Download this file
Transcript
17 CONTROL COMMAND • Command table (continued) Command Sub command 0E B0 B1 D0 D3 Set as non-select channel Set as select channel Set scan resume OFF Set scan resume ON 0F 00 01 10 11 12 Turn the split function OFF Turn the split function ON Select simplex operation Select –DUP operation Select +DUP operation 00 AM/FM/WFM modes: Select 10 Hz tuning step SSB/CW/RTTY modes: TS OFF 01 02 03 04 05 06 07 08 09 Select 100 Hz tuning step Select 1 kHz tuning step Select 5 kHz tuning step Select 9 kHz tuning step Select 10 kHz tuning step Select 12.5 kHz tuning step Select 20 kHz tuning step Select 25 kHz tuning step Select 100 kHz tuning step 10 AM/FM/WFM modes: Select MHz step SSB/CW/RTTY modes: Invalid Select/read attenuator (0=OFF, 12=ON (12 dB)) 10 11 — 13 00 01 02 14 143 Description Command 14 Description 15 01 02 11 12 13 14 Read squelch condition Read S-meter level Read RF power meter Read SWR meter Read ALC meter Read COMP meter 16 02 Preamp (0=OFF; 1=ON) 12 AGC selection (1=Fast; 2=Mid; 3=Slow) Noise blanker (0=OFF; 1=ON) Noise reduction (0=OFF; 1=ON) Auto notch (0=OFF; 1=ON) Repeater tone (0=OFF; 1=ON) Tone squelch (0=OFF; 1=ON) Speech compressor (0=OFF; 1=ON) Monitor (0=OFF; 1=ON) VOX function (0=OFF; 1=ON) Break-in (0=OFF; 1=semi breakin; 2=full break-in) Manual notch (NF1) (0=OFF; 1=ON) DTCS (0=OFF; 1=ON) VSC (0=OFF; 1=ON) Twin Peak Filter (0=OFF; 1=ON) Dial lock function (0=OFF, 1=ON) Manual notch (NF2) (0=OFF, 1=ON) 22 40 41 42 43 44 45 46 47 Announce with voice synthesizer (00=all data; 01=frequency and S-meter level; 02=receive mode) 01 + Level data [AF] level setting (0=max. CCW to 255=max. CW) 02 + Level data [RF] level setting (0=max. CCW to 255=11 o’clock) 03 + Level data [SQL] level setting (0=11 o’clock to 255=max. CW) 06 + Level data NR level setting (0=min. to 255=max.) 07 + Level data Inside [PBT] setting or IF shift setting (0=max. CCW, 128=center, 255=max. CW) 08 + Level data Outside [PBT] setting (0=max. CCW, 128=center, 255=max. CW) 09 + Level data CW Pitch setting (0=300 Hz, 128=600 Hz, 255=900 Hz, in 5 Hz steps) 0A + Level data RF Power setting (0=mini. to 255=max.) 0B + Level data MIC Gain setting (0=mini. to 255=max.) 0C + Level data Key Speed setting (0=slow to 255=fast) 0D + Level data NOTCH (NF1) frequency setting (0=low freq. to 255=high freq.) 0E + Level data COMP Level setting (0=0 to 10=10) 0F + Level data Break-IN DELAY setting (20=2.0d to 130=13.0d) 12 + Level data NB level setting (0=0 to 255=100%) 15 + Level data Monitor gain setting (0=0 to 255=100%) 16 + Level data VOX gain setting (0=0 to 255=100%) Sub command 17 + Level data Anti-VOX gain setting (0=0 to 255=100%) 18 + Level data Contrast (LCD) setting (0=0 to 255=100%) 19 + Level data Bright (LCD) setting (0=0 to 255=100%) 1A + Level data NOTCH (NF2) frequency setting (0=low freq. to 255=high freq.) 48 4B 4C 4F 50 51 19 00 Read the transceiver ID 1A 00 Send/read memory contents (see p. 146 for details) Send/read band stacking register contents (see p. 146 for details) Send/read memory keyer contents (see p. 146 for details) Send/read the selected filter width (SSB, CW, RTTY: 0=50 Hz to 40/31=3600/2700 Hz; AM: 0=200 Hz to 49=10 kHz) Send/read the selected AGC time constant (0=OFF, 1=0.1/0.3 sec. to 13=6.0/8.0 sec.) RF Power setting (0=mini. to 255=max.) MIC Gain setting (0=mini. to 255=max.) Send/read of SSB TX bandwidth (lower edge) for wide (0=100, 1=200, 2=300, 3=500 HZ) Send/read of SSB TX bandwidth (higher edge) for wide (0=2500, 1=2700, 2=2800, 3=2900 HZ) Send/read of SSB TX bandwidth (lower edge) for middle (0=100, 1=200, 2=300, 3=500 HZ) Send/read of SSB TX bandwidth (higher edge) for middle (0=2500, 1=2700, 2=2800, 3=2900 HZ) 01 02 03 04 050001 050002 050003 050004 050005 050006