Supplement A: Parameter Description 2-91
ECODRIVE03-FGP-01VRS
S-0-0310, Overload warning
This parameter defines an ident number for the overload warning. The
purpose is to be able to assign the overload warning to a real time status
bit. The overload warning is defined as a bit in the Class 2 diagnostics
and is set dependent from the load integral limit. Only the bit 0 is defined.
Structure of the parameter:
Bit 0 :
0: no overload
1: overload warning
Fig. 2-31:
S-0-0310, Overload Warning
S-0-0310 - Attributes
Para. Name:
DE
Überlast Warnung
EN
Overload warning
FR
Alerte surcharge
ES
Aviso sobrecarga
IT
Preallarme Sovracarica
Function:
Parameter
Editability:
no
Data length:
2Byte
Memory:
-
Format:
BIN
Validity check:
no
Extrem value check: no
Unit:
Decimal places:
0
Input min/max:
-/-
Default value:
-
Combination check: no
Cyc. transmittable:
-
S-0-0311, Amplifier overtemperature warning
This parameter defines an ident number for the amplifier
overtemperature warning. The purpose is to be able to assign the
amplifier overtemperature warning to a real time status bit. The amplifier
overtemperature warning is defined as a bit in the Class 2 diagnostics
and is set dependent from the amplifier temperature warning threshold.
Only the bit 0 is defined.
Structure of the parameter:
Bit 0 :
0:
no amplifier overtemperature
1:
amplifier overtemperature
warning
Fig. 2-32:
S-0-0311 Amplifier overtemperature warning
S-0-0311 - Attributes
Para. Name:
DOK-ECODR03-FGP-01VRS**-FKB1-EN-P
DE
Verstärker-Übertemperatur-Warnung
EN
Amplifier overtemperature warning
FR
Alerte surchauffe ampli
ES
Aviso sobretemperatura amplif.
IT
Preallarme Sovratemperatura Drive