Download Operating principle of the control panel

Transcript
C 20
Operating principle of the control
panel
General
Control keys
If a key (sensing switch) is depressed when its function is
not available or it has no effect, a brief audio signal is
emitted.
■
The LED indicator is ON when the control
key is activated (ex.: Sniffer ON).
SNIFFER
The LED indicator is OFF when the control
key is deactivated (ex.: Sniffer OFF).
SNIFFER
AUTO CAL
SNIFFER
ZERO
GB 01361 - Edition 01 - December 01
ASM 182 TD+
CYCLE
AUTO CAL
MUTE
CYCLE
SNIFFER
ASM 192 T2D+
Alcatel Vacuum Technology France - ASM 182 TD+ - ASM 192 T2D+ User’s Manual
1/4
C 20
Operating principle of the control
panel
Menu selection
access keys
mbar.l/s
Pa.m3/s
F1
F2
LEAK RATE
F3
F4
10 -3 10 -2 10 -1
NEXT
SET POINTS
SPECTRO
+
1
10 -8
10 -9
10 1
10 2
INLET PRESSURE
RESET
MAINTENANCE
Torr.l/s
COR
10 -12 10 -11 10 -10
OTHER
AUTO CAL
SNIFFER
10 -7
10 -6
10 3 mbar
hPa
Torr
10 -5
STDBY
10 -4
10 -3
EVAC
10 -2
TEST
ZERO
CYCLE
SET POINTS
ASM 182 TD+
F1
10 -3
10 -2
10 -1
Pa
SPECTRO
10 -5
10 -4
10 -3
F2
MUTE
CYCLE
SNIFFER
MAINTENANCE
OTHER
Menu selection access keys
F3
F4
mbar
AUTO CAL
SPECTRO
NEXT
SET POINTS
SPECTRO
+
MAINTENANCE
RESET
OTHER
ASM 192 T2D+
Pressing the corresponding Menu selection
key a second time deactivates the menu.
The LED indicator is then turned OFF and
the previous screen is displayed again.
2/4
SET POINTS
SET POINTS
Alcatel Vacuum Technology France - ASM 182 TD+ - ASM 192 T2D+ User’s Manual
GB 01361 - Edition 01 - December 01
The LED indicator comes ON after
depressing the key. It activates the menu.
Then the corresponding menu is shown on
the alphanumeric display.
C 20
Operating principle of the control
panel
Parameter function keys
F1
There are up to four function keys available on the
alphanumeric display (F1, F2, F3 and F4). One
parameter key per line can be changed at a time.
F2
F3
F4
The LED indicator is ON when the
corresponding function key is available:
the modification of the parameter displayed
on the line is authorized.
F1
Press the function key: the LED indicator
will flash: the modifications changes can be F1
performed. It is possible to escape and reset
the previous value by pressing RESET key or the active
menu selection key.
Once the parameter is modified, pressing
the function key again validates it: the LED
indicator remains ON and stops flashing.
GB 01361 - Edition 01 - December 01
Description of each
access keys
NEXT
RESET
F1
Next menu or next step of a function,
Next PARAMETER DIGIT,
Displays the WARNING/ERROR message on the
LCD when an error is detected.
Resets original parameter value (before a new
parameter value is validated) and deactivates the
parameter key.
+
YES, or ON, or OPEN, or active, or increase value,
or increase audio volume, or select more sensitive
test mode.
-
NO, or OFF, or CLOSE, or deactive, or decrease
value, or decrease audio volume, or select less
sensitive test mode.
Alcatel Vacuum Technology France - ASM 182 TD+ - ASM 192 T2D+ User’s Manual
3/4
C 20
Operating principle of the control
panel
Values adjustment with
the control panel
Procedure
In many menus, some values can be adjusted (reject point,
password, timer, ...).
Please follow the procedure described below.
Press function key of the desired line (where
the value needs to be adjusted).
For each parameter, use
modification keys in order to adjust
the value and go to the next
parameter.
-
F1
+
NEXT
or
Repeat the same operation as needed.
F1
GB 01361 - Edition 01 - December 01
After the last modified parameter, press again
the function key to validate the changes.
4/4
Alcatel Vacuum Technology France - ASM 182 TD+ - ASM 192 T2D+ User’s Manual