Download User manual

Transcript
μC3
Menu description
SMS send test:
Extended description
Min/max limits
Send test SMS (an SMS is sent with a test message)
N/Y
SMS send enable:
Enable send SMS in response to an alarm
N/Y
EXTERNAL MODEM
GSM MODEM
Status:
Status of the modem
Field:
Percentage of signal reception for the GSM modem
Ext. modem standby
Initialisation
Search GSM network
Modem standby
Modem alarm
Init. error
Enable PIN
GSM network not found
SMS saturation
Send SMS…
Modem connected…
Modem calling...
0 to 100
Temporary modem error
Temp. error
Permanent modem error
Perm. error
Unit of
measure
Default
Access
Supervisor
address
Ana/I
nt/Dig
R/
R-W
user
Y
user
%
Time next call
Waiting time for new call after failed attempt
0
Language mask
visualization
on start
Reset eventi SMS
Enable display of change language screen when starting unit
N/Y
Y
user
Delete list of SMS messages sent or to be sent
N/Y
N
manufacturer
Restore
default values
Condensation
Regulation type
Start board memory delete procedure and restore default values
N/Y
N
manufacturer
Type of condenser control
PRESSURE
manufacturer
INT
37
RW
Condensation
Condenser number
Condensation
Devices type
Condensation
Fans number
Fans type
Frequency
Cond.fan forcing
time on start
PWM Phase cut
Triac max.:
PWM Phase cut
Triac min.:
PWM Phase cut
Range wave:
Fan parameters
summer
Setpoint
Fan parameters
summer
Diff.
Fan parameters
winter
Setpoint
Fan parameters
winter
Diff.
Fan
minimum speed
diff.
Inverter
Max.speed
Inverter
Min.speed
Inverter
Speed-up time
HP prevent
Enabled
HP prevent
Probe
HP prevent
(cooling mode)
Setpoint
HP prevent
(cooling mode)
Diff.
LP prevent
(heating mode)
Setpoint
LP prevent
(heating mode)
Diff.
Number of condensers installed
CIRC.ON/OFF STATUS
PRESSURE
TEMPERATURE
1
2
INVERTER
FANS
1 to 4
1
manufacturer
DIG
3
RW
INVERTER
manufacturer
DIG
21
RW
1
manufacturer
INT
38
RW
Type of condensing devices controlled
Total number of fans installed
Frequency of power supply for fan control by inverter
s
0
Hz
50
manufacturer
Forcing time when starting the condenser (temperature control)
50
60
0 to 999
s
0
manufacturer
Maximum voltage threshold for Triac
0 to 100
%
75
manufacturer
Minimum voltage threshold for Triac
0 to 100
%
25
manufacturer
Amplitude impulse for phase control
0.0 to 10.0
ms
2.5
manufacturer
Condensing set point (cooling)
0.0 to 99.9
°C/bar
14.0
user
ANA
11
RW
Condenser differential (cooling)
-99.9 to 99.9
°C/bar
2.0
user
ANA
12
RW
Evaporation set point (heating)
0.0 to 99.9
°C/bar
14.0
user
Evaporation differential (heating)
-99.9 to 99.9
°C/bar
2.0
user
Differential for fan operation at minimum speed
-99.9 to 99.9
°C/bar
5.0
user
Maximum fan speed with inverter
0.0 to 10.0
V
10.0
manufacturer
Minimum fan speed with inverter
0.0 to 10.0
V
0.0
manufacturer
Speed-up time with inverter
0 to 999
s
30
manufacturer
INT
39
RW
Enable high pressure prevent
N/Y
N
manufacturer
Select the prevent probe
PRESSURE
manufacturer
High pressure prevent set point (cooling)
PRESSURE
TEMPERATURE
-99.9 to 99.9
°C/bar
20.0
user
High pressure prevent differential (cooling)
0 to 99.9
°C/bar
2.0
user
Low pressure prevent set point (heating)
-99.9 to 99.9
°C/bar
3.0
user
Low pressure prevent differential (heating)
0 to 99.9
°C/bar
2.0
user
+030220431 rel 1.5 16/11/2009
34