Download this file

Transcript
17
CONTROL COMMAND
• Command table (continued)
Command
Sub command
0E
B0
B1
D0
D3
Set as non-select channel
Set as select channel
Set scan resume OFF
Set scan resume ON
0F
00
01
10
11
12
Turn the split function OFF
Turn the split function ON
Select simplex operation
Select –DUP operation
Select +DUP operation
00
AM/FM/WFM modes:
Select 10 Hz tuning step
SSB/CW/RTTY modes: TS OFF
01
02
03
04
05
06
07
08
09
Select 100 Hz tuning step
Select 1 kHz tuning step
Select 5 kHz tuning step
Select 9 kHz tuning step
Select 10 kHz tuning step
Select 12.5 kHz tuning step
Select 20 kHz tuning step
Select 25 kHz tuning step
Select 100 kHz tuning step
10
AM/FM/WFM modes:
Select MHz step
SSB/CW/RTTY modes: Invalid
Select/read attenuator (0=OFF,
12=ON (12 dB))
10
11
—
13
00
01
02
14
143
Description
Command
14
Description
15
01
02
11
12
13
14
Read squelch condition
Read S-meter level
Read RF power meter
Read SWR meter
Read ALC meter
Read COMP meter
16
02
Preamp (0=OFF; 1=ON)
12
AGC selection
(1=Fast; 2=Mid; 3=Slow)
Noise blanker (0=OFF; 1=ON)
Noise reduction (0=OFF; 1=ON)
Auto notch (0=OFF; 1=ON)
Repeater tone (0=OFF; 1=ON)
Tone squelch (0=OFF; 1=ON)
Speech compressor (0=OFF; 1=ON)
Monitor (0=OFF; 1=ON)
VOX function (0=OFF; 1=ON)
Break-in (0=OFF; 1=semi breakin; 2=full break-in)
Manual notch (NF1) (0=OFF; 1=ON)
DTCS (0=OFF; 1=ON)
VSC (0=OFF; 1=ON)
Twin Peak Filter (0=OFF; 1=ON)
Dial lock function (0=OFF, 1=ON)
Manual notch (NF2) (0=OFF, 1=ON)
22
40
41
42
43
44
45
46
47
Announce with voice synthesizer
(00=all data; 01=frequency and
S-meter level; 02=receive mode)
01 + Level data [AF] level setting (0=max. CCW to
255=max. CW)
02 + Level data [RF] level setting (0=max. CCW to
255=11 o’clock)
03 + Level data [SQL] level setting (0=11 o’clock to
255=max. CW)
06 + Level data NR level setting (0=min. to
255=max.)
07 + Level data Inside [PBT] setting or IF shift
setting (0=max. CCW, 128=center, 255=max. CW)
08 + Level data Outside [PBT] setting
(0=max. CCW, 128=center,
255=max. CW)
09 + Level data CW Pitch setting (0=300 Hz,
128=600 Hz, 255=900 Hz, in 5 Hz
steps)
0A + Level data RF Power setting (0=mini. to
255=max.)
0B + Level data MIC Gain setting (0=mini. to
255=max.)
0C + Level data Key Speed setting (0=slow to
255=fast)
0D + Level data NOTCH (NF1) frequency setting
(0=low freq. to 255=high freq.)
0E + Level data COMP Level setting (0=0 to
10=10)
0F + Level data Break-IN DELAY setting (20=2.0d
to 130=13.0d)
12 + Level data NB level setting (0=0 to
255=100%)
15 + Level data Monitor gain setting (0=0 to
255=100%)
16 + Level data VOX gain setting (0=0 to
255=100%)
Sub command
17 + Level data Anti-VOX gain setting (0=0 to
255=100%)
18 + Level data Contrast (LCD) setting (0=0 to
255=100%)
19 + Level data Bright (LCD) setting (0=0 to
255=100%)
1A + Level data NOTCH (NF2) frequency setting
(0=low freq. to 255=high freq.)
48
4B
4C
4F
50
51
19
00
Read the transceiver ID
1A
00
Send/read memory contents (see
p. 146 for details)
Send/read band stacking register
contents (see p. 146 for details)
Send/read memory keyer contents
(see p. 146 for details)
Send/read the selected filter width
(SSB, CW, RTTY:
0=50 Hz to 40/31=3600/2700 Hz;
AM: 0=200 Hz to 49=10 kHz)
Send/read the selected AGC time
constant (0=OFF, 1=0.1/0.3 sec. to
13=6.0/8.0 sec.)
RF Power setting (0=mini. to
255=max.)
MIC Gain setting (0=mini. to
255=max.)
Send/read of SSB TX bandwidth
(lower edge) for wide
(0=100, 1=200, 2=300, 3=500 HZ)
Send/read of SSB TX bandwidth
(higher edge) for wide (0=2500,
1=2700, 2=2800, 3=2900 HZ)
Send/read of SSB TX bandwidth
(lower edge) for middle
(0=100, 1=200, 2=300, 3=500 HZ)
Send/read of SSB TX bandwidth
(higher edge) for middle (0=2500,
1=2700, 2=2800, 3=2900 HZ)
01
02
03
04
050001
050002
050003
050004
050005
050006