Controller Menu Notes about Sample Periods 1. A new record will be automatically created within a sampling period if the C/S/O/SYS/MAX should change within the sampling period. 2. Each record is always a whole number of cycles; thus, the actual period ends on the termination of the last cycle after the sampling period ends. 3. Cycles are based on the ring 1 coordinated phase end of green. 4. If MOE's are to be collected during free operation, be sure to still program Cycle 1/Split 1 coordinated phases (main street). The LMD uses the end of the ring 1 coordinated phase to determine the end of a cycle. CLMATS Operating Manual 249