Download OPERATORS MANUAL

Transcript
SYMPTOM
POSSIBLE CAUSE
SOLUTION
Low Velocity First Shot.
DWELL parameter is too low to overcome
stiction on Solenoid and / or Rammer O-rings.
Increase DWELL parameter.
High Velocity First Shot.
DWELL parameter set too high.
Reduce DWELL parameter.
Inline Regulator pressure creeping.
Strip and clean Inline Regulator. Replace Inline
Regulator piston if necessary.
My Trigger is very “Bouncy”, how can I reduce
it?
Too low Debounce setting.
Increase Debounce setting.
Lengthen and strengthen your trigger pull.
Refer to Advanced Set-Up Section for
guidelines of how to adjust your Etek2 Trigger
accordingly.
The Break-Beam Sensor System does not
appear to be reading correctly.
The Break-Beam Sensor System is dirty.
Keep the Break-Beam Sensors clean to
ensure correct readings ( See Maintenance
Section ).
Break-Beam Sensors are the wrong way
around.
Check that the red receiver is on the righthand side of the Breech.
There is a broken wire or contact, or a short
circuit on either of the Breech Sensor ribbon
cables.
Check the plug of the cables.
Either sensor is back to front.
Check that the sensors face each other when
installed.
The Break-Beam Sensor System is not
reading at all.
40
FAULT FINDING
Check for cuts or pinches in the sensor
cables.