
6
R
7
8
9
RP
0
PABX 18D
6
28
ADVANCED PROGRAMMING
To set just one parameter without automatically reinitialising other values, as happens with
macrocommands, perform the advanced programming described below.
All the commands described in this chapter can only be sent to the exchange after performing the
programming access procedure described in section 3.3.
6.1
PROGRAMMING TELEPHONE LINE TYPE
This must be performed when the line is pulse-dial
Lift the receiver.
Press the
Type:
#
R
key, you will hear the start-dialling tone
#
Dial the password (e.g. base
1
2
3
4
)
If the telephone line is touch-tone, type:
2
0
0
0
2
1
0
0
0
#
0
2
2
0
0
0
#
If the telephone line is pulse-dial, type:
2
0
0
After receiving the confirmation tone, hang up.
Terraneo
6
29
ADVANCED PROGRAMMING
6.2
CHARACTERISATION OF AN EXTENSION (TELEPHONE ANSWERING
MACHINE, FAX OR MODEM)
Any extension can be characterised as fax, answering machine etc.
Extension
from 0 to 16
*
3
01
00
Answering
machine
0 absent
0 absent
0 absent
1 present
1 present
1 present
0
0
0
*
Fax
Modem
0
0
#
0
Example: to indicate that there is an answering machine on extension 1, dial:
3
6.3
0
1
0
0
1
0
0
0
0
0
#
PROGRAMMING RELAYS FOR STAIRCASE LIGHT FUNCTION
The relay inside the exchange is already set up as base as staircase light commanded by the
button; any other relays (item 335916) can however be programmed as staircase light.
Staircase light function
Relay identification
number
*
200
*
04
04
22
25
28
31
34
37
40
43
=
=
=
=
=
=
=
=
=
internal relay 0
relay 1
relay 2
relay 3
relay 4
relay 5
relay 6
relay 7
relay 8
Timing
3
0
0=
1=
3=
4=
5=
6=
7=
8=
2 seconds
10 seconds
30 seconds
1 minute
3 minutes
10 minutes
30 minutes
60 minutes
Example: to enable relay 3 for the staircase light function with 2-second timing, dial:
2
0
0
2
8
To reset the initial condition for internal relay 0 dial sequence
3
20004
0
#
30 #
#
PABX 18D
6
30
ADVANCED PROGRAMMING
6.4
ASSIGNING A RELAY TO THE STAIRCASE LIGHT PUSHBUTTON OF
THE OUTDOOR STATION
It is valid for all the house-automation scenarios.
Relay
identification
number
(see table
at the side)
Disabling/Enabling the
staircase light button
of the outdoor station
0 = disabled
1 = enabled
Relay
number
XX
0
20
1
23
2
26
3
29
4
32
5
35
6
38
7
41
8
44
Outdoor Outdoor Outdoor
station station station
0
1
2
*
200
*
XX
2
0
1
1
#
1
Example: to assign relay 0 and enable the staircase light button of outdoor station 0,
dial:
2
6.5
0
0
2
0
2
0
1
0
0
#
PROGRAMMING THE CALL REPEATER FUNCTION FOR EXTRA BELL
This programming can associate a relay to an extension. This relay activates when the associated
telephone receives a call (from outside telephone line, door entry unit and extension).
Identification number of the
relay to be associated
*
200
Identification number
of the extension called
XX
2
*
Z
#
where XX and Z have the following meaning:
XX
04
22
25
28
31
34
37
40
43
relay number
0 extension relay
relay 1
relay 2
relay 3
relay 4
relay 5
relay 6
relay 7
relay 8
Z
0
1
2
3
4
5
6
7
8
telephone number
416
401
402
403
404
405
406
407
408
Example: to associate relay 4 with extension 6 to operate the extra bell dial:
2
0
0
3
1
2
6
#
Terraneo
6
6.6
31
ADVANCED PROGRAMMING
PROGRAMMING REMOTELY OPERATED RELAYS AS MONOSTABLE
ACTUATORS ONLY FROM EXTENSIONS
This programming can define the monostable operation and establish the timing of the relay inside the exchange
and the relays on the extra expansion modules item 335916.
The programming on internal relay 0 excludes the “Switch staircase light on” door entry service and activates
the possibility of controlling the internal relay in monostable mode with a command from the keypad.
To reset the “Switch staircase light on” function (with
20004
Monostable actuator function
for just local command
Relay identification number
*
200
or R8) on relay 0, dial the sequence:
30 #
*
04
04 = internal relay 0
22 = relay 1
25 = relay 2
28 = relay 3
31 = relay 4
34 = relay 5
37 = relay 6
40 = relay 7
43 = relay 8
Timing
0
0
#
0 = 2 seconds
1 = 10 seconds
3 = 30 seconds
4 = 1 minute
5 = 3 minutes
6 = 10 minutes
7 = 30 minutes
8 = 60 minutes
Example: to program relay 1 as monostable actuator with 30-second timing dial:
2
6.7
0
0
2
2
0
3
#
PROGRAMMING REMOTELY OPERATED RELAYS AS BISTABLE
ACTUATORS ONLY FROM EXTENSIONS
This programming can define the bistable operation of the relay inside the exchange or, if installed, one
of the relays on the extra expansion modules item 335916.
The programming on relay 0 excludes the “Switch staircase light on” door entry service and activates the
possibility of controlling the relay in bistable mode with a command from the keypad.
Relay
identification number
*
*
04
200
04 = internal relay 0
22 = relay 1
25 = relay 2
28 = relay 3
31 = relay 4
34 = relay 5
37 = relay 6
40 = relay 7
43 = relay 8
#
02
Example: to program relay 4 as bistable actuator dial:
2
0
0
3
1
Note: to check relay operation see section 5.1 of the user manual.
0
2
#
PABX 18D
6
32
ADVANCED PROGRAMMING
6.8 PROGRAMMING REMOTELY OPERATED RELAYS AS MONOSTABLE
ACTUATORS FROM EXTENSIONS AND TELEPHONE LINE
This programming can define the monostable operation and establish the timing even from outside telephone
line of the relay inside the exchange and the relays on the extra expansion modules item 335916.
The programming on internal relay 0 excludes the “Switch staircase light on” door entry service and activates
the possibility of controlling the internal relay in monostable mode with a command from the keypad.
To reset the “Switch staircase light on” function (wit
20004
Monostable actuator function
Internal relay identification
number
*
200
or R8) on relay 0, dial the sequence:
30 #
*
04
04 = internal relay 0
22 = relay 1
25 = relay 2
28 = relay 3
31 = relay 4
34 = relay 5
37 = relay 6
40 = relay 7
43 = relay 8
Timing
1
0
#
0 = 2 seconds
1 = 10 seconds
3 = 30 seconds
4 = 1 minute
5 = 3 minutes
6 = 10 minutes
7 = 30 minutes
8 = 60 minutes
Example: to program relay 1 as monostable actuator with 30-second timing dial:
2
6.9
0
0
2
2
1
3
#
PROGRAMMING REMOTELY OPERATED RELAYS AS BISTABLE
ACTUATORS FROM EXTENSIONS AND TELEPHONE LINE
This programming can also define the bistable operation from the outside of the internal staircase light
relay or, if installed, one of the relays on the extra expansion modules item 335916.
The programming on relay 0 excludes the “Switch staircase light on” door entry service and activates the
possibility of controlling the internal relay in bistable mode with a command from the keypad.
Internal relay identification
number
*
*
04
200
04 = internal relay 0
22 = relay 1
25 = relay 2
28 = relay 3
31 = relay 4
34 = relay 5
37 = relay 6
40 = relay 7
43 = relay 8
#
12
Example: to program relay 4 as bistable actuator dial:
2
0
0
3
1
Note: to check relay operation see section 5.1 of the user manual.
1
2
#
Terraneo
6
33
ADVANCED PROGRAMMING
6.10 LENGTH OF THE CALL SIGNAL FROM THE OUTDOOR STATION
To reduce the length of the call signal from 30 seconds to 6 seconds.
1. Lift the receiver
2. Perform the programming access procedure (sect. 3.3).
3. Dial the sequence:
20003
0#
4. After receiving the confirmation tone, hang up.
To reset 30 seconds dial the sequence:
20003
1 #.
6.11 PROGRAMMING THE OUTSIDE MUSIC SOURCE
If an outside music source has been connected program as follows
1. Lift the receiver
2. Perform the programming access procedure (sect. 3.3).
3. Dial the sequence:
42002
2#
4. After receiving the confirmation tone, hang up.
To return to the basic music source
1. Lift the receiver
2. Perform the programming access procedure (sect. 3.3).
3. Dial the sequence:
42002
1#
4. After receiving the confirmation tone, hang up.
6.12 PROGRAMMING THE R (OR FLASH KEY) RECOGNITION TIMES
1.
Lift the receiver
2.
Perform the programming access procedure (sect. 3.3).
3.
Dial the sequence:
10008
0080 #
4. After receiving the confirmation tone dial the sequence:
10001
0065 #
10008
0025 #.
5. After receiving the confirmation tone, hang up.
To return to the basic conditions
1. Lift the receiver
2. Perform the programming access procedure (sect. 3.3).
3.
Dial the sequence:
10001
0015 #
4. After receiving the confirmation tone dial the sequence:
5. After receiving the confirmation tone, hang up.
Warning: Be very careful to respect the command entry sequence.
PABX 18D
7
34
HOUSE-AUTOMATION SCENARIO PERSONALISATION
Just one operation can activate one of the five programmings for:
incoming and outgoing calls (subdivision into bands for each telephone)
remote activation
recognition of the FAX and MODEM tone
door entry services
the Dosa service
These programmings are defined house-automation scenarios.
Each house-automation scenario can be activated by means of one of the following commands 311, 312,
313, 314 or 315.
The exchange is supplied with house-automation scenario 1 (311) active and house-automation scenario
2 (312) programmed for the night service (all incoming calls switched to extensions 401 and 402); the
other house-automation scenarios are the same as the first.
The installer can personalise the house-automation scenarios using the commands described below.
Make a note of the personalisations made in the “summary tables”.
7.1
ENABLING TELEPHONES FOR INCOMING AND OUTGOING CALLS
This personalisation can be performed using the following command, after performing the programming
access procedure (sect. 3.3).
As a base all the telephones connected to the exchange are enabled for incoming and outgoing calls.
House
automation
scenario
from 1 to 5
*
5
Telephone
Calls
number
2 outgoing
from 01 to 08 3 incoming
1
*
3
01
Line 1
0 disab.
1 enable
0
0
0
0
#
Example 1 – Modification of house-automation scenario 2 (night service).
To switch all the incoming telephone calls to telephone 401, modifying the programming of houseautomation scenario 2, (can be activated with command 312), which provides as basis for switching to
telephones 401 and 402, dial:
*
5
2
*
0
2
3
0
0
0
0
#
Example 2 – Modification of house-automation scenario 3.
To disable telephone 408 in house-automation scenario 3 (313) for outgoing calls (the basic programming
for scenario 3 has enabling for outgoing calls), dial:
5
3
0
8
2
0
0
0
0
#
Terraneo
7
35
HOUSE-AUTOMATION SCENARIO PERSONALISATION
7.2
PROGRAMMING REMOTE ACTIVATION AND RECOGNITION
OF FAX/MODEM
These services can be activated on each telephone line. To use the service perform both the programming
and the activation. The programming and activation commands must be sent to the exchange after
performing the programming access procedure (sect. 3.3).
PROGRAMMING
The programming occurs with the following command:
Remote
activation
0 disabled
1 enabled
Link with
scenario
311÷315
from 1 to 5
*
5
1÷5
3
1
*
1
Recognition
of FAX
and MODEM
0 disabled
1 enabled
0o1
0o1
0
0
0
0
#
0
#
ACTIVATION
After performing the programming the services must be activated with the following command:
Line 1
Link with
scenario
311÷315
from 1 to 5
*
3
5
0 disabled
1 enabled
3
0
0
*
0
0
0
0
0
Warning: The second command modifies the activations of the services on all the local lines; the
enabling of the services already programmed on other local lines must thus be reconfirmed.
Example:
To program the enabling for remote activation in house-automation scenario 3, associated with command
313, dial:
5
3
3
1
1
1
0
0
0
0
0
#
1
0
0
0
0
0
#
To make the programming performed active dial:
5
3
3
0
0
PABX 18D
7
7.3
36
HOUSE-AUTOMATION SCENARIO PERSONALISATION
PROGRAMMING WAIT RINGS
For remote activation the number of wait rings before answering can be set, to allow any answering
machines to work if an answering machine has been programmed; the exchange can still supply the
remote activation service.
Link with
scenario 311 – 315
from 1 to 5
*
5
1÷5
Telephone
line
3
N° of rings
1
2
*
1÷9
#
0
To complete the programming of the remote activation service at least one relay must be programmed for
remote activation.
7.4
MANAGEMENT OF FAX AND MODEM
The exchange can automatically recognise the FAX or MODEM tones from the local line and send the
call to the extensions programmed as FAX or MODEM. For the programming proceed as indicated in
points A, B and C.
The commands which follow can be sent to the exchange after performing the programming access
procedure (sect. 3.3).
A - Enabling for recognition of a FAX or MODEM tone
(for house-automation scenario 1)
Lift the receiver
Perform the programming access procedure
5
Dial:
1
3
1
0
0
1
0
0
0
#
Wait for the confirmation tone
Dial:
5
1
3
0
0
After receiving the confirmation tone, hang up.
1
0
0
0
0
0
#
Terraneo
7
37
HOUSE-AUTOMATION SCENARIO PERSONALISATION
B - Programming FAX or MODEM
To program the extension number where there will be a FAX or MODEM proceed as follows:
Modem on number 401
Lift the receiver
Perform the programming access procedure
Dial:
3
0
1
0
0
0
0
1
0
0
0
#
0
1
0
0
0
0
#
FAX on number 402
Lift the receiver
Perform the programming access procedure
Dial:
3
0
2
0
0
Note: Other extensions can have fax or modem. See the “Advanced programming” chapter
“Characterisation of an extension” section.
C - Disabling FAX or MODEM for door entry calls
(for house-automation scenario 1)
Lift the receiver
Perform the programming access procedure
Dial:
5
1
0
1
0
3
#
Wait for the confirmation tone
Dial:
5
1
0
2
0
3
#
PABX 18D
7
7.5
38
HOUSE-AUTOMATION SCENARIO PERSONALISATION
TRANSFERRING THE DOOR ENTRY CALL TO OUTSIDE TELEPHONE LINE
(DOSA SERVICE)
When the service is active, when there is a door entry call, the exchange rings the extensions enabled
and automatically dials a telephone number, landline or mobile, which the user has previously saved in
the short number phone book, transferring the call to the outside.
The telephone number must be saved in memory location:
- 50 of the short number phone book (see user manual sect. 6.11).
On answering the user will hear a confirmation tone which tells him that the call is from the exchange.
Then, to start the conversation and exclude the extensions, he must type a number between 0 and 9.
After 45 seconds of conversation the exchange sends a sound to warn the user that the conversation is
about to finish. If the user types a number between 0 and 9 the conversation can continue, if not, it will
end after 50 seconds.
The conversation time can be longer in the following cases:
Systems with dedicated speaker unit item 335902 connected directly to the telephone exchange;
Systems with video distributor item 335918, dedicated outdoor stations item 335902 and 335910
and extra cameras;
Systems with video distributor connected to the analog riser with just one outdoor station.
It is not possible in the following cases:
Analog or digital systems with door entry interface item 335910;
Systems with video distributor item 335918 connected to the digital riser;
Systems with video distributor item 335918 connected to the analog riser with camera switcher item
391467
To finish the conversation early press
*
or
#.
Terraneo
7
39
HOUSE-AUTOMATION SCENARIO PERSONALISATION
Programming the Dosa service
Typing the following command programs the Dosa service, after performing the programming access
procedure:
*
House
automation
scenario
from 1 to 5
Outdoor station on which the
Dosa service will be activated
1
00
*
83
1
2
3
4
5
=
=
=
=
=
scenario
scenario
scenario
scenario
scenario
1
2
3
4
5
#
00 = deactivated on door entry call 1 and 2
01 = activated on door entry call 2
10 = activated on door entry call 1
11 = activated on door entry call 1 and 2
Programming example
Lift the receiver
Press the
Type:
#
R
key, you will hear the start-dialling tone
#
Dial the password (e.g. base
1
2
3
4
)
If the password is correct you will hear a start-dialling tone
To activate the Dosa service in house-automation scenario 5 on door entry call 1, dial:
8
3
5
1
0
#
After receiving the confirmation tone (3 quick tones) hang up.
Once programmed the service will be activated with telephone command 315 for house-automation
scenario 5.
Note: in the basic exchange configuration, this service is deactivated on all the house-automation
scenarios.
PABX 18D
8
40
CALL LOCK MANAGEMENT
This programming can define for each telephone which telephone prefixes cannot be called.
The locked telephones must be programmed individually.
In basic programming conditions all prefixes are unlocked.
There are two types of lock:
1. Lock prefix 00
2. Lock programmed prefixes
The locks are valid for all the programmed telephone carriers as described below.
The type of lock activated can be defined for each telephone.
Warning: lock 1 excludes lock 2
To be able to make a telephone call to a number which begins with a locked prefix the prefixes must be
temporarily unlocked (see “Temporary unlock” section in the “User Instruction” manual).
The emergency numbers (112 carabinieri, 113 emergency, etc.) are not locked and can thus be called
even if the active prefixes are locked.
8.1
LOCK PREFIX 00
The procedure to lock prefix 00 is the following:
1. Lift the receiver.
2. Press the
key
3. Dial the sequence 961 XXXX (where XXXX corresponds to the programming password) 01 (Extension
number from 01 to 08) R to lock prefix 00 on telephone 1.
The procedure to unlock prefix 00 on telephone 1 is the following:
1. Dial the sequence 960 XXXX (where XXXX corresponds to the programming password) 01 (Extension
number from 01 to 08) R.
2.
After receiving the confirmation tone, hang up.
To individually lock the telephone carriers for international calls do not use this lock (prefix 00) but the
programmed carriers lock; see section below and examples.
8.2
LOCK PROGRAMMED PREFIXES
The “lock programmed prefixes” operation locks a series of prefixes which has previously been defined
and entered in the exchange.
The lock programmed prefixes procedure is the following:
1. Lift the receiver.
2. Press the
key
3. Dial the sequence 951 XXXX (where XXXX corresponds to the programming password) 01 (Extension
number from 01 to 08) R to lock programmed prefixes 00 on telephone 1.
The procedure to unlock the programmed prefixes on telephone 1 is the following:
1. Dial the sequence 950 XXXX (where XXXX corresponds to the programming password) 01 (Extension
number from 01 to 08) R to unlock the programmed prefixes on telephone 1.
2. After receiving the confirmation tone, hang up.
Terraneo
8
8.3
41
CALL LOCK MANAGEMENT
ENTERING PREFIXES TO BE LOCKED
1. Fill in the table of the prefixes to be locked.
nn
01
02
03
04
05
06
07
08
Prefix to be locked max. 4 numbers
2. Lift the receiver.
3. Press the
key
4. Dial the sequence 370 XXXX (where XXXX are the four numbers of the programming password).
5. Wait for the dial tone.
6. Dial the sequence nn (from 01 to 08) YYYY (YYYY prefix to lock maximum 4 numbers) R.
7. Wait for the confirmation tone and then enter other prefixes (maximum 8) repeating operation 5.
8. Hang up.
If a mistake is made when entering the prefix hang up and repeat all the operations starting from 2.
To cancel a prefix to be locked, proceed as above and in point 5 dial the sequence nn (from 01 to 08) R.
Warning: if you want the “programmed prefix lock” and the “international call lock” simultaneously,
enter prefix 00 in the “prefixes to lock” table and do not use the “lock prefix 00” function.
PABX 18D
8
42
CALL LOCK MANAGEMENT
8.4 ENTERING PREFIXES TO BE UNLOCKED FOR TELECOM
If, after performing the lock with the operation described above, you want to unlock one or more prefixes
(e.g.: having locked 0 you want to be able to make local and not long-distance calls) proceed as follows:
1. Fill in the table of the prefixes to be unlocked for Telecom carrier:
nn
01
02
03
04
05
06
07
08
Prefix to be unlocked max. 4 numbers
2. Lift the receiver.
3. Press the
key
4. Dial the sequence 371 XXXX (where XXXX are the four numbers of the programming password).
5. Wait for the dial tone.
6. Dial the sequence nn (from 01 to 08) YYYY (YYYY prefix to unlock) R.
7. Wait for the confirmation tone and then enter other prefixes (maximum 8) repeating operation 5.
8. Hang up.
If a mistake is made when entering the prefix hang up and repeat all the operations starting from 2.
To cancel a prefix to be unlocked, proceed as above and in point 5 dial the sequence nn (from 01 to 08) R.
Note: If prefix “1” is locked you can still make emergency calls to the police, fire brigade, etc.. (112, 113,
115, 116, 117, 118 and 19696)
Terraneo
8
8.5
43
CALL LOCK MANAGEMENT
ENTERING PREFIXES OF OTHER CARRIERS
If you want the exchange to recognise other carriers (max 5) proceed as follows:
1. Fill in the table of enabled carriers.
nn
01
02
03
04
05
Carrier
Prefix YYYYYY
2. Lift the receiver.
3. Press the
key
4. Dial the sequence 380 XXXX (where XXXX are the four numbers of the programming password).
5. Wait for the dial tone.
6. Dial the sequence nn (from 01 to 05) YYYYYY (carrier prefix from 4 to 6 numbers) R.
7. Wait for the confirmation tone and then enter other carrier prefixes (maximum 5) repeating
operation 5.
8. Hang up.
If a mistake is made when entering the carrier prefix hang up and repeat all the operations starting from 2.
To cancel a carrier prefix, proceed as above and in point 5 dial the sequence nn (from 01 to 05) R.
PABX 18D
8
8.6
44
CALL LOCK MANAGEMENT
PREFIXES TO BE UNLOCKED FOR OTHER CARRIERS
Each carrier has an unlock table which defines which telephone prefixes (maximum 3) should be unlocked
only for that carrier.
Carrier 01 table
Prefix to be unlocked max. 4 numbers
nn
01
02
03
Carrier 02 table
01
02
03
Carrier 03 table
01
02
03
Carrier 04 table
01
02
03
Carrier 05 table
01
02
03
1. Fill in the table of the carriers with prefixes to be unlocked:
2. Soulever le combiné
3. Press the
key
4. Dial the sequence 381 XXXX (where XXXX are the four numbers of the programming password) to
unlock the prefixes of the table for carrier 01.
5. Wait for the dial tone.
6. Dial the sequence nn (from 01 to 03) YYYY (prefix to unlock) R.
7. Wait for the confirmation tone and then enter other prefixes to be unlocked (maximum 3) repeating
operation 5.
8. Hang up.
Proceed in the same way to unlock the prefixes for other carriers dialling the sequences:
382 XXXX for carrier 02
383 XXXX for carrier 03
384 XXXX for carrier 04
385 XXXX for carrier 05
If for one or more carriers you want to unlock the prefixes already defined in the Telecom carrier table, in
point 4 dial the sequence 01 # R; any other prefixes are ignored.
To cancel a prefix to be unlocked associated with a carrier, proceed as above and in point 5 dial the
sequence nn (from 01 to 03) R.
Terraneo
8
8.7
45
CALL LOCK MANAGEMENT
EXAMPLE OF ACTIVATION OF LOCKS ON OUTGOING DIALLING
The following operations should be performed to activate locks on outgoing dialling:
1. Define which telephone prefixes should be locked and make a note of them in the table
2. Define which are the Telecom telephone prefixes to be unlocked and make a note of them in the
table. As an example, if the 0 is locked, but you want to make calls in your local area, unlock its
telephone prefix (02 for Milan, 06 for Rome, etc.)
3. Define the other carriers (as well as Telecom) and make a note of them in the table
4. Define the telephone prefixes to be unlocked for each carrier and make a note of them in the table
EXAMPLE 1
Lock long-distance calls with just one carrier (Telecom)
A. Fill in the table of prefixes to be locked (0 for all Telecom local and long-distance calls)
nn
Prefix to be locked max. 4 numbers
01
0
A.1 Lift the receiver
A.2 Press the
key
A.3 Dial the sequence:
Password (ex. 1234)
3
7
0
1
2
3
From the table of prefixes to be locked
prefix
nn
4
0
1
0
R
A.4 After receiving the confirmation tone, hang up
B. Fill in the table of prefixes to be unlocked (unlock the local area prefix to make just local calls. As an
example for Milan 02, for Rome 06 etc.).
nn
Prefix to be unlocked max 4 numbers
01
02 (for Milan)
B.1 Lift the receiver
B.2 Press the
key
B.3 Dial the sequence:
Password (e.g. 1234) From the table of prefixes to be unlocked
prefix
nn
3
7
1
1
2
3
4
B.4 After receiving the confirmation tone, hang up
0
1
0
2
R
PABX 18D
8
46
CALL LOCK MANAGEMENT
EXAMPLE 2
Lock long-distance calls via Telecom and enable other carriers for long-distance and international
calls
In the example long-distance calls via Telecom are locked, the first carrier (01) is enabled for long-distance
calls and the second carrier (02) for international calls.
A. Fill in the table of prefixes to be locked (0 and 00 for all local and long-distance calls)
nn
Prefix to be locked
01
02
0
00
A.1 Lift the receiver
A.2 Press the
key
A.3 Dial the sequence:
Password (ex. 1234)
3
7
0
1
2
3
From the table of prefixes to be locked
prefix
nn
4
0
1
0
R
A.4 After receiving the confirmation tone, hang up
A.5 Lift the receiver
A.6 Press the
A.7
key
Dial the sequence:
Password (ex. 1234)
3
7
0
1
2
3
From the table of the prefixes to be locked
nn
prefix
4
A.8 After receiving the confirmation tone, hang up
Go to point B.
0
2
0
0
R
Terraneo
8
47
CALL LOCK MANAGEMENT
B. Fill in the table of prefixes to be unlocked (unlock the local area prefix to make just local calls. As an
example for Milan 02, for Rome 06 etc.).
nn
Prefix to be unlocked
01
02 (for Milan)
B.1 Lift the receiver
B.2 Press the
key
B.3 Dial the sequence:
Password (e.g. 1234) From the table of prefixes to be unlocked
prefix
nn
3
7
1
1
2
3
4
0
1
0
2
R
B.4 After receiving the confirmation tone, hang up
C. Fill in the table of enabled carriers (define the carriers for long-distance calls)
nn
Carrier
01
02
........
........
Prefix
YYYY
ZZZZ
C.1 Lift the receiver
C.2 Press the
key
C.3 Dial the sequence:
Password (ex. 1234)
3
8
0
1
2
3
From the table of enabled carriers
nn
prefix
4
0
1
Y
Y
Y
Y
R
C.4 After receiving the confirmation tone, hang up
C.5 Lift the receiver
C.6 Press the
key
C.7 Dial the sequence:
Password (ex. 1234)
3
8
0
1
2
3
From the table of enabled carriers
nn
prefix
4
C.8 After receiving the confirmation tone, hang up
Go to point D
0
2
Z
Z
Z
Z
R
PABX 18D
8
48
CALL LOCK MANAGEMENT
D. Fill in the table of prefixes to be unlocked for each carrier (in the example the first carrier 01 is enabled
for long-distance calls and the second carrier 02 just for international calls).
Carrier 01 table
Prefix to be unlocked max. 4 numbers
0
nn
01
02
03
Carrier 02 table
Prefix to be unlocked max. 4 numbers
00
nn
01
02
D.1 Lift the receiver
D.2 Press the
key
D.3 Dial the sequence:
Password (ex. 1234) From the table of the prefixes to be unlocked for carrier 1
nn
prefix
3
8
1
1
2
3
4
0
1
0
R
D.4 After receiving the confirmation tone, hang up
Note: In this way carrier 01 is enabled for all calls with numbers which begin with 0, but international calls
(numbers which begin with 00) are locked (because they are in the table of prefixes to be locked).
D.5 Lift the receiver
D.6 Press the
key
D.7 Dial the sequence:
Password (ex. 1234)
3
8
2
1
2
3
From the table of prefixes to be unlocked for carrier 2
nn
prefix
4
0
1
0
0
R
D.8 After receiving the confirmation tone, hang up
Note: In this way carrier 02 is enabled for all calls with numbers which begin with 00 (international), but
the other numbers which begin with 0 are locked (because they are in the table of prefixes to be locked).
Terraneo
8
49
CALL LOCK MANAGEMENT
EXAMPLE 3
Lock long-distance calls via Telecom and enable other carriers for long-distance, international
and satellite calls
In the example long-distance calls via Telecom are locked, the first carrier (01) is enabled for long-distance
and international calls and the second carrier (02) for satellite calls.
A. Fill in the table of prefixes to be locked (0 for all local and long-distance calls, 0088 for all satellite
calls).
nn
Prefix to be locked max 4 numbers
01
02
0
0088
A.1 Lift the receiver
A.2 Press the
key
A.3 Dial the sequence:
Password (ex. 1234)
3
7
0
1
2
3
From the table of prefixes to be locked
prefix
nn
4
0
1
0
R
A.4 After receiving the confirmation tone, hang up
A.5 Lift the receiver
A.6 Press the
key
A.7 Dial the sequence:
Password (ex. 1234) From the table of prefixes to be unlocked for carrier 2
nn
prefix
3
7
0
1
2
3
4
A.8 After receiving the confirmation tone, hang up
Go to point B.
0
1
0
0
8
8
R
PABX 18D
8
50
CALL LOCK MANAGEMENT
B. Fill in the table of prefixes to be locked (unlock the local area prefix to make just local calls. As an
example for Milan 02, for Rome 06 etc.).
B.1
nn
Prefix to be unlocked max 4 numbers
01
02 (for Milan)
Lift the receiver
B.2 Press the
key
B.3 Dial the sequence:
Password (e.g. 1234) From the table of prefixes to be unlocked
prefix
nn
3
7
1
1
2
3
4
B.4 After receiving the confirmation tone, hang up
Go to point C
0
1
0
2
R
Terraneo
8
51
CALL LOCK MANAGEMENT
C. Remplir le tableau des gérants autorisés (il faut définir quels sont les gérants pour les communications
interurbaines, internationales et via satellite).
nn
Gérant
Indicatif
01
02
........
........
YYYY
ZZZZ
C.1 Lift the receiver
C.2 Press the
key
C.3 Dial the sequence:
Password (ex. 1234)
3
8
0
1
2
3
From the table of enabled carriers
nn
prefix
4
0
1
Y
Y
Y
Y
R
C.4 After receiving the confirmation tone, hang up
C.5 Lift the receiver
C.6 Press the
key
C.7 Dial the sequence:
Password (ex. 1234)
3
8
0
1
2
3
From the table of enabled carriers
nn
prefix
4
C.8 After receiving the confirmation tone, hang up
Go to point D
0
2
Z
Z
Z
Z
R
PABX 18D
8
52
CALL LOCK MANAGEMENT
D. Fill in the table of prefixes to be unlocked for each carrier (in the example the first carrier is enabled
for all the long-distance and international calls and the second carrier just for satellite calls).
carrier 01 table
Prefix to be unlocked max 4 numbers
0
nn
01
02
03
carrier 02 table
Prefix to be unlocked max 4 numbers
0088
nn
01
02
03
D.1 Lift the receiver
D.2 Press the
key
D.3 Dial the sequence:
Password (ex. 1234) From the table of the prefixes to be unlocked for carrier 1
nn
prefix
3
8
1
1
2
3
4
0
1
0
R
D.4 After receiving the confirmation tone, hang up
Note: In this way carrier 01 is enabled for all calls with numbers which begin with 0, including international
calls (numbers which begin with 00) unlike example 2 (because 00 is not in the table of prefixes to be
locked). For this carrier satellite calls remain locked (because 0088 is in the table of prefixes to be locked).
D.5 Lift the receiver
D.6 Press the
key
D.7 Dial the sequence:
Password (ex. 1234) From the table of prefixes to be unlocked for carrier 2
nn
prefix
3
7
0
1
2
3
4
0
1
D.8 After receiving the confirmation tone, hang up
Note: In this way carrier 02 is enabled only for satellite calls.
0
0
8
8
R
Terraneo
9
9.1
53
INSTALLATION
CABLES AND CONNECTIONS
Use cables which comply with CEI Standards.
Cables for the connection of telephones and speaker units item 335902; use twisted rigid one-pair
telephone cables, with conductor 0.28 mm2.
Connection cable for the Outdoor door entry or video door entry station: depending on the type of
door entry or video door entry system to be connected.
Maximum distance between exchange and telephone 200 metres.
Maximum distance between exchange and outdoor station 200 metres (with speaker unit item
335902)..
9.2
INSTALLING PABX EXCHANGE
After arranging the cables connect the devices as indicated in the diagrams.
Install the PABX inside the cabinet with DIN rail
Install the cabinet closing cover
spa
828
PAB
230V
spa
X 28D
PAB
230V
cod.
335828
A
5828
0,15
3315%
50 Hz
Patent
Pen
ding
X 28D
335
cod.
A
5828
0,15
3315%
50 Hz
Patent
ding
Pen
PABX 18D
9
9.3
54
INSTALLATION
COMPOSITION OF THE TELEPHONES + VIDEO SECTION (VIDEO DOOR
ENTRY TELEPHONES)
The telephone + video section (video door entry telephone) can be made up depending on the type of
telephone (compact or standard) and its colour (white or grey).
For a correct combination consult the tables below.
COLOUR
COMPACT TELEPHONES
Art. 335022
VIDEO SECTION
Art. 335102
1..............
2..............
3..............
4..............
5..............
6..............
WHITE
7..............
8..............
9..............
M1
4
5
6
R
7
8
9
RP
0
Art. 335023
Art. 335103
1..............
2..............
3..............
4..............
5..............
6..............
GREY
COLOUR
7..............
8..............
9..............
M1
4
5
6
R
7
8
9
RP
0
STANDARD TELEPHONES
Art. 335032
WHITE
1..............
2..............
3..............
VIDEO SECTION
Art. 335102
4..............
7..............
5..............
8..............
6..............
9..............
M1
R
RP
1
2
3
4
5
6
7
8
9
0
Art. 335033
GREY
1..............
2..............
3..............
Art. 335103
4..............
7..............
5..............
8..............
6..............
9..............
M1
R
RP
1
2
3
4
5
6
7
8
9
0
Terraneo
9
55
INSTALLATION
9.4 INSTALLING THE TELEPHONE + WALL-MOUNTED VIDEO SECTION
To install the telephones + wall-mounted video section (video door entry telephones) connect the braided
cable (1) which comes with the Pivot telephone following the correspondence of the conductors as indicated
in the table below.
BRAIDED CABLE
CABLE N.
1
2
3
4
5
6
7
8
COLOUR
YELLOW
GREEN
BLUE
WHITE
BROWN
RED
BLACK
GREY
FUNCTION
GND
+V
TEL. LINE
TEL LINE
BELL
ON
VID VID +
1
11
44
77
22
55
88
33
66
99
P
R
RP
00
P
R
RP
9.5 INSTALLING THE TELEPHONE + TABLE-MOUNTED VIDEO SECTION
To install the telephones + table-mounted video section (video door entry telephones) connect the
conductors to the terminals of the 8-way socket as indicated in the table below.
Art. 336813
PABX 18D
9
9.6
56
INSTALLATION
CONNECTION DIAGRAMS
Audio system with one door entry call with dedicated speaker unit
Up to 3 outdoor stations can be connected without mixer. The system automatically switches to the
outdoor station from which the call was made.
If, while a door entry conversation is taking place, a call is made from one of the two temporarily excluded
speaker units, you will hear a telephone busy tone. One of the three outdoor stations can be fitted with a
nameplate for address or other information.
The speaker units of outdoor stations 1 and 2 must be configured.
At rest the open door lock command acts on the main outdoor station.
~
230 V
Telephone line
Warning: connect
the exchange and
telephone
protection (PLT1)
earth terminal to
the earth of the
electric system
PRI
C
NO
a b a b a b a b a b a b a b a b
1
a b
IN
2
3
4
5
6
7
8
Exchange
PLT1
335818
OUT
a b
U1
a b
3 4 MP T R
OPTIONALS
N S
3 4
Outdoor
Station
N2
2
N S
3 4
1
N S
3 4
Main Outdoor
Station 0
5 6 7 8
5 6 7 8
5 6 7 8
1 2 3 4
1 2 3 4
1 2 3 4
PL PL C S+ S -
Outdoor
Station
N1
PL PL C S+ S -
Dedicated
speaker unit
item 335902
PL PL C S+ S -
Pushbutton
to open
door lock
18V
4A impulsive
Terraneo
9
57
INSTALLATION
Maximum distance between
type of cable
furthest away outdoor station —> PABX
200 m
telephone pair 0.28 mm2
Telephone 1
1.............. 4.............. 7..............
a
b
2.............. 5.............. 8..............
3.............. 6.............. 9..............
(401)
Telephone 2
1..............
2..............
3..............
4..............
5..............
6..............
7..............
8..............
a
b
9..............
1
2
3
4
5
6
R
7
8
9
RP
M1
0
(402)
Telephone 3
1..............
2..............
3..............
4..............
5..............
6..............
7..............
8..............
9..............
a
b
1
2
3
4
5
6
R
7
8
9
RP
M1
0
(403)
PABX———> telephone
200 m
telephone pair 0.28 mm2
PABX 18D
9
58
INSTALLATION
System with two door entry calls with dedicated speaker unit
~
230 V
Telephone line
Warning: connect
the exchange and
telephone
protection (PLT1)
earth terminal to
the earth of the
electric system
PRI
C
NO
a b a b a b a b a b a b a b a b
1
a b
IN
2
3
4
5
6
7
8
Exchange
PLT1
335818
OUT
a b
U1
a b
3 4 MP T R
OPTIONALS
N S
3 4
Outdoor
Station
N2
2
N S
3 4
1
3 4
Main Outdoor
Station 0
5 6 7 8
5 6 7 8
5 6 7 8
1 2 3 4
1 2 3 4
1 2 3 4
PL PL C S+ S -
Outdoor
Station
N1
Call 2
Call 1
N S
PL PL C S+ S -
Dedicated
speaker unit
item 335902
PL PL C S+ S -
Pushbutton
to open
door lock
18V
4A impulsive
Terraneo
9
59
INSTALLATION
Maximum distance between
type of cable
furthest away outdoor station —> PABX
200 m
telephone pair 0.28 mm2
Telephone 1
PABX———> telephone
200 m
telephone pair 0.28 mm2
Telephone 2
1.............. 4.............. 7..............
2.............. 5.............. 8..............
a
b
3.............. 6.............. 9..............
1.............. 4.............. 7..............
2.............. 5.............. 8..............
a
b
3.............. 6.............. 9..............
(401)
Telephone 3
(402)
Telephone 4
1..............
1..............
2..............
2..............
3..............
3..............
4..............
4..............
5..............
5..............
6..............
6..............
7..............
7..............
8..............
a
b
8..............
9..............
1
2
3
a
b
M1
4
5
6
R
7
8
9
RP
0
9..............
1
2
3
M1
4
5
6
R
7
8
9
RP
0
(403)
Telephone 5
(404)
Telephone 6
1..............
1..............
2..............
2..............
3..............
3..............
4..............
4..............
5..............
5..............
6..............
6..............
7..............
7..............
8..............
8..............
9..............
a
b
1
2
3
9..............
a
b
M1
4
5
6
R
7
8
9
RP
0
1
2
3
M1
4
5
6
R
7
8
9
RP
0
(405)
Telephone 7
(406)
Telephone 8
1..............
1..............
2..............
2..............
3..............
3..............
4..............
4..............
5..............
5..............
6..............
6..............
7..............
7..............
8..............
a
b
8..............
9..............
1
2
3
a
b
M1
4
5
6
R
7
8
9
RP
0
(407)
Door entry call 1
9..............
1
2
3
M1
4
5
6
R
7
8
9
RP
0
(408)
Door entry call 2
PABX 18D
9
60
INSTALLATION
Audio system with one door entry call connected to the riser of the 2-wire system (audio)
APARTMENT 3
BUS
APARTMENT 2
1..............
2..............
3..............
4..............
5..............
N
3
6..............
P
7..............
8..............
9..............
1
2
3
4
5
6
R
7
8
9
RP
0
M1
344032
230V a.c.
50-60 Hz
a
BUS
PRI
PRI
6
1
5
a b a2 b a3 b a4 b a b a b a
b
Telephone 1
a b a b a b a b a b a b a b a b
C
NO
C NO
1
2
3
4
5
6
7
Exchange
8
1..............
a
b
335818
2..............
3..............
M1
4..............
7..............
5..............
8..............
6..............
9..............
R
RP
1
2
3
4
5
6
7
8
9
0
Call to
the floor
U1
a b
U2
3 4 MP T R
a
U1
b
(401)
3 4
Telephone line
6
a b
IN
PLT1
Telephone 2
1..............
2..............
3..............
MAX 1m
4..............
OUT
a b
5..............
6..............
7..............
8..............
a
b
9..............
1
2
3
M1
4
5
6
R
7
8
9
RP
0
(402)
3
4 M P T R
346810
AUX
346810
spa
NN
NP
NN1
2
2 FILI
S C S
BUS
N
BUS
1
344202
344212
APARTMENT 1
2-wire audio system
riser
Warning: Arrange the configurators on interface item 346810 as indicated in the diagram.
Terraneo
9
61
INSTALLATION
Audio system with two door entry calls connected to the riser of the 2-wire system (audio)
APARTMENT 4
BUS
APARTMENT 2 and 3
1..............
2..............
3..............
4..............
5..............
N
4
6..............
P
7..............
8..............
9..............
1
2
3
4
5
6
R
7
8
9
RP
0
M1
344032
230V a.c.
50-60 Hz
a
BUS
PRI
6
1
5
a b a2 b a3 b a4 b a b a b a
b
Door entry call 1
a b a b a b a b a b a b a b a b
C
NO
C NO
PRI
1
2
3
4
5
6
7
Exchange
1..............
a
b
335818
Call to
the floor
8
2..............
3..............
M1
4..............
7..............
5..............
8..............
6..............
9..............
R
RP
1
2
3
4
5
6
8
9
7
0
U1
a b
3 4 MP T R
a
U2
U1
b
(401)
3 4
Telephone line
6
a b
IN
PLT1
1..............
2..............
3..............
MAX 1m
4..............
OUT
a b
5..............
6..............
7..............
8..............
a
b
9..............
1
2
3
M1
4
5
6
R
7
8
9
RP
0
(402)
Door entry call 2
3
1st door
entry call
NN
2
NP
4 M P T R
346810
AUX
346810
spa
NN1
3
2nd door
entry call
2 FILI
S C S
BUS
N
BUS
1
344202
344212
APARTMENT 1
2-wire audio system
riser
Warning: Arrange the configurators on interface item 346810 as indicated in the diagram.
PABX 18D
9
62
INSTALLATION
Audio system with one door entry call connected to the riser of the 2-wire system (video)
BUS
riser
APARTMENT 2
APARTMENT 3
230V a.c.
50-60 Hz
344102
a
N
PRI
PRI
P
3
a b a b a b a b a b a b a b a b
1
2
3
4
5
6
7
8
1..............
2..............
3..............
4..............
5..............
6..............
7..............
8..............
Exchange
video door entry
telephone
U1
a b
a
U2
b
9..............
a
b
335818
BUS
Call to
the floor
Telephone 1
6
5
4
a3 b a b a b a b a
1
a b a
b
C
NO
C NO
1
2
3
4
5
6
R
7
8
9
RP
3 4 MP T R
a
U1
b
M1
0
(401)
3 4
6
Telephone line
3
a b
IN
4 M P T R
346810
PLT1
AUX
OUT
a b
346810
NN
P
NN1
2
ON
OFF
Floor distribution
block
2 FILI
344102
S C S
BUS
N
2
ART. 346840
IN
OUT
PI
P2
P3
video door entry
telephone
P4
344102
BUS
N
P
1
2-wire video system
riser
P
video door entry
telephone
APARTMENT 1
Warning: Arrange the configurators on interface item 346810 as indicated in the diagram.
Terraneo
9
63
INSTALLATION
Audio system with two door entry calls connected to the riser of the 2-wire system (video)
BUS
APARTMENT 3 and 4
riser
APARTMENT 5
344102
1.............. 4.............. 7..............
N
2.............. 5.............. 8..............
a
b
P
3.............. 6.............. 9..............
5
230V a.c.
50-60 Hz
video door entry
telephone
(401)
BUS
a
PRI
PRI
6
a 1 b a2 b a3 b a4 b a 5 b a b a
b
Door entry call 1
a b a b a b a b a b a b a b a b
C NO
NO
C
1
2
3
4
5
6
7
8
Exchange
1..............
2..............
335818
Call to
the floor
U1
a b
a
U2
b
3..............
4..............
5..............
6..............
7..............
8..............
9..............
a
b
1
2
3
M1
4
5
6
R
7
8
9
RP
0
3 4 MP T R
a
U1
b
3 4
(402)
6
Telephone line
Door entry call 2
3
a b
IN
4 M P T R
346810
PLT1
2nd door
entry call
AUX
OUT
a b
346810
NN
3
P
NN1
4
1st door
entry call
2 FILI
344102
BUS
N
S C S
APARTMENT 2
P
2
video door entry
telephone
344102
BUS
N
APARTMENT 1
P
1
video door entry
telephone
BUS
2-wire audio system
riser
Warning: Arrange the configurators on interface item 346810 as indicated in the diagram.
PABX 18D
9
64
INSTALLATION
Audio system with one door entry call connected to the riser of the analog or digital systems
~
230 V
Telephone line
PRI
Warning: connect
the exchange and
telephone
protection (PLT1)
earth terminal to
the earth of the
electric system
a b
IN
C
NO
a b a b a b a b a b a b a b a b
1
2
3
4
5
6
7
8
Exchange
PLT1
335818
OUT
a b
U1
a b
3 4 MP T R
34
Interface
335910
1 2 3 4 5 6 2
Analog or digital system to the
floor distribution
5
Warning: Interface item 335910 must be set up as a function of the system to which it is connected
ON
ON
1 2 3 4
Analog system
1 2 3 4
Digital system
Note: as a base the interface is supplied to be connected to an analog system.
Terraneo
9
65
INSTALLATION
Telephone 1
1.............. 4.............. 7..............
a
b
Warning: interface item
335910 must be located
as close as possible to
the exchange (max.
distance 1 m)
2.............. 5.............. 8..............
3.............. 6.............. 9..............
(401)
Telephone 2
1..............
2..............
3..............
4..............
5..............
6..............
7..............
8..............
a
b
9..............
1
2
3
4
5
6
R
7
8
9
RP
M1
0
(402)
Telephone 3
1..............
2..............
3..............
4..............
5..............
6..............
7..............
8..............
a
b
9..............
1
2
3
4
5
6
R
7
8
9
RP
M1
0
(403)
PABX 18D
9
66
INSTALLATION
Audio system with two door entry calls connected to the riser of the analog or digital systems
~
230 V
Telephone line
PRI
Warning: connect
the exchange and
telephone
protection (PLT1)
earth terminal to
the earth of the
electric system
C
NO
a b
IN
a b a b a b a b a b a b a b a b
1
2
3
4
5
6
7
8
Exchange
PLT1
335818
OUT
a b
U1
a b
3 4 MP T R
3 4
3 4
Interface
335910
call 2
Interface
335910
call 1
Warning: interface item
335910 must be located
as close as possible to
the exchange (max.
distance 1 m)
1
Analog or digital system
to the floor distribution
Call 1
Call 2
3 4 5 6
1
3 4 5 6
5
5
Warning: Interface item 335910 must be set up as a function of the different types of system, by
means of dip-switches, as follows:
ON
ON
1 2 3 4
Door entry call 1
analog system
ON
ON
1 2 3 4
Door entry call 2
analog system
1 2 3 4
Door entry call 1
digital system
1 2 3 4
Door entry call 2
digital system
Terraneo
9
67
INSTALLATION
Telephone 1
Telephone 2
1.............. 4.............. 7..............
2.............. 5.............. 8..............
a
b
3.............. 6.............. 9..............
1.............. 4.............. 7..............
2.............. 5.............. 8..............
a
b
3.............. 6.............. 9..............
(401)
Telephone 3
(402)
Telephone 4
1..............
1..............
2..............
2..............
3..............
3..............
4..............
4..............
5..............
5..............
6..............
6..............
7..............
7..............
8..............
a
b
8..............
9..............
1
2
3
4
5
6
R
7
8
9
RP
9..............
a
b
M1
0
1
2
3
M1
4
5
6
R
7
8
9
RP
0
(403)
Telephone 5
(404)
Telephone 6
1..............
1..............
2..............
2..............
3..............
3..............
4..............
4..............
5..............
5..............
6..............
6..............
7..............
7..............
8..............
8..............
9..............
a
b
1
2
3
M1
4
5
6
R
7
8
9
RP
9..............
a
b
0
1
2
3
4
5
6
R
7
8
9
RP
M1
0
(405)
Telephone 7
(406)
Telephone 8
1..............
1..............
2..............
2..............
3..............
3..............
4..............
4..............
5..............
5..............
6..............
6..............
7..............
7..............
8..............
a
b
8..............
9..............
1
2
3
M1
4
5
6
R
7
8
9
RP
a
b
0
(407)
Door entry call 1
9..............
1
2
3
4
5
6
R
7
8
9
RP
M1
0
(408)
Door entry call 2
PABX 18D
9
68
INSTALLATION
Audio system with one door entry call connected to “4-wire + n” system
~
230 V
Telephone line
PRI
Warning: connect
the exchange and
telephone
protection (PLT1)
earth terminal to
the earth of the
electric system
a b
IN
C
NO
a b a b a b a b a b a b a b a b
1
2
3
4
5
6
7
8
Exchange
335818
PLT1
OUT
a b
U1
a b
3 4 MP T R
34
Warning: interface item
335910 must be located
as close as possible to
the exchange (max.
distance 1 m)
Interface
335910
1 2 3 4 5 6 2
Riser
4-wire + n system
(n)
(n)
603R
600
600WS
2
6
1
3
T
Warning: Interface item 335910 must be set up as a function of the system to which it is connected
ON
ON
1 2 3 4
Analog system
1 2 3 4
Digital system
Note: as a base the interface is supplied to be connected to an analog system.
Terraneo
9
69
INSTALLATION
Telephone 1
1.............. 4.............. 7..............
a
b
2.............. 5.............. 8..............
3.............. 6.............. 9..............
(401)
Telephone 2
1..............
2..............
3..............
4..............
5..............
6..............
7..............
8..............
a
b
9..............
1
2
3
4
5
6
R
7
8
9
RP
M1
0
(402)
Telephone 3
1..............
2..............
3..............
4..............
5..............
6..............
7..............
8..............
a
b
9..............
1
2
3
4
5
6
R
7
8
9
RP
M1
0
(403)
PABX 18D
9
70
INSTALLATION
One-call audio and video system, connected to the dedicated outdoor station, with two telephones
+ video section (video door entry units) switched on at the same time.
a
b
230V a.c.
50-60Hz
PRI
C
NO
a b a b a b a b a b a b a b a b
1
2
3
4
5
6
7
8
1.............. 4.............. 7..............
2.............. 5.............. 8..............
3.............. 6.............. 9..............
(403)
Exchange
335818
U1
a b
3 4 MP T R
6
Telephone line
a b
IN
PLT1
OUT
a b
Main Outdoor Station
Dedicated outdoor station 1
Camera
module item
332510
5 6 7 8
1 2 3 4
1
2
3
4
5
6
7
8
Blue Red +
Orange
White-Orange
Brown
White-Brown
Green
White-Green
Speaker unit
item 335902
Power
5 6 7 8
Sound
1 2 3 4
Bus
PL PL C S+ S-
Video
Cable art. 336900
opening
door lock
pushbutton
18V
4A impulsive
Terraneo
9
71
INSTALLATION
The system configures itself on typing the Macrocommand
8 2
0
from any extension. For more information consult the Video distributor manual.
Main I.S.
Telephone + Pivot Video
1 Blue 2 Red +
3 Orange
4 White-Orange
7 Green
8 White-Green
1 yellow
GND
2 green
+V
3 blue
tel. line
4 white
ltel. line
5 brown
sound
6 red
acc.
7 black
VID -
8 grey
VID +
(401)
Telephone + Pivot Video
1 Blue 2 Red +
3 Orange
1 yellow
GND
2 green
+V
3 blue
4 White-Orange
7 Green
8 White-Green
tel. line
4 white
ltel. line
5 brown
sound
6 red
acc.
7 black
VID -
8 grey
VID +
(402)
6
6
6
230V a.c.
50Hz
230V 50Hz
An
PS 3 4 M P T R a b a b 1 2 3 4 7 8 1 2 3 4 7 8
Dg - +
1
2
1
2
Video Distributor
335918
1
2
1
2
1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8
2
Power supply
+
1
OUT
PROGRAMMING PROCEDURE
_
OUT
8
Lift the receiver
336010
R
Type
230V a.c.
50Hz
#
Type
Dial the password (base 1234)
After the confirmation tone
type the Macrocommand:
Aftre the confirmation tone
hang up
2
1
8
#
2
3
4
0
1
#
1
#
PABX 18D
9
72
INSTALLATION
Audio and video system with two calls connected to the dedicated outdoor station.
Téléphone + Pivot Video
1 Blue 2 Red +
230V a.c.
50-60Hz
3 Orange
4 White-Orange
7 Green
PRI
C
NO
8 White-Green
a b a b a b a b a b a b a b a b
1
2
3
4
5
6
7
8
2 Red +
335818
a b
GND
2 green
+V
3 blue
tel. line
4 white
ltel. line
5 brown
sound
6 red
acc.
7 black
VID -
8 grey
VID +
(401)
Téléphone + Pivot Video
1 Blue -
Exchange
U1
1 yellow
3 Orange
4 White-Orange
7 Green
3 4 MP T R
8 White-Green
1 yellow
GND
2 green
+V
3 blue
tel. line
4 white
ltel. line
5 brown
sound
6 red
acc.
7 black
VID -
8 grey
VID +
(402)
Telephone line
6
6
a b
IN
PLT1
OUT
a b
6
230V a.c.
50Hz
230V 50Hz
An
PS 3 4 M P T R a b a b 1 2 3 4 7 8 1 2 3 4 7 8
Dg - +
1
2
1
2
Video Distributor
335918
1
2
3
5 6 7 8
4
1 2 3 4
5
6
7
8
Blue Red +
Orange
White-Orange
Brown
White-Brown
Green
White-Green
Power
1
2
1
2
1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8
Sound
Bus
Video
PROGRAMMING
8
art. 336900
Lift the receiver
Main Outdoor Station
Poste extérieur dédié 1
Camera
module item
332510
Type
Type
N
S
1
5 6 7 8
Speaker unit
item 335902
1 2 3 4
After the confirmation tone
type the Macrocommand:
PL PL C S+ S-
opening
door lock
pushbutton
Dial the password (base 1234)
18V
4A impulsive
Aftre the confirmation tone
hang up
Terraneo
9
73
INSTALLATION
The system configures itself on typing the Macrocommand
8 2
1
from any extension. For more information consult the Video distributor manual.
Telephone + Pivot Video
1 Blue 2 Red +
3 Orange
4 White-Orange
6
7 Green
8 White-Green
1 yellow
GND
2 green
+V
3 blue
tel. line
4 white
tel. line
5 brown
sound
6 red
acc.
7 black
VID -
8 grey
VID +
(403)
Telephone + Pivot Video
1 Blue 2 Red +
3 Orange
4 White-Orange
6
7 Green
8 White-Green
1 yellow
GND
2 green
+V
3 blue
tel. line
4 white
tel. line
5 brown
sound
6 red
acc.
7 black
VID -
8 grey
VID +
(404)
Telephone + Pivot Video
1 Blue 2 Red +
3 Orange
4 White-Orange
6
7 Green
8 White-Green
1 yellow
GND
2 green
+V
3 blue
tel. line
4 white
tel. line
5 brown
sound
6 red
acc.
7 black
VID -
8 grey
VID +
(405)
Telephone + Pivot Video
1 Blue 2 Red +
PS a b a b a b a b a b a b 1 2 3 4 7 8 1 2 3 4 7 8 1 2 3 4 7 8
- + 3
4
5
6
7
8
3
4
5
Video Expander
335925
0
1 2 3 4 5 6 7 8 1 2 7 8
6
3 Orange
4 White-Orange
7 Green
8 White-Green
7
1 Blue 3 Orange
4 White-Orange
7 Green
6
6
8 White-Green
1 Blue 3 Orange
4 White-Orange
6
7 Green
8 White-Green
#
2
1
8
#
2
3
4
1
7
#
+V
3 blue
tel. line
4 white
tel. line
5 brown
sound
6 red
acc.
7 black
VID -
8 grey
VID +
(408)
1 yellow
GND
2 green
+V
3 blue
tel. line
4 white
tel. line
5 brown
sound
6 red
acc.
7 black
VID -
8 grey
VID +
(407)
Telephone + Pivot Video
2 Red +
R
GND
2 green
Telephone + Pivot Video
8
1 2 3 4 7 8 1 2 3 4 7 8 1 2 3 4 7 8
2 Red +
PROCEDURE
1 yellow
1 yellow
GND
2 green
+V
3 blue
tel. line
4 white
tel. line
5 brown
sound
6 red
acc.
7 black
VID -
8 grey
VID +
(406)
7
#
PABX 18D
9
74
INSTALLATION
Audio and video system, with one call, connected to the floor distributor of the analog or digital
system
Telephone
a
b
230V a.c.
50-60Hz
PRI
C
NO
a b a b a b a b a b a b a b a b
1
2
3
4
5
6
7
8
1.............. 4.............. 7..............
2.............. 5.............. 8..............
3.............. 6.............. 9..............
(403)
Exchange
335818
U1
a b
3 4 MP T R
6
Telephone line
a b
IN
PLT1
OUT
a b
Analog-Digital system
to the floor distribution
PE
8
Terraneo
9
75
INSTALLATION
The system configures itself on typing the Macrocommand
8 2
0
from any extension. For more information consult the Video distributor manual.
3
#
Main I.S.
Telephone + Pivot Video
1 Blue 2 Red +
3 Orange
4 White-Orange
7 Green
8 White-Green
1 yellow
GND
2 green
+V
3 blue
tel. line
4 white
ltel. line
5 brown
sound
6 red
acc.
7 black
VID -
8 grey
VID +
(401)
Telephone + Pivot Video
1 Blue 2 Red +
3 Orange
Digital
4 White-Orange
Analog
6
8 White-Green
GND
2 green
+V
3 blue
tel. line
4 white
ltel. line
5 brown
sound
6 red
acc.
7 black
VID -
8 grey
VID +
(402)
6
230V a.c.
50Hz
230V 50Hz
7 Green
6
1 yellow
An
PS 3 4 M P T R a b a b 1 2 3 4 7 8 1 2 3 4 7 8
Dg - +
1
2
1
2
Video Distributor
335918
1
2
1
2
1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8
PROGRAMMING PROCEDURE
Lift the receiver
R
Type
#
Type
Dial the password (base 1234)
After the confirmation tone
type the Macrocommand:
Aftre the confirmation tone
hang up
2
1
8
#
2
3
4
0
3
#
PABX 18D
9
76
INSTALLATION
Audio and video system, with one call, connected to the of the analog or digital riser
~
230 V
Telephone line
PRI
Warning: connect
the exchange and
telephone
protection (PLT1)
earth terminal to
the earth of the
electric system
a b
IN
C
NO
a b a b a b a b a b a b a b a b
1
2
3
4
5
6
7
8
Exchange
PLT1
335818
OUT
a b
U1
a b
3 4 MP T R
34
Warning: interface item
335910 must be located
as close as possible to
the exchange (max.
distance 1 m)
Interface
335910
1 2 3 4 5 6 2
Analog or digital system to
the floor distribution
7
8
8
Warning: Interface item 335910 must be set up as a function of the system to which it is connected
ON
ON
1 2 3 4
Analog system
1 2 3 4
Digital system
Note: as a base the interface is supplied to be connected to an analog system.
Terraneo
9
77
INSTALLATION
Main telephone + Pivot Video
1 yellow
2 green
3 blue
4 white
5 brown
6 red
7 black
8 grey
GND
+V
tel. line
tel. line
BELL
ACC.
VID
VID +
1..............
2..............
3..............
4..............
5..............
6..............
7..............
8..............
9..............
1
2
3
4
5
6
R
7
8
9
RP
M1
0
(401)
Telephone 2
1.............. 4.............. 7..............
a
b
2.............. 5.............. 8..............
3.............. 6.............. 9..............
(402)
Telephone 3
1..............
2..............
3..............
4..............
5..............
6..............
7..............
8..............
a
b
9..............
1
2
3
M1
4
5
6
R
7
8
9
RP
0
(403)
Note: in mixed audio and video systems the “self-switching on of the outdoor station” service can only be
activated from telephones with video section.
PABX 18D
9
78
INSTALLATION
Audio and video system with two door entry calls connected to the analog or digital riser
~
230 V
Telephone line
Warning: connect
the exchange and
telephone
protection (PLT1)
earth terminal to
the earth of the
electric system
PRI
C
NO
a b
IN
a b a b a b a b a b a b a b a b
1
2
3
4
5
6
7
8
Exchange
335818
PLT1
OUT
a b
U1
a b
3 4 MP T R
34
Interface
335910
call 1
1 2 3 4 5 6 2
8
7
Call 1
Analog or digital system to
the floor distribution
8
8
Call 2
Warning: Interface item 335910 must be set up as a function of the different types of system, by
means of dip-switches, as follows:
ON
ON
1 2 3 4
Door entry call 1
analog system
ON
ON
1 2 3 4
Door entry call 2
analog system
1 2 3 4
Door entry call 1
digital system
1 2 3 4
Door entry call 2
digital system
Terraneo
9
79
INSTALLATION
To telephones 404 – 406 – 408
To telephones 403 – 405 – 407
Door entry call 1
Telephone + Pivot Video
1
2
3
4
5
6
7
8
yellow
green
blue
white
brown
red
black
grey
GND
V
tel. line
tel. line
BELL
ACC.
VID
VID
1..............
2..............
3..............
+
+
4..............
5..............
6..............
7..............
8..............
9..............
1
2
3
M1
4
5
6
R
7
8
9
RP
0
(401)
Door entry call 2
Telephone + Pivot Video
1
2
yellow
green
3
4
5
6
7
8
blue
white
brown
red
black
grey
GND
V
tel. line
tel. line
BELL
ACC.
VID
VID
1..............
2..............
+
+
3..............
4..............
5..............
6..............
7..............
8..............
9..............
1
2
3
4
5
6
R
7
8
9
RP
M1
0
(402)
34
Interface
335910
call 2
Warning: interface item
335910 must be located
as close as possible to
the exchange (max.
distance 1 m)
1 2 3 4 5 6 2
7
8
Note: in mixed audio and video systems the “self-switching on of the outdoor station” service can only be
activated from telephones with video section.
PABX 18D
9
80
INSTALLATION
Audio and video system with one door entry call connected to the analog or digital riser.
~
230 V
Telephone line
PRI
Warning: connect
the exchange and
telephone
protection (PLT1)
earth terminal to
the earth of the
electric system
C
NO
a b
IN
a b a b a b a b a b a b a b a b
1
2
3
4
5
6
7
8
Exchange
PLT1
335818
OUT
a b
U1
a b
3 4 MP T R
34
Interface
335910
Warning: interface item
335910 must be located
as close as possible to
the exchange (max.
distance 1 m)
1 2 3 4 5 6 2
Analog or digital system to the
floor distribution
7
8
8
Video
distributor
item
336810
Video
distributor
item
336810
PI
OUT
IN
PI
OUT
IN
8
7
8
7
8
7
2
1
8
7
8
7
8
7
2
1
Warning: Interface item 335910 must be set up as a function of the system to which it is connected
ON
ON
1 2 3 4
Analog system
1 2 3 4
Digital system
Note: as a base the interface is supplied to be connected to an analog system.
Terraneo
9
81
INSTALLATION
Telephone + Pivot Video
1 yellow
2 green
3 blue
4 white
5 brown
6 red
7 black
8 grey
GND
+V
tel. line
tel. line
BELL
ACC.
VID
VID +
1..............
2..............
3..............
4..............
5..............
6..............
7..............
8..............
9..............
1
2
3
M1
4
5
6
R
7
8
9
RP
0
(401)
Telephone + Pivot Video
1 yellow
2 green
3 blue
4 white
5 brown
6 red
7 black
8 grey
GND
+V
tel. line
tel. line
BELL
ACC.
VID
VID +
1..............
2..............
3..............
4..............
5..............
6..............
7..............
8..............
9..............
1
2
3
M1
4
5
6
R
7
8
9
RP
0
(402)
Telephone 3
a
b
1.............. 4.............. 7..............
2.............. 5.............. 8..............
3.............. 6.............. 9..............
(403)
Note: in mixed audio and video systems the “self-switching on of the outdoor station” service can only be
activated from telephones with video section.
PABX 18D
9
9.7
82
INSTALLATION
SYSTEM TYPE APPROVAL
After completing the installation and connection operations, perform the tests described below carefully,
to check that the telephone lines and extensions are wired correctly and that the exchange is working
properly.
1. Connect the telephones and the telephone line.
2. With the system switched off lift the receiver of telephone 401; you should hear the telephone
exchange dial tone.
This checks emergency operation in which telephone 401 is directly connected on telephone line.
3. Switch on. The green LED should come on immediately and then after a few seconds the red LED
should shine steadily. If the red LED flashes, the exchange is not switched on correctly; make sure
that the connector of accessory item 335919 has not been put into the IOIOI port.
4. Lift the receiver of telephone 401 and press R; you should hear a continuous tone.
5. Dial 402: this makes an internal call to extension 402; answer from telephone 2 and check the
sound connection between the two telephones.
6. Repeat the same operation for all the telephones connected to the exchange.
7. Soulever le combiné du téléphone n° 401; on doit entendre la tonalité libre du standard
téléphonique.
8. Lift the receiver of telephone 401; you should hear the telephone exchange dial tone.
9. Check the door entry services; open door lock, switch on staircase light and self-switching on of
the outdoor station.
Terraneo
10
83
TABLEAUX RECAPITULATIFS
PERSONALISING THE SYSTEM FOR HOUSE-AUTOMATION SCENARIO…
link with command 31…
Personalisation
Receive incoming telephone calls on Telephone 1
Receive incoming telephone calls on Telephone 2
Receive incoming telephone calls on Telephone 3
Receive incoming telephone calls on Telephone 4
Receive incoming telephone calls on Telephone 5
Receive incoming telephone calls on Telephone 6
Receive incoming telephone calls on Telephone 7
Receive incoming telephone calls on Telephone 8
Telephone 1 enabled for outgoing telephone calls
Telephone 2 enabled for outgoing telephone calls
Telephone 3 enabled for outgoing telephone calls
Telephone 4 enabled for outgoing telephone calls
Telephone 5 enabled for outgoing telephone calls
Telephone 6 enabled for outgoing telephone calls
Telephone 7 enabled for outgoing telephone calls
Telephone 8 enabled for outgoing telephone calls
Line 1
PABX 18D
10
84
TABLEAUX RECAPITULATIFS
Programming
Receive door entry calls on Telephone 1
Receive door entry calls on Telephone 2
Receive door entry calls on Telephone 3
Receive door entry calls on Telephone 4
Receive door entry calls on Telephone 5
Receive door entry calls on Telephone 6
Receive door entry calls on Telephone 7
Receive door entry calls on Telephone 8
Telephone 1 enabled door entry
functions
Telephone 2 enabled door entry
functions
Telephone 3 enabled door entry
functions
Telephone 4 enabled door entry
functions
Active
Not active
Telephone exchange
PABX 18D
Terraneo
85
Expandability
The basic telephone Exchange
functions can be expanded,
adding a series of devices which
increase its performance.
Expansion modules and accessories
Video distributor (item 335918)
Video expander (item 335925)
Relay expansion module (item 335916)
Door entry interface module for analog and digital systems
(item 335910)
Door entry interface module for the 2-wire system (item 346810)
Dedicated speaker unit for PABX (item 335902)
PABX 18D
11
86
EXPANDABILITY
11.1 VIDEO DISTRIBUTION (ITEM 335918)
The video distributor with the PABX telephone exchanges (item 335818 or 335828 produced from batch
0127 6) and its star wiring can quickly and easily produce single or two-family video door entry telephone
systems, with one or two divisions. Using the distributor means that all the telephones with video section
not only provide all the door entry and telephone services but also provide CCTV of communal and/or
private areas.
The following can be directly connected to the distributor:
Up to two telephones with video function (video door entry telephones)
Up to two dedicated video outdoor stations (speaker unit item 335902 and camera module item
332510)
Up to two calls from the same analog or digital floor distribution block. Up to 4 riser OS can be
connected in the analog system; up to 15 in the digital system.
EXAMPLE OF A SYSTEM WHICH CAN BE MADE USING THE VIDEO DISTRIBUTOR
IS
1..............
1..............
2..............
2..............
3..............
3..............
4..............
4..............
5..............
5..............
6..............
6..............
7..............
2
8..............
9..............
1
2
3
M1
4
5
6
R
7
8
9
RP
7..............
6
8..............
9..............
0
1
2
3
4
5
6
R
7
8
9
RP
M1
0
2
IS
1..............
2..............
PRI
C
NO
(230V~ 50Hz)
a
1
b a
2
b a
3
ba
4
b a
5
b a
6
b a
7
ba
8
3..............
b
4..............
5..............
6..............
230V~ 50Hz
6A
2A
M
COS
= 0,5
2
spa
7..............
6
PC
FAX
8..............
9..............
1
2
3
4
5
6
R
7
8
9
RP
M1
0
PABX 28D cod. 335818
230V
335818
15% 0,15 A 50 Hz
Patent Pending
AUX
EXP
a
U1
b
3 4 M PTR
6
MAXIMUM DISTANCE BETWEEN DEVICES
When making the systems the maximum distances given
in the table below must be respected. The distances
indicated refer to the use of cable item 336900.
230V
50 Hz
An
Dg
PS
1
PABX
+ 3 4 M P T R a
b
a
2
b
1 2 3 4 7 8 1 2 3 4 7 8
spa
MAXIMUM DISTANCE BETWEEN THE DEVICES WITH CABLE item 336900
335918
230V
From the Video Distributor
To the video telephone
door entry IS
10% 50
60 Hz
0,15 A
200 metres
1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8
From the Video Distributor
To the dedicated OS or
extra cameras
200 metres
OS 2
OS 1
8
8
Terraneo
11
87
EXPANDABILITY
11.2
VIDEO EXPANDER (ITEM 335925)
The video expander with the video distributor item 335918 and the PABX telephone exchanges (item
335818 and 335828 produced from batch 0127 6) can further expand the video door entry telephone
system.
The following can be directly connected to the video expander:
- Up to 6 telephones with video function (video door entry telephones)
- 1 dedicated video outdoor station (speaker unit item 335902 and camera module item 332510) if
there are no calls from analog or digital riser OS.
- 1 camera from the following:
- Separate (item 391600/1/2); Dome (item 391603);
- In Living, Light or Light Tech version (item 391612/3/4)
Note: The cameras listed above cannot be used as an alternative to the dedicated OS
EXAMPLE OF A SYSTEM WHICH CAN BE MADE USING THE VIDEO EXPANDER
IS
1..............
2..............
3..............
4..............
6
5..............
6..............
7..............
8..............
9..............
1
2
3
M1
4
5
6
R
7
8
9
RP
0
1..............
2..............
3..............
4..............
5..............
6..............
IS
7..............
8..............
9..............
1
2
3
M1
4
5
6
R
7
8
9
RP
0
PRI
C
230V~ 50Hz
NO
6A
2A
(230V~ 50Hz)
M
COS
a
= 0,5
1
b a
2
b a
3
ba
4
b a
5
b a
6
b a
7
ba
8
2..............
3..............
4..............
5..............
6..............
7..............
8..............
9..............
1
2
3
4
5
6
R
7
8
9
RP
M1
0
PC
FAX
spa
1..............
2..............
3..............
4..............
5..............
IS
6..............
7..............
PABX 28D cod. 335818
230V
1..............
6
b
8..............
9..............
1
335818
2
3
M1
4
5
6
R
7
8
9
RP
0
15% 0,15 A 50 Hz
1..............
2..............
3..............
6
Patent Pending
AUX
EXP
a
U1
b
4..............
5..............
6..............
7..............
8..............
9..............
1
2
3
M1
4
5
6
R
7
8
9
RP
0
3 4 M PT R
6
1..............
2..............
3..............
4..............
5..............
6..............
7..............
8..............
9..............
6
230V
50 Hz
An
Dg
PS
+
3
4
PABX
M
P
T
R
1
a
b
a
2
b
6
1 2 3 4 7 8 1 2 3 4 7 8
1
+
a
3
b
a
4
b
a
5
b
a
6
b
a
7
b
a
8
b
3
M1
5
6
R
8
9
RP
0
6
PS
2
4
7
1 2 3 4 7 8 1 2 3 4 7 8 1 2 3 4 7 8
1..............
2..............
3..............
4..............
5..............
6..............
7..............
335918
230V
10% 50
9..............
1
2
3
4
5
6
R
7
8
9
RP
335925
60 Hz
M1
0
0,15 A
1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8
OS 1
8..............
spa
spa
1 2 3 4 5 6 7 8 1 2
7 8
1 2 3 4 7 8 1 2 3 4 7 8 1 2 3 4 7 8
1..............
2..............
3..............
4..............
5..............
6..............
7..............
8..............
9..............
1
6
8
OS 3
8
8
3
M1
5
6
R
8
9
RP
0
6
OS 2
2
4
7
PABX 18D
11
11.3
88
EXPANDABILITY
RELAY EXPANSION MODULE (ITEM 335916)
Each exchange can manage a maximum of 8 relays in addition to the internal relay for switching on the
staircase light. A maximum of 2 item 335916 can thus be connected.
Dimensions 3 DIN modules
Contact output: 6 A resistive, 2 A inductive at cos j 0.5, voltage 230 V.a.c.
The maximum output of 1 terminal C is 8 A.
Note: the distance between the exchange and expansion modules item 335916 must be less than 1
metre. The cable to be used to make the connections must be of section 0.28 mm2 or greater.
As a base the extra relays are programmed to operate in monostable mode (cannot be activated with
or R8)
BASE RELAY
PRI
C
230V~ 50Hz
NO
6A
2A
(230V~ 50Hz)
M
COS
a
= 0,5
1
b a
2
b a
3
ba
4
b a
5
b a
6
b a
7
ba
8
b
PC
FAX
spa
PABX 18D cod. 335818
230V
335818
15% 0,15 A 50 Hz
Patent Pending
AUX
EXP
a
U1
b
a
U2
3 4 M PTR
b
12V~ M P T T1
IN
12V~ M P T T1
IN
OUT
spa
PABX 28D cod. 335916
335916
max
16A
230V~
C C 1 2 3 4
6A
2A
M
COS
= 0,5
OUT
spa
PABX 28D cod. 335916
335916
B9743A
0114 06
C C 1 2 3 4
ACTUATOR
RELAY
max
16A
230V~
6A
2A
M
COS
= 0,5
B9743A
0114 06
C C 1 2 3 4
ACTUATOR
RELAY
230 Vac
activ. 9911
deactiv. 9901
activ. 9912
deactiv. 9902
activ. 9913
deactiv. 9903
activ. 9914
deactiv. 9904
Note: If there are two expansion modules for 4 extensions item 335912, two expansion modules for
telephone line item 335913 and three dedicated speaker units item 335902, the expansion modules for
actuation/remote operation item 335916 must be supplied with a separate transformer (see diagram on
the instructions with item 335916).
Terraneo
11
89
EXPANDABILITY
11.4 DOOR ENTRY INTERFACE MODULE FOR ANALOG AND DIGITAL
SYSTEMS (ITEM 335910)
This module must be used to connect the exchange to a riser, in both analog and digital systems. The
interface is supplied set up for analog riser. If installed on a digital riser position dip-switch 3 on ON.
Dimensions 3 DIN modules
POTENTIOMETER ADJUSTMENT
LOUDSPEAKER VOLUME
DIP SWITCH
FOR ANALOG SYSTEM
POTENTIOMETER ADJUSTMENT
MICROPHONE VOLUME
ON
1 2 3 4
CONNECT TO TERMINALS 3 AND 4
OF THE TELEPHONE EXCHANGE
3 4
ON
1
PBX
2
3
4
1234
FOR DIGITAL SYSTEM
ON
1 2 3 4
1 Open door lock
spa
PABX 28D cod. 335910
335910
2 Interface
off = door entry call 1
B9737B
1001 06
IN
off = 2 seconds
on =10 seconds
1 2 3 4 5 6 2
on = door entry call 2
3 System
off = analog
on = digital
4 Not used
To the floor distribution
Analog or digital system
PABX 18D
11
90
EXPANDABILITY
11.5 DOOR ENTRY INTERFACE MODULE FOR THE 2-WIRE SYSTEM
(ITEM 346810)
This interface module must be used to connect the exchange to the riser of the 2-wire system, both audio
and video.
The interface must be suitably configured.
Dimensions 3 DIN modules
6
3
Exchange Art. 335828
4 M P T R
P:
N:
AUX
346810
indicates on which outdoor station key
acts with system idle
assigns the correspondence for the 1st
door entry call
N1: assigns the correspondence for the 2nd
door entry call (optional)
NN
2 FILI
P
NN1
S C S
2-wire system
Warning: Correct operation of the 2-wire interface is guaranteed using PABX exchanges 335818
and 335828 produced with production batch 0139 6 or later or, if previous, updating it with TIPBX
software ver. 4.1 or later; item 335916 (relay module) instead can only be used with the 2-wire
interface if produced with production batch 0116 6 or later.
Terraneo
11
91
EXPANDABILITY
Activating 2-wire interface from extension
The following procedure must be performed to activate the 2-wire interface:
Lift the receiver
Press the
Type:
R
#
key, you will hear the start-dialling tone
#
Dial the password (e.g. base
1
2
3
4
)
After the start dialling tone type the Macrocommand:
8
2
9
0
#
After receiving the confirmation tone, hang up.
Deactivating 2-wire interface from extension
Pour la désactivation de l’interface 2 fils il faut exécuter la procédure suivante:
Lift the receiver
Press the
Type:
#
R
key, you will hear the start-dialling tone
#
Dial the password (e.g. base
1
2
3
4
)
After the start dialling tone type the Macrocommand:
7
7
0
0
#
After receiving the confirmation tone, hang up.
Activating door lock on Outdoor Station XY of the riser
R
4
X Y
Intercommunication with Indoor Station XY of the riser
R
X Y
PABX 18D
11
11.6
92
EXPANDABILITY
DEDICATED SPEAKER UNIT FOR PABX (ITEM 335902)
A maximum of three speaker units item 335902 can be connected to each PABX exchange and a
nameplate module item 342200 can be connected to one of the speaker units.
Up to 3 outdoor stations can be connected without mixer. One of the three outdoor stations can have a
nameplate module for street number or other information. The speaker units of outdoor stations 1 and 2
must be configured. The speaker unit of the main outdoor station must not be configured.
Operation
The system automatically switches to the outdoor station from which the call was made. If a call is made
from one of the two temporarily excluded speaker units you will hear a telephone busy tone.
Idle the door lock command acts on the main outdoor station.
As a base the staircase light button of the speaker unit is associated to the exchange relay; it can however
be associated to one of the relays of expansion item 335916 if so programmed.
A twisted cable with minimum section 0.28 mm2 must be used for the connection between speaker unit
and PABX.
11.7
INSTALLING THE SPEAKER UNIT
1
2
2
1
3
cm
160 - 165
1
2
Terraneo
11
93
EXPANDABILITY
Installing the speaker unit with nameplate module (item 342200)
A nameplate module for item 342200 can be connected to the speaker unit to show the street number or
other information.
2
1
1
2
Installing the speaker unit and camera (item 332520)
Camera module item 332520 can be connected to the speaker unit to make video systems.
2
1
3
The camera can be rotated for optimum view
20°
1
3
-20× Þ +20×
20°
2
-20× Þ +20×
PABX 18D
11
94
EXPANDABILITY
Connecting the electric door lock to the outdoor station
332510
342200
PL PL C S+ S-
2 seconds
Extra
pushbutton to
open door lock
A
PL PL C S+ S-
J1
N S
J2
10 seconds
B
Extra
pushbutton to
open door lock
J1
J2
N S
7
230 Vac
11.7 ACCESSORY FOR PROGRAMMING FROM PC (ITEM 335919)
The “TIPBX” software, together with the accessory for programming from PC (item 335919) can be used
for easier exchange programming.
The “TIPBX” programming software can be downloaded free from the BTicino Internet site, address
www.bticino.it software section.
Exchanges item 335828 produced from batch 0127 6 can work together with video Distributor item
335918 and Video Expander item 335925; to program systems of this type the “TIPBX” software must be
version 3.1 or later.
Terraneo
12
12.1
95
TECHNICAL DATA
TECHNICAL CARD
Installation:
on DIN rail with size 10 DIN modules
Capacity:
Outside telephone line (analog)
Extensions
1
8
Connection system:
Telephone connection
Maximum telephone distance
Outside telephone line connection
Max distance between PABX and item 335902
two-wire (with 0.28 mm2 telephone pair)
200 m
two-wire (with 0.28 mm2 telephone pair)
200 m two-wire (with 0.28 mm2 telephone pair)
Dialling system:
pulse-dial or touch-tone
Power supply:
Network voltage
Power required
Dissipated power
230 V a.c. ±10%
20 VA
12 W
Staircase light relay contact:
6 A resistive – 2 A inductive 230 V c.a.
Protection against overvoltage
and overcurrent on telephone line:
earth leakage integrated and common mode with
earth conductor on terminal
Mechanical and environmental characteristics:
Weight
900 gr
Working temperatures
0 °C - 40 °C
Timing of internal tones: (*)
start dialling tone
call control tone (free)
busy tone
time-out tone
overcrowded tone
on-hold tone
alerting tone
confirmation tone
configuration error tone
door entry on-hold tone
door entry call alerting tone
continuous two-tone
1s/4s
500 ms / 500 ms
100 ms / 100 ms
200 ms / 200 ms
200 ms / 200 ms / 200 ms / 3400 ms
100 ms / 4900 ms
100 ms / 100 ms / 100 ms / 100 ms / 100 ms / 1500 ms
100 ms / 100 ms / 300 ms / 300 ms / 500 ms / 2 s
200 ms / 100 ms / 200 ms / 100 ms / 500 ms / 2 s
100 ms / 100 ms / 100 ms / 4700 ms
Call signals (bell rhythms): (*)
extension call
local call
door entry call
600 ms / 200 ms / 200 ms / 4 s
1s / 4 s
400 ms / 400 ms / 400 ms / 400 ms / 400 ms / 1s
Programming the services:
from any extension or by PC from IOIOI connector
Emergency service: If there is a power cut, telephone 401 gives direct access to outside telephone line.
(*) Note: The times are given in the sequence pulse / pause / pulse / pause / etc.
PABX 18D
96
12 TECHNICAL DATA
12.2 STANDARDS REFERENCES
The item which is the subject of the manual comes with EC Declaration of conformity
according to the requirements indicated below:
BTicino S.p.A. Via Messina, 38 – 21154 MILAN declares that the product with item
No.:
335818
conforms to the essential requirements of directive 1999/5/EC in that it respects the
following standards:
EN 60950
EN 50081-1
ETSI TBR21
ETSI ES 201 187 V 1.1.1
EN 50082-1
Year of Approval EC marking according to the directive indicated: 2001
Terraneo
97
NOTES
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
PABX 18D
98
NOTES
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
BTicino s.p.a.
Via Messina, 38
20154 MILAN - Italy