Download FAG Motion Guard, CHAMPION.CONTROL

Transcript
16
BA 24
0013BD3
PLC
connection strip
Inputs
1
in
I1
Green LED
White cable
2
in
I2
Red LED
1
No green signal
inv
1
No red signal
inv
CHAMPION CONTROL IMPULSE
Black cable
3
in
l3
Power supply
CHAMPION CONTROL IMPULSE
Cable breakage
and
&
on delay
50 sec
on delay
120 sec
Schaeffler KG
Georg-Schäfer-Str. 21
97421 Schweinfurt
B01, B09 + B11 optional,
only necessary for storage
of error display
and
&
or
1
When using B02, I3
Malfunction display only if CHAMPION CONTROL IMPULSE is supplied with power
Q
latching relay
Reset
Set
1
GRÖSSE
MASSTAB
28.a
BLATT
ZEICHN.NR.
At/Za
Erstellt
08.01.2001
1 von 1
1.1
REV.
Connect out Q2 = high
with
- malfunction
- LC unit empty
- cable breakage
PLC
connection strip
Outputs
out
Logic scheme for evaluation of LED signals on FAG Motion Guard
CHAMPION CONTROL IMPULSE from version 3.1
Separate display of
normal function - malfunction/cable breakage - empty level of LC unit
and
&
FAG CHAMPION.CONTROL-IMPULSE
PLC programming suggestion with one output signal
Schaeffler Group Industrial