Download RKD Application Guide
Transcript
#2 THE “TWO-WIRE PATH” The “two-wire path” carries the power from the controller to the valves. This “two-wire path” is simply a two-conductor wire (Tucor #16/2) that all valves are connected to. Valves can be connected to the two-wire path in series like a string of ornamental lights. There is no polarity between the conductors in a two-wire system. Tucor Wire 120-Volt Power Wire Note: “Tucor Wire” is a double-insulated, two-conductor wire made by Paige Electric specifically for Tucor. Inside a high-density polyethylene jacket are red and black insulated conductors. These conductors are color-coded for ease of troubleshooting. #3 DECODERS A “decoder” is installed at each valve solenoid and connected to the two-wire path. The decoder acts as a switching device that turns a valve on/off with a signal from the controller. Blue wires to two-wire path White wires to valve solenoid Note: Solenoid wire 150 feet max. with #18 wire. RKLD-050 DECODER RKD Application Guide 2