MiiNePort E2 Introduction to SCM (Serial Command Mode) Command Set DIO initial state Command code: PS Command parameters: DIO port index. For the MiiNePort E2, the index is as follows: Index DIO port MiiNePort E2 PIN number 0 DIO0 PIN15 1 DIO1 PIN16 2 DIO2 PIN17 3 DIO3 PIN18 Reply parameters: 1 (high) or 0 (low) , note that this function is configuration only if specific DIO port is set to initial output. ?RPS0 System requests DIO0’s initial state for this MiiNePort. !RPS00 MiiNePort reports DIO0’s initial state as ‘low’. Serial command mode trigger Command code: CT Command parameters: N/A Reply parameters: serial command mode trigger index as shown in the following table. 0 Disabe 1 H/W control pin(DIO1) 2 Activated by characters 3 Activated by break signal Note that this configuration is valid only if port 1’s operation mode is not set to MCSC. ?RCT System requests serial command mode trigger method for this MiiNePort. !RCT01 MiiNePort reports serial command mode is triggered by DIO1. Serial command mode trigger characters Command code: CC Command parameters: N/A Reply parameters: serial command mode trigger characters, in hex, separated by a semicolon (;). Note that this configuration is valid only if serial command mode trigger method is set to `Activated by characters’. ?RCC System requests serial command mode trigger characters for this MiiNePort. !RCC058;58;58 MiiNePort reports serial command mode triggered by `XXX’ (0x585858). A-50