Motor and feedback mounting
Parker EME
2.3.3.2
IP65 motor mount parallel
The cylinder is furnished with mounted parallel housing. The housing as well as the
motor flange which is fixed to the housing, must be sealed.
 Apply silicone sealing compound to the motor
flange pilot (e.g. Sista Silicone F109 Universal).

Screw motor to motor flange (delivered with the
cylinder),
(see chapter “Motor and gearbox mounting”
(see on page 25)).

Apply silicone sealing compound around bores
of the parallel housing

Mount motor with motor flange to parallel
housing
(see chapter “Motor and gearbox mounting”
(see on page 25)).

Tension toothed belt
(see “Exchange or tension toothed belt”
(see on page 33, see on page 42)).

Place seal (furnished with the cylinder).

Place lid (furnished with the cylinder).

Fix lid and seal to parallel housing

Note the additional mounting steps
(see chapter “Motor and gearbox mounting”
(see on page 25)).
192-550002N6 ETH Mounting Instructions 2015-11