SYMPTOM POSSIBLE CAUSE SOLUTION Low Velocity First Shot. DWELL parameter is too low to overcome stiction on Solenoid and / or Rammer O-rings. Increase DWELL parameter. High Velocity First Shot. DWELL parameter set too high. Reduce DWELL parameter. Inline Regulator pressure creeping. Strip and clean Inline Regulator. Replace Inline Regulator piston if necessary. My Trigger is very “Bouncy”, how can I reduce it? Too low Debounce setting. Increase Debounce setting. Lengthen and strengthen your trigger pull. Refer to Advanced Set-Up Section for guidelines of how to adjust your Etek2 Trigger accordingly. The Break-Beam Sensor System does not appear to be reading correctly. The Break-Beam Sensor System is dirty. Keep the Break-Beam Sensors clean to ensure correct readings ( See Maintenance Section ). Break-Beam Sensors are the wrong way around. Check that the red receiver is on the righthand side of the Breech. There is a broken wire or contact, or a short circuit on either of the Breech Sensor ribbon cables. Check the plug of the cables. Either sensor is back to front. Check that the sensors face each other when installed. The Break-Beam Sensor System is not reading at all. 40 FAULT FINDING Check for cuts or pinches in the sensor cables.