6. PASSWORDS
For security reasons, the system uses the following types of passwords:
t
SMS password – 4-digit password used for system arming/disarming and configuration by SMS text messages. By default, SMS password is 0000, which MUST be changed!
t
Administrator password – 4-digit password used for Configuration mode activation by keypad and logging in to ELDES Configuration
Tool software. By default, Administrator password is 1470, which is highly recommended to change.
Set SMS password
SMS
EKB2
EKB3W
Config
Tool
This operation may be carried out from the PC using the ELDES Configuration Tool software.
EKB2
Menu path:
OK CONFIGURATION OK 1470 OK PRIMARY SETTINGS OK PASSWORDS
OK ADMIN PASSWORD OK aaaa OK
Value: aaaa – 4-digit new administrator password; range – [0000... 9999].
EKB3/
Enter parameter 16 & new administrator password:
16 aaaa #
EKB3W
Config
Tool
EN50131-1
GRADE 3
Menu path:
OK CONFIGURATION OK aaaa OK PRIMARY SETTINGS OK PASSWORDS
OK SMS PASSWORD OK ssss OK
Value: aaaa – 4-digit administrator password; ssss – 4-digit new SMS password; range –
[0001... 9999].
Enter parameter 14 & new SMS password:
14 ssss #
Value: ssss – 4-digit new SMS password; range – [0001... 9999].
Example: 141111#
EKB3/
Set Administrator
password
SMS text message content:
wwww_PSW_ssss
Value: wwww – 4-digit default SMS password; ssss – 4-digit new SMS password; range –
[0001... 9999].
Example: 0000_PSW_1111
Value: aaaa – 4-digit new administrator password; range – [0000... 9999].
Example: 162538#
This operation may be carried out from the PC using the ELDES Configuration Tool software.
To comply with EN50131-1 Grade 3 standard requirements, the system must be equipped with the following features:
t "MMQBTTXPSETNVTUDPOTJTUPGEJHJUT
t 5IFTZTUFNNVTUQSPNQUGPS4.4BOEBENJOJTUSBUPSQBTTXPSETXIFODPOmHVSJOHUIFTZTUFNVTJOHELDES Configuration
Tool software.
t5IFTZTUFNNVTUQSPNQUGPSVTFSTFF10. USER PASSWORDS) and administrator passwords when configuring the system by EKB2, EKB3, EKB3W keypad.
For complete list of EN50131-1 Grade 3 standard requirements and how to enable/disable the associated features, please
refer to 34. EN 50131-1 GRADE 2.
28
EN
MANUAL ELDES ESIM364 V1.3