Download MX2 Users Manual
Transcript
ModBus Data Listing Section B-4 Register Function name No. 1411h Input [7] active state 1412h to (Reserved) 1414h 1415h Output [11] function Function code C017 – R/W – 0 (NO), 1 (NC) Inaccessible C021 R/W 1416h C022 R/W 1421h to (Reserved) 1423h – – 141Ah Alarm relay function C026 R/W 141Bh [EO] terminal selection C027 R/W 141Ch [AM] terminal selection C028 R/W – C030 – R/W 0 (RUN: running), 1 (FA1: constantspeed reached), 2 (FA2: set frequency overreached), 3 (OL: overload notice advance signal (1)), 4 (OD: output deviation for PID control), 5 (AL: alarm signal), 6 (FA3: set frequency reached), 7 (OTQ: over-torque), 9 (UV: undervoltage), 10 (TRQ: torque limited), 11 (RNT: operation time over), 12 (ONT: plug-in time over), 13 (THM: thermal alarm signal), 19 (BRK: brake release), 20 (BER: braking error), 21 (ZS: 0 Hz detection signal), 22 (DSE: speed deviation maximum), 23 (POK: positioning completed), 24 (FA4: set frequency overreached 2), 25 (FA5: set frequency reached 2), 26 (OL2: overload notice advance signal (2)), 31 (FBV: PID feedback comparison), 32 (NDc: communication line disconnection), 33 (LOG1: logical operation result 1), 34 (LOG2: logical operation result 2), 35 (LOG3: logical operation result 3), 39 (WAC: capacitor life warning), 40 (WAF: cooling-fan), 41 (FR: starting contact signal), 42 (OHF: heat sink overheat warning), 43 (LOC: low-current indication signal), 44 (M01: general-purpose output 1), 45 (M02: general-purpose output 2), 46 (M03: general-purpose output 3), 50 (IRDY: inverter ready), 51 (FWR: forward rotation), 52 (RVR: reverse rotation), 53 (MJA: major failur), 54 (WCO: window comparator O), 55 (WCO: window comparator OI), 58(FREF), 59(REF), 60(SETM), 0 (output frequency), 1 (output current), 2 (output torque), 3 (digital output frequency), 4 (output voltage), 5 (input power), 6 (electronic thermal overload), 7 (LAD frequency), 8 (digital current monitoring), 10 (heat sink temperature), 12 (general-purpose output YA0),15 ,16(option) 0 (output frequency), 1 (output current), 2 (output torque), 4 (output voltage), 5 (input power), 6 (electronic thermal overload), 7 (LAD frequency), 10 (heat sink temperature), 11 (output torque [signed value]), 13 (general-purpose output YA1),16(option) – 200 to 2000 C031 C032 – R/W R/W – 0 (NO), 1 (NC) 0 (NO), 1 (NC) – – – – C036 – C038 R/W – R/W 0 (NO), 1 (NC) – 0 (output during acceleration/deceleration and constant-speed operation), 1 (output only during constant-speed operation) – – – 141Dh 141Eh Output [12] function (reserved) Digital current monitor reference value 141Fh Output [11] active state 1420h Output [12] active state 1421h to (Reserved) 1423h 1424h Alarm relay active state 1425h (Reserved) 1426h Output mode of low current detection R/W Monitoring and setting items Data resolution – – – – – – – – – 0.1 [%] 297