Download User-Manual
Transcript
Table 6. IMM2 error messages (continued) v Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved. v If an action step is preceded by “(Trained technician only),” that step must be performed only by a trained technician. 806f011b-0701xxxx The connector Info PwrPaddle Cable has encountered a configuration error. The connector PwrPaddle Cable has encountered a configuration error. 1. Reseat the power paddle cable on the system board. 2. Replace the power paddle cable. 3. (Trained technician only) Replace the system board. 806f0308-0a01xxxx 806f0308-0a02xxxx The Power Supply n has lost input. (n = power supply number) Info Power supply n AC 1. Reconnect the power cords. has lost. 2. Check power supply n LED. (n = power supply 3. See “Power-supply LEDs” on page number) 135 for more information. (n = power supply number) Error 80070208-0a01xxxx Sensor PS n Therm 80070208-0a02xxxx Fault has transitioned to critical from a less severe state. (n = power supply number) A sensor has changed to Critical state from a less severe state. 1. Make sure that there are no obstructions, such as bundled cables, to the airflow from the power-supply fan. 2. Use the IBM Power Configurator utility to determine current system power consumption. For more information and to download the utility, go to http://www-03.ibm.com/ systems/bladecenter/resources/ powerconfig.html. 3. Replace power supply n. (n = power supply number) Error 80070608-0a01xxxx Sensor PS n 12V 80070608-0a02xxxx AUX Fault has transitioned to non-recoverable from a less severe state. (n = power supply number) A sensor has changed to non-recoverable state from a less severe state. 80070608-0a01xxxx Sensor PS n 12V OC Error 80070608-0a02xxxx Fault has transitioned to non-recoverable from a less severe state. (n = power supply number) A sensor has changed to non-recoverable state from a less severe state. 1. Check power supply n LED. 2. Replace power supply n. (n = power supply number) 1. Use the IBM Power Configurator utility to determine current system power consumption. For more information and to download the utility, go to http://www-03.ibm.com/ systems/bladecenter/resources/ powerconfig.html. 2. Check the OVER SPEC LED in “Light path diagnostics LEDs” on page 129 and Pwr Rail (A, B, C, D, E, F, G, and H) error has been recorded in the IMM2 event log (see “Power problems” on page 115 for more information). Chapter 3. Diagnostics 55