μC3 Menu description SMS send test: Extended description Min/max limits Send test SMS (an SMS is sent with a test message) N/Y SMS send enable: Enable send SMS in response to an alarm N/Y EXTERNAL MODEM GSM MODEM Status: Status of the modem Field: Percentage of signal reception for the GSM modem Ext. modem standby Initialisation Search GSM network Modem standby Modem alarm Init. error Enable PIN GSM network not found SMS saturation Send SMS… Modem connected… Modem calling... 0 to 100 Temporary modem error Temp. error Permanent modem error Perm. error Unit of measure Default Access Supervisor address Ana/I nt/Dig R/ R-W user Y user % Time next call Waiting time for new call after failed attempt 0 Language mask visualization on start Reset eventi SMS Enable display of change language screen when starting unit N/Y Y user Delete list of SMS messages sent or to be sent N/Y N manufacturer Restore default values Condensation Regulation type Start board memory delete procedure and restore default values N/Y N manufacturer Type of condenser control PRESSURE manufacturer INT 37 RW Condensation Condenser number Condensation Devices type Condensation Fans number Fans type Frequency Cond.fan forcing time on start PWM Phase cut Triac max.: PWM Phase cut Triac min.: PWM Phase cut Range wave: Fan parameters summer Setpoint Fan parameters summer Diff. Fan parameters winter Setpoint Fan parameters winter Diff. Fan minimum speed diff. Inverter Max.speed Inverter Min.speed Inverter Speed-up time HP prevent Enabled HP prevent Probe HP prevent (cooling mode) Setpoint HP prevent (cooling mode) Diff. LP prevent (heating mode) Setpoint LP prevent (heating mode) Diff. Number of condensers installed CIRC.ON/OFF STATUS PRESSURE TEMPERATURE 1 2 INVERTER FANS 1 to 4 1 manufacturer DIG 3 RW INVERTER manufacturer DIG 21 RW 1 manufacturer INT 38 RW Type of condensing devices controlled Total number of fans installed Frequency of power supply for fan control by inverter s 0 Hz 50 manufacturer Forcing time when starting the condenser (temperature control) 50 60 0 to 999 s 0 manufacturer Maximum voltage threshold for Triac 0 to 100 % 75 manufacturer Minimum voltage threshold for Triac 0 to 100 % 25 manufacturer Amplitude impulse for phase control 0.0 to 10.0 ms 2.5 manufacturer Condensing set point (cooling) 0.0 to 99.9 °C/bar 14.0 user ANA 11 RW Condenser differential (cooling) -99.9 to 99.9 °C/bar 2.0 user ANA 12 RW Evaporation set point (heating) 0.0 to 99.9 °C/bar 14.0 user Evaporation differential (heating) -99.9 to 99.9 °C/bar 2.0 user Differential for fan operation at minimum speed -99.9 to 99.9 °C/bar 5.0 user Maximum fan speed with inverter 0.0 to 10.0 V 10.0 manufacturer Minimum fan speed with inverter 0.0 to 10.0 V 0.0 manufacturer Speed-up time with inverter 0 to 999 s 30 manufacturer INT 39 RW Enable high pressure prevent N/Y N manufacturer Select the prevent probe PRESSURE manufacturer High pressure prevent set point (cooling) PRESSURE TEMPERATURE -99.9 to 99.9 °C/bar 20.0 user High pressure prevent differential (cooling) 0 to 99.9 °C/bar 2.0 user Low pressure prevent set point (heating) -99.9 to 99.9 °C/bar 3.0 user Low pressure prevent differential (heating) 0 to 99.9 °C/bar 2.0 user +030220431 rel 1.5 16/11/2009 34