Download Software user manual
Transcript
eNod4-T Ethernet Digital Process Transmitter Color State Green Meaning Blinking STANDBY: the device has not been configured Always on DEVICE OPERATIONAL: Device is operating correctly Blinking MINOR FAULT: the device detected a recoverable minor fault Always on MAJOR FAULT: the device detected a non-recoverable major fault Blinking Self-test on power up Always off Device not powered or defective Red Red/Green - State of the ACT / LINK ETH1 and ETH2 network RJ45 connector LED: Color State Meaning LINK (Eth1 & Eth2) Green Always on A physical connection to the Ethernet exist Always off Device not connected to the Ethernet ACT (Eth1 & Eth2) Yellow On The device sends/receives Ethernet frames Always off No traffic on the Ethernet 7.8. Data arrangement The provision model of data is very similar to the one used in PROFIBUS DP, this will allow users of eNod4 Profibus an easy recycling of their application. 7.8.1. Cyclic data (IO Data) Cyclic exchanged data are either provided by the IO-Device and consumed by the IO-Controller or provided by the IOController and consumed by the IO-Device. Data are contained in input or input/output modules (from the point of view of the IO-Controller). These modules are defined in the GSDML file and are presented in a separate chapter. The designer can select modules that he needs and place them in communication slots. Thus, the slots contain modules. Slots are numbered. Slot 0 is not usable for data exchange, it contains DAP (Device Access Point) informations which defines, among other, which data module can be contained in which slots. 7.8.2. Acyclic data (Records) Acyclic data are available in read-only or read/write access. They are accessed by using a slot, a sub slot and an index. eNod4 acyclic data are accessible with any slot and sub slot. Indexes for the eNod4 specific application data are presented in appendix. 7.9. PROFINET IO exchange of cyclic data Acyclic data modules are described in GSDML file. This file can be imported into the engineering tool used for application design. Data modules can be freely plugged into any slot from 1 to 8. This will define the organization of cyclic data in the AR (Application Relation). Unnecessary modules for the application may not be plugged. Inserting data provided by eNod4 automatically implies the insertion of data consumed by eNod4 if the concerned module contains consumed data. Presentation of provided data in modules: 34/75 eNod4-T Software user manual NU-soft-eNod4T-ETH-E-1014_216704-D