Download CERTIFICATION REFERENCE CERTIFICATION

Transcript
Certification reference
"Heat Pump" NF mark
NF 414 Rev 8 – Appendix E
Gas engine-driven HP
11/15
Heat pump equipment (tick the relevant box(es))
Variable speed compressor (Engine speed variation, compressor staging, etc.)
Multiple speed fan. Number: ……
Variable speed fan
Expansion valve with type (thermostatic, electronic, …)
Exchanger cooling operation (free cooling)
Heater
Domestic hot water production included in the HP
Other equipment or accessories:
...................................................................................................................................................
...................................................................................................................................................
If the equipment mentioned below is not installed on all the models, it must be subject to separate
right of use applications. However, we invite you to contact CERTITA to confirm this.
Reversible cycle cooling operation (reversible heat pump)
Passive cooling mode operation
Circulation pump for collectors
Multiple speed circulation pump. Number: ……
Variable speed pump
Circulation pump for the heating circuit
Multiple speed circulation pump. Number: ……
Variable speed pump
Accumulator (buffer tank)
requested operating points:
Depending on the HP categories covered by the application (heating and reversible if appropriate,
swimming pools), the requested operating point shall be detailed in the data and characteristics tables
given below.
Starting point at -15°C :
For Outdoor Air – Water type heat pumps, an HP starting point must be carried out to validate the
operating range. To enable the laboratory to conduct the test, we ask that you specify below the
maximum water temperature, for an outdoor temperature of -15°C. This value will be restated on the NF
mark admission decision for the range.
Maximum water temperature = ………… °C