Controller Menu
Notes about Sample Periods
1.
A new record will be automatically created within a sampling period if the
C/S/O/SYS/MAX should change within the sampling period.
2.
Each record is always a whole number of cycles; thus, the actual period ends
on the termination of the last cycle after the sampling period ends.
3.
Cycles are based on the ring 1 coordinated phase end of green.
4.
If MOE's are to be collected during free operation, be sure to still program
Cycle 1/Split 1 coordinated phases (main street). The LMD uses the end of the
ring 1 coordinated phase to determine the end of a cycle.