Table 6. IMM2 error messages (continued)
v Follow the suggested actions in the order in which they are listed in the Action column until the problem
is solved.
v If an action step is preceded by “(Trained technician only),” that step must be performed only by a trained
technician.
806f011b-0701xxxx
The connector
Info
PwrPaddle Cable has
encountered a
configuration error.
The connector
PwrPaddle Cable
has encountered a
configuration error.
1. Reseat the power paddle cable on
the system board.
2. Replace the power paddle cable.
3. (Trained technician only) Replace
the system board.
806f0308-0a01xxxx
806f0308-0a02xxxx
The Power Supply n
has lost input.
(n = power supply
number)
Info
Power supply n AC 1. Reconnect the power cords.
has lost.
2. Check power supply n LED.
(n = power supply
3. See “Power-supply LEDs” on page
number)
135 for more information.
(n = power supply number)
Error
80070208-0a01xxxx Sensor PS n Therm
80070208-0a02xxxx Fault has transitioned
to critical from a less
severe state.
(n = power supply
number)
A sensor has
changed to Critical
state from a less
severe state.
1. Make sure that there are no
obstructions, such as bundled
cables, to the airflow from the
power-supply fan.
2. Use the IBM Power Configurator
utility to determine current system
power consumption. For more
information and to download the
utility, go to http://www-03.ibm.com/
systems/bladecenter/resources/
powerconfig.html.
3. Replace power supply n.
(n = power supply number)
Error
80070608-0a01xxxx Sensor PS n 12V
80070608-0a02xxxx AUX Fault has
transitioned to
non-recoverable from
a less severe state.
(n = power supply
number)
A sensor has
changed to
non-recoverable
state from a less
severe state.
80070608-0a01xxxx Sensor PS n 12V OC Error
80070608-0a02xxxx Fault has transitioned
to non-recoverable
from a less severe
state.
(n = power supply
number)
A sensor has
changed to
non-recoverable
state from a less
severe state.
1. Check power supply n LED.
2. Replace power supply n.
(n = power supply number)
1. Use the IBM Power Configurator
utility to determine current system
power consumption. For more
information and to download the
utility, go to http://www-03.ibm.com/
systems/bladecenter/resources/
powerconfig.html.
2. Check the OVER SPEC LED in
“Light path diagnostics LEDs” on
page 129 and Pwr Rail (A, B, C, D,
E, F, G, and H) error has been
recorded in the IMM2 event log
(see “Power problems” on page 115
for more information).
Chapter 3. Diagnostics