Download Single-Slot PC Interface Module (PCIM) User`s Manual
Transcript
4 GetCir – Read Input Circuit Value Code Summary #include <pcim.h> int GetCir (IMnum, Devicenum, Offset, State) unsigned int IMnum, Devicenum; unsigned int Offset; char *State; Description A Get Circuit call allows the state of a single input circuit to be read from the specified PCIMs Input Table and be placed into the Host memory “State” parameter. IMnum is the PCIM number configured during initialization. The Devicenum parameter specifies the serial bus address of the device which contains the input circuit. The “Offset” parameter indicates which bit of Devicenum is to be read. This value ranges from 1 through 1024 (in bits). “State” is a character pointer in which GetCir will store the value of the circuit as indicated by the above parameters. The contents of State will be either a ‘1’ or ‘0’ (ON or OFF). Parameters are summarized as follows: Parameter Values IMnum Relative number of PCIM Devicenum 0–31 Specifies I/O device from which input circuit will be read Offset 1–1024 Input circuit offset in specified I/O device, in bits 0/1 ON or OFF condition of circuit read from PCIM State 4-38 1–64 Function Single-Slot PCIM User’s Manual – January 1994 GFK-0881