Download Neutron Engineering Inc.
Transcript
Neutron Engineering Inc. 2.1 TEST FACILITY The test facilities used to collect the test data in this report is C01/OS01 at the location of No.132-1, Lane 329, Sec. 2, Palain Road, Shijr City, Taipei, Taiwan. 2.2 MEASUREMENT UNCERTAINTY The reported uncertainty of measurement y ± U,where expended uncertainty U is based on a standard uncertainty multiplied by a coverage factor of k=2,providing a level of confidence of approximately 95%。 A. Conducted Measurement : Test Site C01 Method ANSI Measurement Frequency Range 150 KHz ~ 30MHz U,(dB) 1.94 NOTE U,(dB) NOTE B. Radiated Measurement : Test Site Method OS-01 ANSI OS-02 ANSI Measurement Frequency Range 30MHz ~ 200MHz 30MHz ~ 200MHz 200MHz ~ 1,000MHz 200MHz ~ 1,000MHz 30MHz ~ 200MHz 30MHz ~ 200MHz 200MHz ~ 1,000MHz 200MHz ~ 1,000MHz Report No.: NEI-FCCE-1-E0712010 Ant. H/V V H V H V H V H 3.82 3.60 3.86 3.94 2.48 2.16 2.50 2.66 Page 6 of 32