Parameter
Station ID
Ref. Health
Max Age
Quality
Auto-differential Mode
Reset RTCM Processing
Use Sequence Numbers
Description
When in the Base Station mode, the receiver will use this
information as its reference station ID (STID). When in
Remote Station mode, the field identifies the RTCM Base
station source for RTCM messages. This field will be disabled
when not in Base or Remote RTCM mode.
The health of the reference station (or STHE). This field is
not editable when in the RTCM Remote mode or the Disabled
mode. When set in Base mode, the receiver does not permit
lower values of the reference station health unless the RTCM
processing is reset. Thus, you will not be permitted to enter
values lower than are currently entered in the field unless you
check the “Reset RTCM Processing” checkbox in this
window.
The primary use of this field is to specify the maximum age
(MAXAGE), in seconds, of RTCM Base station messages to
be applied in a Remote station processing.
In Remote Mode, this field (QAFREQ) allows for the
evaluation of the communication quality between the base
station and the user equipment. The field is not applicable
when in RTCM Base mode. To get a full meaning of this
parameter, please consult your receiver operations manual.
When checked, permits the automatic differential mode of the
receiver (Remote mode only). Allows the receiver to compute
autonomous positions when no RTCM differential corrections
are available or have exceeded the MAX Age parameter.
Checking this checkbox and then pressing the “Send” button
will reset the RTCM processing within the receiver. Consult
your Receiver Operations Manual for more details.
This checkbox instructs the RTCM Remote receiver to utilize
the sequence numbers in the RTCM messages to enhance the
communication synchronization checks. Consult your
Receiver Operations Manual for more details.