Download Storm Strikemaster Manual
Transcript
2 ii) INSTALLATION INSTRUCTIONS Fixing Instructions (Please read carefully before attempting installation.) Rear Casing 1. Select a suitable location with a sound flat surface. Using the case as a template, mark the position of the four fixing holes (A) on the surface. 2. Drill and plug the fixing holes to suit fixing screws (E) as supplied. 3. Locate the anti-tamper switch actuator plate (F) on the rear face of the case in the position as shown. The fixing screws (E) may be positioned in the case to assist in the accurate location of the plate. 4. Locate the thicker (6mm) sealing gasket (B) on the rear face of the case before positioning the case over the fixing holes (A). (Be sure to run the cable through the hole in the gasket prior to securing the case.) 5. Secure the case to the surface using the fixing screws (E) as supplied. Keypad to Casing 6. When making the electrical connections to the connector block care should be taken not to damage the thin sealing gasket (C) fixed to the front face of the rear case. [For connection details see section iii) of this manual.] 7. Fix the keypad to the rear case using the thread forming security screws (D) as supplied. (Please ensure the nylon sealing washers are located beneath the head of the security screws (D). Please note a special bit is provided for tightening these screws. 8. Check the installation to ensure gaskets are in place and compressed evenly around the perimeter of the case. Note: On rough or uneven surfaces it may be necessary to apply a bead of silicone sealant around the inner face of the case at the point where it D meets the mounting surface. Where this method of sealing is necessary the thicker sealing gasket (B) must not be fitted. A F 1 2 B 3 4 5 6 7 E 8 9 0 C iii) ELECTRICAL AND DATA CONNECTIONS Door Sensor Remote/ Exit Switch 10. Remote Switch - To open door 1 from within secure area 9. Door Sensor - Used to monitor door 1 condition (open/closed) Door Strike 8. Door/Call Bell - Open collector gate 7. Alarm/Door 2 Release Relay - Fully floating (volts free contact) 6. Alarm/Door 2 Release Relay - Fully floating (volts free contact) 5. Door 1 Release Relay - Relay output (normally closed) 4. Common - Relay common Door/call Bell 3. Door 1 Release Relay - Relay output (normally open) 2. Supply - Range 11 to 28 volts dc or 9 to 20 volts ac. Alarm Bell/ Klaxon 1. Return - Zero volts Power Supply +V 0V Note: When making connection to the door strike, select ‘relay normally open’ or ‘relay normally closed’ to suit the intended application and locking mechanism. Note: To achieve maximum protection against EMC, RFI, or damage from Electro-static Discharge it is recommended that the keypad casing is earthed (grounded) via the screw terminal attached to the metal shield on the rear face of the keypad. This terminal is identified by a symbol. It is recommended that a regulated, fully isolated power supply is used to power the StrikeMaster keypad. (Keymat Technology part no. DEPS0101 or DEPS0201 or equivalent). Bifular wound supplies are not recommended. DES-MAN ISS.3