Appendix C Auxiliary Area Address Words Name A281 A28100 Pulse Output 1 Accel/Decel (CJ1M Flag CPU Units with built-in I/ O only.) 458 Function Settings Bits Status after mode change Status at startup Write timing Related flags, settings This flag will be ON when pulses are being output from pulse output 1 according to an ACC(888) or PLS2(887) instruction and the output frequency is being changed in steps (accelerating or decelerating). Cleared when operation starts or stops. 0: Constant speed 1: Accelerating or decelerating --- --- Cleared Refreshed each cycle during oversee process. A28101 Pulse Output 1 Overflow/ Underflow Flag This flag indicates when an overflow or underflow has occurred in the pulse output 1 PV. Cleared when operation starts. 0: Normal 1: Overflow or underflow --- --- Cleared Refreshed --when the PV is changed by the INI(880) instruction. Refreshed when an overflow or underflow occurs. A28102 Pulse Output 1 Output Amount Set Flag ON when the number of output pulses for pulse output 1 has been set with the PULS(886) instruction. Cleared when operation starts or stops. 0: No setting 1: Setting made --- --- Cleared Refreshed --when the PULS(886) instruction is executed. A28103 Pulse Output 1 Output Completed Flag ON when the number of output pulses set with the PULS(886) instruction has been output through pulse output 1. Cleared when operation starts or stops. 0: Output not completed. 1: Output completed. --- --- Cleared Refreshed --when PULS(886) (886) instruction is executed. Refreshed at the start or completion of pulse output. A28104 Pulse Output 1 Output Inprogress Flag ON when pulses are being output from pulse output 1. Cleared when operation starts or stops. 0: Stopped 1: Outputting pulses. --- --- Cleared Refreshed --when pulse output starts or stops. A28105 Pulse Output 1 No-origin Flag ON when the origin has not been determined for pulse output 1 and goes OFF when the origin has been determined. Turned ON when power is turned ON. Turned ON when operation starts. 0: Origin established. 1: Origin not established. --- --- Cleared Refreshed each cycle during overseeing processes. --- A28106 Pulse Output 1 At-origin Flag ON when the pulse output PV matches the origin (0). 0: Not stopped at origin. 1: Stopped at origin. --- --- Cleared Refreshed each cycle during overseeing processes. --- ---
Related documents
Version 1.9
SYSMAC CJ Series CJ1G CPU## Programmable Controllers
CS1PC-PCI01-DRM CS1PC-PCI01H-DRM CS1PC
OPERATION MANUAL
PROGRAMMING MANUAL Programmable Controllers
CS/CJ Series Programmable Controllers
CX-Programmer Operation Manual
Série CJ E/S intégrées UCs CJ1M-CPU21/22/23 Manuel d`utilisation
User Manual - FTP Directory Listing
Omron CS1D PCS User Manual
User Manual D637-R/D639-R Series Servo Valves
Automates programmables MANUEL D`UTILISATION