Download Owners Manual - Homeward Bath

Transcript
OPERATION & INSTRUCTION MANUAL
(3kW – 12kW Steam Generator & Control Panel)
REV 5/2012
Table of Contents
Part 1: Steam Generator
Safety Warnings
…………………………………………………………………
Safety Warnings in French …………………………………………………………
Users Instructions ………………………………………………………………….
Choosing a proper location
………………………………………….…….
Steam equipment installation diagram ……………………………………….
Installation of the pipeline ………………………………………………………..
Steam Generator blueprint
………………………………………………..
Electric requirements
………………………………………………………...
Power line assemble illustration …………………………………………………
Wiring Diagram 380-415V (3PH) …………………………………………………
Wiring Diagram 208V (3PH)
………………………………………………..
Wiring Diagram 220-240V (1PH/2PH) …………….………………………….
Installation of the top light …………………………………………………………..
Choose your type of machine
………………………………………………….
Steam generator configuration ……….…………………………………………
Troubleshooting guide
…………………..………………………………………
Specification …………………………………………………………………………..
2
3
4
4
5
5
8
10
11
12
13
14
15
16
17
18
19
Part 2: Control Panel
Control Panel blueprint
……..…………………………………………...………
Controller Installation instruction
……………………………………..……
Temperature detector installation…………………………………………..………
Controller Panel Illustration
……………………………………………………
Operating instructions
……………………………………………………….……
20
21
22
22
23
***SAVE THESE INSTRUCTIONS!
READ AND FOLLOW ALL INSTRUCTIONS.
***Ces instructions sont à conserver soigneusement!
ETUDIER ET ENSUITE SE CONFORMER À TOUTES
LES INSTRUCTIONS
REV 5/2012
WARNING!
To reduce the risk of injury, do not permit children to use this product unless they are
closely supervised at all times.
WARNING!
To reduce the risk of injury:
a. The wet surfaces of steam enclosures may be slippery. Use care when entering or
leaving.
b. The steam head is hot. Do not touch the steam head and avoid the steam near the
steam head.
c. Prolonged use of the steam system can raise excessively the internal human body
temperature and impair the body’s ability to regulate its internal temperature
(hyperthermia).
WARNING!
Hyperthermia occurs when the internal temperature of the body reaches a level several
degrees above the normal body temperature of 98.6° F. The symptoms of hyperthermia
include an increase in the internal temperature of the body, dizziness, lethargy,
drowsiness, and fainting. The effects of hyperthermia include:
a) Failure to perceive heat;
b) Failure to recognize the need to exit the steam bath;
c) Unawareness of impending risk;
d) Fetal damage in pregnant women;
e) Physical inability to exit the steam bath; and
f) Unconsciousness.
WARNING!
The use of alcohol, drugs, or medication can greatly increase the risk of hyperthermia.
Limit your use of steam to 10 – 15 minutes until you are certain of your body’s reaction.
Excessive temperatures have a high potential for causing fetal damage during the early
months of pregnancy. Pregnant or possibly pregnant women should consult a physician
regarding correct exposure.
Caution: Do not place wire in close proximity to hot water or steam pipes.
Attention: If the installation and operation instruction are not read or understood, do not
install. Install the controller based on the installation instruction.
If the controller is installed outside the steam room, the temperature sensor must be
installed in the steam room. To prevent overheating, operate the controller as described
in this manual only.
**Not for Space Heating Purposes
REV 5/2012
DANGER!
Afin de réduire les risque de blessures, ne jamais autoriser des enfants à utiliser ce appariel, sauf
s’ils sont étroitement surveillés, à tout moment
DANGER!
a) Les cabines où de la vapeur est introduite peuvent comporter des surfaces humides et donc
glissantes. La plus grande prudence est de rigueur au moment où l’utilisateur pénêtre, ou quitte la
cabine
b) La tête d’injection de la vapeur est à haute temperature; il faut veiller à ne pas entrer en contact
avec cette tête d’injection. De plus, il faudra éviter le contact avec le jet de vapeur à proximité de la
tête d’injection.
c) Soumis, d’une maniére prolongée aux températures occasionnées par un jet de vapeur, la
température interne du corps humain est susceptible de dépasser le seuil où celui-ci s’auto-régule,
provoquant l’hyperthermie.
DANGER!
a)
b)
c)
d)
e)
f)
Le corps humain enter en hyperthermie quand sa température interne dépasse de plusieurs degrés
sa temperature normale de 98.6º Fahrenheit, soit 37°Celsius.
La personne en état d’ hyperthermie souffre d’étourdissements, est léthargique, assoupie et
susceptible d’évanouissement.
Les effets de l’hyperthermie comportent:
Insensibilation à la chaleur
L’absence de volonté de quitter le local sous temperature élevée
Inconscience du danger imminent
En ce qui concerne les femmes enceintes, la possibilté de réactions nocives au niveau du fétus. Les
femmes enceintes, ou potentiellement enceintes, doivent préalablement consulter un médecin
Engourdissement physique menant à l’incapacité de quitter le local
Perte de connaissance
DANGER!
L’usage de drogues, d’alcool, de médicamments est susceptible d’augmentrer les risques
d’hyperthermie dans de larges proportions.
Avant utilization, il y a lieu de limiter votre usage de la vapeur à 10-15 minutes pour tester les
réactions de votre corps.
Pendant les premiers mois de grosses, des températures excessives sont susceptibles d'engendrer
des dommages, à issue fatale, au fétus. Les personnes enceintes, ou probablement enceintes,
doivent obtenir un avis médical en ce qui concerne les conditions auxquelles elles peuvent se
soumettre.
Avertissements




Ne pas installer de fils à proximité d’eau chaude ou de conduits de vapeur
La tête d’injection de vapeur ainsi que l’orifice de débit de vapeur sont à hautes températures –
Eviter le contact de ces appareils sous peine de brulûres.
Cet appareil ne doit pas être utilisé à de fins de chauffage ambiant
Avant toutes opérations de maintenance et de nettoyage, déconnecter la source de courant
Installation

Installer la tête d’injection de vapeur enter 15 et 30 cm au-dessus du sol. Si le bain de vapeur se
trouve dans la baignoire ou la salle de bains, installer la tête d’injection de vapeur à 15 cm audessus de la baignoire
Le jet de vapeur doit être dirigé vers le bas. Entourer le filet du tuyau de vapeur de quelques
couches de Teflon, visser la tête d’injection de vapeur et visser manuellement.
REV 5/2012
Part 1: Steam Generator
User instructions
Attention: We are not responsible for the malfunction and damage from improper installation that does
not comply with the user’s manual.
1. Make sure the model and the accessories are correct, including the voltage input.
2. Make sure the steam power is matched with the dimensions of the sauna room. Pay attention to
the steam room's cubic feet measurements and construction materials. If you have any
problems, please refer to the Page 11 to get the correct information.
3. Make sure to read this manual carefully for correct and effective use.
4. We shall not be responsible for the product damage or malfunction caused by self-installation or
the operation procedures which is not in compliance with the Operation and Instruction Manual.
5.
Please check the contents when the package arrives to assure it is in good condition. If you find
any damage in the package, please contact the transportation company or the supplier to claim
any damage.
6. This product must be used indoors.
Choosing proper location
Recommended locations for proper installation:
1. The steam box should not be located further than 16 feet away from the steam room.
2. The steam generator should not be installed in the steam room.
3. The steam generator should not installed outdoor or in any places that will influence the security
of the machine.
4. Do not install it in any places where the water might freeze.
5. Do not install near flammable objects or chemicals (coal, gas, etc.)
6. The steam generator should be installed in a dry and ventilated place.
7. Make sure the steam generator is secured on the wall and is in horizontally positioned.
8. On the other three sides, there has to be minimum of 12inces of space left between steam
generator and any other object.
9. The place where the machine is installed must be accessible for cleaning and possible service
work.
10. The steam generator should be in a close proximity to a drain for convenient Water Drain Valve
hook-up.
11. After use, the steam pipe, safety valve, drain valve, water pipe, steam outlet is still very hot.
12. Place steam outlet away from bathers.
Attention: install an exhaust fan outside of the steam room so that it can expel any excess steam for
proper ventilation.
REV 5/2012
Attention: The steam generator (including the controller) are UL approved.
Installation drawing of the steam generator
!
A tten tion : T h e d r a w i n g is o n ly
fo r ex pla n a tio n .
F or p r ac tic a l de s ig n o f s te am
r o o m ,
p le a s e
qu al ifie d
C o n tr o l p an el
c o n su lt
d e s ig n e r,
w ith
ar c h i te ct
o r b u il d e r.
S u p p ly
S te a m
o u tle t
p ip e
P r e s s u r e r e lie f v a lv e
W a te r I n le t P ip e
S te a m g e n e r a to r
W a te r D r a in Va lv e
S team O u tlet
Installation of pipeline
Attention: The installation of all the pipes should be completed by qualified plumbers or technicians.
1. Use brass or copper pipes only.
2. Do not use black, galvanized or PVC pipes.
Water supply pipe (1/2'')
1. Connect cold water pipe to water inlet.
2. Install shutoff valve in the water supply pipe. The shutoff valve should be installed in a place
where it is easily operated in case of emergency.
3. Clean the water supply pipe completely before connecting it to the steam engine.
4. It is suggested that a water filter should be installed in the water supply pipe.
5. The water pressure should be no less than 20 pounds/square inch (psi), and no more than 75
(psi). If necessary, decrease or increase the pressure accordingly.
REV 5/2012
Steam pipe (3kW/4.5kW pipe size: 1/2''£6kw & above:3/4'')
1. Do not install any valves in the steam pipes. The steam can never be obstructed.
2. Install a brass or copper steam pipe(3kW/4.5kW pipe size: 1/2''£6kw & above:3/4'') as connector
between the steam outlet and the steam nozzle.
3. The heat insulation material used to insulate the steam pipe should be resistant to temperature
as high as 248oF or higher.
4. Do not bend the pipe so that the cooled water will not stay in the curve of the steam pipe.
5. The shorter the steam pipe, the better. Try to decrease the number of elbows and avoid abrupt
turns.
6. Have no valleys or dips in the output steam line.
7. Do not install a valve in the steam line.
8. Do not connect the drain valve into the steam line.
9. Do not connect the over-pressure device output into the steam line.
Steam nozzle (3kW/4.5kW pipe size: 1/2''£6kw & above:3/4'')
WARNING!
The steam nozzle and steam outlet are very hot! Avoid installing the steam
nozzle near steam bathers.
1. Install the steam nozzle 6-12 inches above the ground. If the steam bath
is in the bathtub or bathroom, install the steam nozzle 6 inches above
the bathtub.
2. The steam spray outlet should be installed face down. Wrap a few circles
Teflon tape around the threads of the steam pipe, install the steam
nozzle and tighten with hands.
DANGER!
1. Installer la tête d’injection de vapeur enter 15 et 30 cm au-dessus du
sol. Si le bain de vapeur se trouve dans la baignoire ou la salle de bains,
installer la tête d’injection de vapeur à 15 cm au-dessus de la baignoire
2. Le jet de vapeur doit être dirigé vers le bas. Entourer le filet du tuyau de
vapeur de quelques couches de Teflon, visser la tête d’injection de
vapeur et visser manuellement
Attention: In order to protect the steam nozzle, do not use any tools to tighten that will scratch finish, use
a little soap water and soft sponge to wipe, and do not use erosive chemical solutions or abrasive cleaning
tools.
REV 5/2012
Attention:
Please consult your distributors of building materials like acrylic, fiber glass or other heat resistant
sheet about the installation and position of steam nozzle. It is suggested that MS-103412 heat
resistant material is used.
If
A i rp ro o f g re e n m a t e ri a l b e l t
non-heat-resistant
a c ry l i c
is
re se rv e
a
used
gap
as
no
m aterial
building
sm aller
like
m a t e ri a l ,
than
1 / 4 ''
a n d fi l l w i t h h e a t -i n su l a t e d m a t e ri a l .
U se
a irproof
silic on
c o r r e s p o n d i n g
m a t e ri a l
to
fi l l
the
to
achieve
w all
in
ge l
or
a i r p r o o f
the
the
gaps
in
w a t e r-
In si d e w a l l o f t h e st e a m ro o m
p ro o f a n d d a m p -p ro o f e ffe c t .
Drainpipe (1/2'')
According to national and local codes, the steam engine drain valve should be equipped with drainpipe.
The steam engine will drain water on its own.
Attention: drainpipe should not incline upwards.
Safety valve
1. Safety valve is to prevent too much steam pressure in the interior steam engine.
2. The pressure limit range of safety valve is 15PSI and the pressure will begin to decrease if
pressure should come over this value.
3. Provide the safety valve with exterior drainpipe.
Attention:
1. For safety, do not dismantle the pressure decrease valve at random.
2. To maintain the proper and automatic operation of safety valve, make sure the safety valve
connection pipe is smooth.
REV 5/2012
Blueprint for the steam engine
395mm
304mm
142mm
43mm
266mm
32mm
Water inlet
151m m
188mm
206mm
Safety valve
302mm
Steam outlet
Water
drainage
72mm
Fuse for wire power supply
Con troller wire
and light wire hole
Power wire hole
Fuse for wire
power supply
Steam outlet
370mm
Safety
valve
180mm
260mm
Water i nl et
Water drainage
400mm
100mm
160mm
Fuse for w ire power supply
C on t rol l er w i re
a nd li ght w ir e
hole
Power wi re hole
Fuse for wire
power supply
REV 5/2012
535mm
435mm
234mm
Steam o utlet
34mm
273mm
183mm
Water inlet
350mm
385mm
Safety valve
Water
drainag e
Fuse for wire power supply
Con troller wire
an d light wire hole
Po wer wire hole
Fuse for wire
power supply
Attention: Keep the steam engine clean.
Attention: To avoid damage to the equipment, do not connect strong electrical current directly to the
components.
IMPORTANT: Each unit shall be provided with a pressure-release device to address overpressure due to
inadvertent blockage of the output steam head or piping. If factory installed, it shall be provided with no
more than 6 inches (150mm) of piping between the device and the generator tank. If shipped with the
steam generator, the installation instructions shall indicate it shall be installed to the generator tank
with no more than 6 inches (150 mm) of piping.
REV 5/2012
Electrical requirements:
Electricity supply circuitry:
1. Test the voltage of the electric supply and make sure that the steam engine with suitable electric
voltage is used.
2. Insulated copper wire should be used with a heat resistant temperature of 194oF and a specified
voltage of 500V. Refer to national or local electricity consumption code for the specifications.
Refer to the ammeter for the ampere.
3. Choose steam engine with suitable item number, and plug the ground wire into the ground
terminal.
4. Install an independent GFCI circuit breaker between the power supply and the steam engine so
as to provide an electric supply with overflow protection and electricity leakage protection.
Important: All the connections must be in accordance with national and local electricity code and be
installed by professional electricians.
Ampere Meter
Applicable space
of the room (m3)
Electricity supply
Max. Electrical
current (A)
GS08-3kW
3~6
220-240V / (1PH/2PH)
13.7A
12# or 2.0mm2
GS08-4.5kW
4~7
220-240V / (1PH/2PH)
20.5A
12# or 4.0mm2
220-240V / (1PH/2PH)
27.3A
10# or 6.0mm2
208V / (3PH)
16.7A
12# or 4.0mm2
9A
12# or 2.0mm2
Type
GS08-6kW
5~8
380-415V / (3PH)
GS08-7.5kW
7~9
220-240V / (1PH/2PH)
34A
8# or 6.0mm2
208V / (3PH)
21A
10# or 4.0mm2
11.4A
12# or 2.0mm2
380-415V / (3PH)
GS08-9kW
10~12
220-240V / (1PH/2PH)
41A
8# or 8.0mm2
208V / (3PH)
25A
12# or 4.0mm2
13.7A
12# or 2.0mm2
380-415V / (3PH)
GS08-10.5kW
GS08-12kW
12~14
14~16
Specifications for
power wire ( A W G)
220-240V / (1PH/2PH)
48A
8# or 8.0mm2
208V / (3PH)
29A
8# or 6.0mm2
380-415V / (3PH)
16A
12# or 4.0mm2
220-240V / (1PH/2PH)
55A
6# or 10.0mm2
208V / (3PH)
33.3A
8# or 6.0mm2
380-415V / (3PH)
18.2A
12# or 4.0mm2
The data provided above are for 220-240V (1PH/2PH) and 208V (3PH) and 380-415V (3PH).
REV 5/2012
Assembly graph for power wire
Attention: To avoid the damage to the equipment, do not connect strong electric current to the component
directly.
WARNING!
This graph is for explanation only. For actual installation, refer to national and local electric codes and
consult with a professional electrician.
Power connection terminal
(3-12k W)
(6-18k W)
(220-240V~ 2PH)
(208V ~ 3PH)
Power connection terminal
(3-12k W)
(220-240V~ 1PH)
Power connection terminal
(6-9kW)
(380-415V~ 3PH)
(10.5-18kW)
(380-415V~ 3PH)
REV 5/2012
Wiring Diagram 380-415V (3PH)
S u p p ly
N
W a te r L e v e l S e n so r
L3
L2
L1
G
T o C o n t ro l P a n a l
R e d ( S h o r t P in )
B la c k ( L o n g P in )
T e rm i n a l B l o c k
Re d J1-2 Red
Red
Re d J2-2 Red
J2
Black
R ed
R e d
B ro w n
R e d
B la c k
Red
B lue
L ig h t
Red
B la c k
Re d
Drain water valve
Ye llow
S
Red
Red
Fill water valve
Red
S
Y e l l o w / G re e n
Black J1-1 Black
B lack
Red J2-1
P in )
J1
Ye llo w ( M id d le
Red
G S 08-6kW /7.5kW /9kW (380-415V ~ 3P H )
S u p p ly
N
L3
L2
L1
G
W a te r L e v e l S e n so r
T o C o n t ro l P a n a l
R e d ( S h o r t P in )
T e rm i n a l B l o c k
B la c k ( L o n g P in )
Ye llo w ( M id d le
P in )
Red J1-2 Red
J2
Black
R ed
Red J2-2 Red
R e d
Red
Drain water valve
Yellow
S
R e d
Red J2-1
Fill water valve
S
Black J1-1 Black
J1
Y e l l o w / G re e n
B lack
R e d
Red
B ro w n
B la c k
Red
R e d
Red
B lue
L ig h t
Red
B la c k
R e d
G S 0 8 - 1 0 .5 k W / 1 2 k W / 1 3 . 5 k W ( 3 8 0 - 4 1 5 V ~ 3 P H )
S u p p ly
W a te r L e v e l S e n so r
T o C o n t ro l P a n a l
R e d ( S h o r t P in )
N L3 L2 L1
G
T e rm i n a l B l o c k
B la c k ( L o n g P in )
Y e l l o w / G re e n
J1-2
J2-1
J2-2
J3-1
J3-2
J2
J3
B la c k
B lue
R e d
B ro w n
R e d
L ig h t
Red Red
S
R ed
B lack
Red
Drain water valve
S
R e d
Red
Fill water valve
R e d
Yellow
B lack
J1-1
P in )
J1
Ye llo w ( M id d le
R e d
B la c k
G S 08-15kW /18kW (380-415V ~ 3P H )
REV 5/2012
Wiring Diagram 208V (3PH)
S u p p ly
W a te r L e v e l S e n so r
L3 L2
T o C o n t ro l P a n a l
L1
G
R e d ( S h o r t P in )
T e rm i n a l B l o c k
Ye llo w ( M id d le
J1
B la c k ( L o n g P in )
P in )
Y e l l o w / G re e n
Drain water valve
Yellow
B lack
S
J3-2
J2-1
J3-1
J1-2
J1-1
J2-2
R ed
B lack
S
Red
B la c k
Red
R e d
Red
R e d
L ig h t
Red
B la c k
B lue
B ro w n
J2
R e d
J3
Fill water valve
R e d
R e d
G S 08-15kW /18kW (208V ~ 3P H )
S u p p ly
L3
W a te r L e v e l S e n so r
L2
L1
G
T o C o n t ro l P a n a l
R e d ( S h o r t P in )
T e rm i n a l B l o c k
B la c k ( L o n g P in )
Ye llo w ( M id d le
P in )
Red J1-1 Red
Red J1-2 Red
J2
B lack
B lue
R e d
B ro w n
R e d
L ig h t
Red
B la c k
B la c k
Red
S
R ed
Red
Drain water valve
Yellow
S
Red
Red
Fill water valve
Red
Re d J2-1 Red
J1
Y e l l o w / G re e n
B lack
Red
G S 08-6 k W /9 k W ( 2 0 8V ~ 3P H )
S u p p ly
L3
W a te r L e v e l S e n so r
L2
L1
T o C o n t ro l P a n a l
R e d ( S h o r t P in )
P in )
Red J3-1 Re d
Red J2-1 Red
Red J1-2 Red
B lack
R ed
Red J1-1 Red
J1
Red
Red J2-2 Red
S
Red
Red J3-2 Red
Drain water valve
Yellow
S
Y e l l o w / G re e n
J2
Fill water valve
B lack
J3
Ye llo w ( M id d le
G
T e rm i n a l B l o c k
B la c k ( L o n g P in )
R e d
R ed
B ro w n
Red
R e d
Red
B lue
L ig h t
Re d
B la c k
B la c k
Red
G S 0 8 - 1 0 . 5 k W / 1 2 k W / 1 3 .5 k W ( 2 0 8 V ~ 3 P H )
REV 5/2012
Wiring Diagram 220-240V (1PH/2PH)
S u p p ly
L2
N
W a te r L e v e l S e n so r
Ye llo w ( M id d le
L1
L
G
T o C o n t ro l P a n a l
R e d ( S h o r t P in )
B la c k ( L o n g P in )
T e rm i n a l B l o c k
P in )
Y e l l o w / G re e n
J1
Black
B lue
R e d
B ro w n
R e d
L ig h t
Red
B la c k
B la c k
Red
S
R ed
Red
Drain water valve
Yellow
S
R e d
Red
Fill water valve
R e d
J1-2 Red
J1-1 Black
B lack
R e d
G S08-3kW (220-240V ~
1P H /2P H )
S u p p ly
L2
N
W a te r L e v e l S e n so r
L1
L
G
T o C o n t ro l P a n a l
R e d ( S h o r t P in )
T e rm i n a l B l o c k
B la c k ( L o n g P in )
Ye llo w ( M id d le
P in )
Y e l l o w / G re e n
S
R e d
J1
R e d
B lack
R ed
J1-2 Red
Drain water valve
Yellow
S
J1-1 Black
Fill water valve
B lack
R e d
Red
B ro w n
B la c k
Red
R e d
Red
B lue
L ig h t
Red
B la c k
R e d
G S08-4.5kW (220-240V ~
1P H /2P H )
S u p p ly
L2
N
W a te r L e v e l S e n so r
L1
L
G
T o C o n t ro l P a n a l
R e d ( S h o r t P in )
B la c k ( L o n g P in )
T e rm i n a l B l o c k
Re d J1-1 R ed
Re d J1-2 Red
J2
B lack
B lue
R e d
B ro w n
R e d
L ig h t
Red
B la c k
Red
S
R ed
Re d
Drain water valve
Ye llow
S
Red
Red
Fill water valve
Red
Y e l l o w / G re e n
Black
Black J2-1 Black
B lack
Black J2-2
P in )
J1
Ye llo w ( M id d le
G S 08-6kW /7.5kW /9kW (220-240V ~
B la c k
Red
1P H /2P H )
REV 5/2012
S u p p ly
L2
N
L1
L
G
W a te r L e v e l S e n so r
T o C o n t ro l P a n a l
R e d ( S h o r t P in )
B la c k ( L o n g P in )
T e rm i n a l B l o c k
P in )
R e d
Red
B ro w n
Red J1-2 Red
Red J2-2 Red
Red J3-2 Red
B la c k
Red
R e d
Red
B lue
L ig h t
Red
B la c k
Black J3-1 Black
B lack
R ed
Black J2-1 Black
S
R e d
Black J1-1 Black
Drain water valve
Yellow
S
R e d
Y e l l o w / G re e n
J2 J1
Fill water valve
B lack
J3
Ye llo w ( M id d le
R e d
G S 0 8 - 1 0 .5 k W / 1 2 k W ( 2 2 0 - 2 4 0 V ~
1P H /2P H )
Installation of the top light
Attention: 12V output port is available for 12V light (not included).
If the light output is 12V, the power of the light should not be more than 35W.
The light should be installed on the top of the steam room.
Attention: Do not let the electrical components be exposed to moisture; otherwise, it may cause damage
or short circuit.
L ig h t
T h e s t e a m c o n t ro l p a n e l
( P o s s ib le lo c a tio n )
T h e s te a m
o u tle t
T h e s p a r e p la c e
u n d e r th e w a s h p a n
£ p o s s ib le lo c a tio n £
T h e s te a m
g e n e r a to r
Caution: The illustration is just for explanation, the practical installation must comply with the
national electric code, and installed by professional electrician.
REV 5/2012
Choose your type of machine
Measure the length, width and height (foot) of the current steam shower or bathtub room.
Example;
L:7 x W:5 x H:8 = 280 Cubic Feet
You would need Model s-900(it is that simple)
However, if your shower materials are;
A: Natural Stone (Granite or Marble etc.)
ADD
100%
B: Exterior walls
ADD
25%
C: Ceiling Heights exceeding 8 FT.
ADD
25%
D: Ceramic tile
ADD
50%
E: Glass (2 walls)
ADD
50%
Important: The calculation formula for selecting the type of steam engine is for reference only. Due to
the variability of the building, the specifications and size illustration are used as guidelines only. If you
have complete information, including actual blueprint, project instruction and building details, you can
select the type of steam unit required. Otherwise, the manufacturer will not be responsible for the
selection of the type of steam unit.
Maintenance of the steam engine
Important: Perform water discharge operation after each use.
1. Wait for the completion of automatic water discharge after each time of using the steam engine to
make sure the water in the tank is discharged completely before cutting off power supply.
2. There should not be any leakage or damage among the steam engine, steam nozzle, components
and pipes. They should be checked monthly.
3. Clean the water supply pipes of the steam engine once a year.
4. Check all the connections, faucets and connection terminal to see whether they become loose or
are damaged due to overheating.
5. Check the furring/scaling accumulated in the water tank and electric heating tube. If the furring
is thick, clean it (use diluted lemon acid to soak for 15-30 minutes).
6. Remove the water level sensory needle four times per year to clean the furring/scaling in the
needle.
REV 5/2012
Steam Generator Configuration
2
1
3
4
5
6
7
8
9
1 Enclosure
7 Water drain valve
Terminal block
2 Insulation bracket
8 Subsidiary water tank
Fuse
3 Circuit board
9 Main water tank
Ground connector
4 Steam Outlet
Heating Element
5 Pressure relief valve
221 F Hi-limit
Water level sensor
6 Water fill valve
Transformer
221 O F Hi-limit
O
Relay
REV 5/2012
Trouble shooting:
Trouble
Causes of Trouble
1.
2.
Trouble-Shooting Method
The machine does not start when
power is supplied
The fuse is burned.
The wire connection
terminal is loose.
3.
Bad Contact in the
connection wire between the
controller and the steam
engine.
1. Change the fuse (on the
shell 0.8A/250V)
2. Plug-in the wire
connection terminal
3. Make sure the steam
engine and the controller
is in good contact.
GFCI switch breaks automatically
1. The wire connector is damp or
damaged.
2. The heating tube breaks
1. Check whether the wire
connector is damp or
damaged, and dry with
dryer if dampened.
2. Change the heating tube.
When the machine is started, hot
water comes out with little or no
steam
1.
The water drainage valve is
broken.
The display screen on the control
panel does not display
1. The power wire is not
connected properly. The
connection plug between the
control panel and the
electrically-controlled box is
loose.
2. Trouble with plug board.
Water leakage
1. The water pipe connector is
loose or the pipe breaks.
2. Water leakage in the water
input valve or the water
drainage valve
No steam when starting the
machine
1.
2.
3.
4.
The steam does not come out, there
are water sounds in the machine
1. The steam pipe is jammed.
The light can not be turned on
The display box displays normally,
but with no steam input
1.
2.
3.
4.
No electricity
No water
The set temperature is too low
Trouble with wire
The fuse is burned.
The light is broken.
The wire is broken.
The plug does not have good
contact
1. Too much pressure inside the
steam engine, so the system
breaks for heat protection.
2. The heat protection wire is
broken.
1. Change the water drainage
valve.
1. Tighten the loose
connector, and change the
broken pipe.
2. Change the water input
valve or the water
drainage valve.
1.
Tighten the loose
connector, and change the
broken pipe.
2.
Change the water
input valve or the water
drainage valve.
1. Check the power supply
2. Check the water input
pipe and water input valve
3. Reset the temperature
4. Contact the distributor
1. Cut power supply to check
whether the steam pipe is
smooth.
1. Change the fuse (on the
shell 1A/250V)
2. Change the light bulb.
3. Change wire.
4. Replace plug
1. Check the team transport
pipe and restore
automatically after heat
protection becomes cool.
2. Check the heat protection
wire to make sure the
connection is good.
REV 5/2012
Specifications
Important: The list below is for reference only. In actual checking and repairing, based on the national
and local codes, ask professional service personnel for advice.
Power Output
3kW
4.5kW
6kW
7.5kW
9kW
10.5kW
12kW
15kW
18kW
Potency Error
±10%
±10%
±10%
±10%
±10%
±10%
±10%
±10%
±10%
Duration
>1500V
>1500V
>1500V
>1500V
>1500V
>1500V
>1500V
>1500V
>1500V
Resistance
>20W
>20W
>20W
>20W
>20W
>20W
>20W
>20W
>20W
Steam Pressure
0.12MPa
0.12MPa
0.14MPa
0.14MPa
0.14MPa
0.16MPa
0.16MPa
0.16MPa
0.16MPa
Steam Volume
Steam
Production Time
Water Tank
Volume
140
160
180
220
260
300
360
450
500
100-150
90-120
100-160
90-140
80-130
180-240
150-160
120-150
90-150
2.5L
2.5L
5.7L
5.7L
5.7L
12L
12L
12L
12L
3~6
4~7
5~8
7~9
10~12
12~14
14~16
18~20
20~24
Applicable space
of the room (m3)
Important: The parameter listed in the above table may vary from place and temperature, please
consult a qualified designer or architect for more detailed use.
NOTE: Steam Bath Generators are considered to be able to cooperate above atmospheric pressure in
abnormal operation and shall therefore comply with UL clause 64.8.
REV 5/2012
Part 2: Control Panel
Attention: Before installing the controller, make sure the steam generator is shut off otherwise damage
may occur.
Do not use a controller inconsistent with the steam generator, do not use the controller to operate steam
generator of other brand.
The instructions include important safety, operation and maintenance information.
Keep the instruction manual handy.
If the steam generator is damaged or does not operate normally, do not continue to install or use.
Control Panel Blueprint
( mm)
a
REV 5/2012
Controller Installation instruction
Attention: Before installing the controller, make sure the steam engine is shut off.
Step one
Determine the installation location of the controller.
For installation:
1.
4 -5feet away from the ground.
2.
Locate controller on separate wall from steam
nozzle.
3.
Do not expose yourself to the direct spray of
steam.
The controller wire is 1.5 feet long with a controller
lengthened wire of 19.5 feet long. In the installation of
controller should be in a position not more than 21 feet
from the steam engine. If longer wire is needed contact professional
service personnel.
Attention: Do not install the controller under the water pipe or in a
position where water can easily make contact.
Step two
Drill a round hole of 35mm in diameter in a chosen position.
Step three
Pull the controller wire through the round hole, connect it to the
corresponding wire in the engine.
Attention: Do not over tighten or clip the controller wire.
Step four
Start the power supply of steam engine, check and adjust
connection, check each item on the 6th page to make sure all
functions work properly.
Attention: Before setting the controller,
make sure the steam engine is shut off.
Step five
Remove the paper at the bottom.
To achieve good adhesion, make sure surface is clean and dry.
Step six
Locate the display screen at the 12 o'clock position, and press tight.
Adhere controller to the wall.
Attention: Level controller.
IMPORTANT: PLEASE place sticker that comes with unit in a visible
location to pass inspection.
REV 5/2012
Temperature detector installation
1. The position of the temperature sensor should be within 4-5ft above the ground. Try to avoid
installing near the steam mouth or the opening side of the steam room door.
2. As shown in Fig.1, drill a small hole (10mm) in the selected position.
3. Apply silicone along the edge of the back of the detector foundation (as shown in Fig.2).
4. Use a locknut to lock the detector foundation. (As shown in Fig.2)
5. Push the temperature detector go through the back of the detector foundation (As shown in Fig.3)
6. The temperature detector should be installed by extending about 1cm from the front of the room for
accurate temperature.
7. Apply silicone to the back and set the detector. (As shown in Fig.3)
1cm
10
Temperature detector
foundation
Drill
(Fig.1)
Locknut for temperature
detector foundation
Ground
(Fig.2)
1.2~1.5m
(Fig.3)
Controller Panel illustration
1 Power ON/OFF
2 Steam Indicator LED
3
6 LED SCREEN
7
8
4
9 Power Indicator LED
5
Water drain Key
Mood Light ON/OFF
REV 5/2012
Operation Instruction:
1. When power supply is applied to the steam box system the RED stand-by light will be illuminated.
(see Illustration of the controller panel for location)
2. Pressing the ON/OFF button will start the system. The steam box will fill with water. This will take
a few minutes; the water may cycle on and off a few times as the water tank fills. This is normal
operation. The display will show ambient Temperature and Running time – 8hrs.
3. When the red light next to the ON/OFF button becomes illuminated the system is operating and will
start generating steam for 5 – 8 minutes.
4. Pressing the UP and Down arrows under the temperature display will adjust the temperature
accordingly. The temperature can be changed from Celsius to Fahrenheit . The temperature range is
25ºC to 68ºC or 78ºF to 150ºF. The unit will cycle on and off to maintain the set temperature.
Once the user has adjusted the temperature to their preferred temperature, the temperature lights will
blink several times and time will be the active temperature.
5. When system is on, press UP or DOWN triangle keys on control panel to adjust running time,
meanwhile, time display window shows the time you desire. The steam time range is 1minute to 8hours.
When setting time to less than 1hour, the time unit is by the minute; when more than 1hour, the unit is
hour and time display window will indicate h.
6. When system is on, press the LIGHT key to turn on light; press again to turn off.
7. When system is in waiting state, press keys DOWN temperature key and UP triangle at the same time
will switch Fahrenheit and centigrade and temp display window display/ F means Fahrenheit; display C
means centigrade. System will save it for next usage.
Attention:
1.
2.
Use soft cloth with soap and water to clean the controller.
Do not use abrasive cleaning tools.
REV 5/2012