Download Catalog - HoHo Technology Co., Ltd.
Transcript
Variable Speed Rotating Mixer and HPLC Column Chiller / Heater Model RT10 - Variable Speed Rotating Mixer The Model RT10 variable speed rotating mixer is designed to mix 0.5 and 1.5ml centrifuge tubes in an end over end motion and 15ml and 50ml tubes in a horizontal rolling motion at speeds varying from 4 to 40 rpm using a simple knob control. The unit is provided with a mounting rack that holds 50-0.5 ml centrifuge tubes and 48-1.5ml centrifuge tubes. Accessory racks can be ordered that hold 16-15ml tubes or 6-50ml tubes. Changing from the provided rack to accessory racks can be done in just minutes. The rod holding the racks is easily removed for changing from one rack to another. The unit is compact measuring only 4.5” (11.43 cm) wide by 13.7” (34 cm) long by 6.75” (17.15 cm) high. It weighs only 5 pounds (2.25 kg). It is powered by a 12VDC power supply that operates from 100 to 260VAC, 50/60Hz inputs. It draws less than 1 amp. The unit comes complete with rotator, racks for 0.5ml and 1.5ml centrifuge tubes, 12 VDC bench top power supply that takes AC inputs from 100 to 260VAC, 50/60Hz, 3wire AC line cord for the country of use, and user’s manual. It has a full 12 month warranty. It is UL, CSA and CE compliant. See Price list for Accessories holding 15 ml and 50 ml centrifuge tubes. Model C030 - HPLC Column Chiller / Heater The Model CO30 is an HPLC column chiller/heater with a temperature range from 4.0ºC, or 12 to 16ºC below ambient maximum, to 70.0º. It is accurate to ± 0.2C, readable and settable to 0.1C, and can control temperature to 0.1ºC with its PID control loop software. It is Peltierdriven for both heating and cooling making it CFC free. It has only 2 moving parts, the fans, making it 22 very reliable. It has a very large chamber measuring 15.5” (39.37 cm) high x 6.385” (16.28 cm) wide x 5.125” (13.02 cm) deep. The chamber will easily hold 4-30 cm x 1” columns and a Rheodyne valve. Chamber temperature uniformity is ± 0.5ºC. alarm and user settable Auto-Off that will shut off the chiller/heater after the count down period. It has an RS232 I/O port for data logging or for controlling the unit from a computer or chromatograph. The CO30 also has a power failure reset system that will reset the unit to the temperature it was running when power returns. It has electronic calibration that is easily reset to local standards if necessary. The door design is unique in that it opens out and down from the top. All columns, valves and fittings are mounted on the door exposing everything to simple and easy unobstructed access. It has drains in the door for the valve and in the chamber floor for spills. The unit has a liquid crystal display used for showing the chamber temperature and the count down timer. The unit has a 99hour count down timer with audible The CO30 can be ordered in models for 100 or 115VAC, 50/60 Hz, 2 amp, or 230VAC, 50/60 Hz, 1 amp. It comes complete with user’s manual, two sizes of “O” rings for mounting columns, fused and switched AC input module, 3-wire line cord for the country of use, and 12 month warranty. The unit measures 25.5” (64.77 cm) tall x 8.75” (22.23 cm) wide x 13.5” (33.66 cm) deep and weighs 25 pounds (11.26 kg). All are UL, CSA, and CE compliant.