Download ESIM364 - tridimas electronics
Transcript
6. PASSWORDS For security reasons, the system uses the following types of passwords: t SMS password – 4-digit password used for system arming/disarming and configuration by SMS text messages. By default, SMS password is 0000, which MUST be changed! t Administrator password – 4-digit password used for Configuration mode activation by keypad and logging in to ELDES Configuration Tool software. By default, Administrator password is 1470, which is highly recommended to change. Set SMS password SMS EKB2 EKB3W Config Tool This operation may be carried out from the PC using the ELDES Configuration Tool software. EKB2 Menu path: OK CONFIGURATION OK 1470 OK PRIMARY SETTINGS OK PASSWORDS OK ADMIN PASSWORD OK aaaa OK Value: aaaa – 4-digit new administrator password; range – [0000... 9999]. EKB3/ Enter parameter 16 & new administrator password: 16 aaaa # EKB3W Config Tool EN50131-1 GRADE 3 Menu path: OK CONFIGURATION OK aaaa OK PRIMARY SETTINGS OK PASSWORDS OK SMS PASSWORD OK ssss OK Value: aaaa – 4-digit administrator password; ssss – 4-digit new SMS password; range – [0001... 9999]. Enter parameter 14 & new SMS password: 14 ssss # Value: ssss – 4-digit new SMS password; range – [0001... 9999]. Example: 141111# EKB3/ Set Administrator password SMS text message content: wwww_PSW_ssss Value: wwww – 4-digit default SMS password; ssss – 4-digit new SMS password; range – [0001... 9999]. Example: 0000_PSW_1111 Value: aaaa – 4-digit new administrator password; range – [0000... 9999]. Example: 162538# This operation may be carried out from the PC using the ELDES Configuration Tool software. To comply with EN50131-1 Grade 3 standard requirements, the system must be equipped with the following features: t "MMQBTTXPSETNVTUDPOTJTUPGEJHJUT t 5IFTZTUFNNVTUQSPNQUGPS4.4BOEBENJOJTUSBUPSQBTTXPSETXIFODPOmHVSJOHUIFTZTUFNVTJOHELDES Configuration Tool software. t5IFTZTUFNNVTUQSPNQUGPSVTFSTFF10. USER PASSWORDS) and administrator passwords when configuring the system by EKB2, EKB3, EKB3W keypad. For complete list of EN50131-1 Grade 3 standard requirements and how to enable/disable the associated features, please refer to 34. EN 50131-1 GRADE 2. 28 EN MANUAL ELDES ESIM364 V1.3