2.6.1
Section 2. Quick Start
Power Supply
There are two LEDs on the power supply module. They are labeled "ANLG" and "DGTL" (See
2.7.1 Power Supply Module for location). These LEDs show the two power supply voltages:
analog and digital. They should be illuminated when power is supplied to the unit.
2.6.2
NMS/CPU
The LED on the NMS/CPU board indicates that the CPU board is functioning. It should be
illuminated at all times. See 2.7.2 NMS Module for LED location.
2.6.3
I-Mux (6-Port Mux)
Sync 1 and Sync 2 LEDs indicate the Multiplexer and Demultiplexer status on the I-Mux (6Port Mux).
LED Color
Indication
Dark
Problem with module
Yellow
Module is working, not locked
Green
Module is working and clock and frame are locked
See 2.7.3 I-Mux (6-Port Mux) Module for LED locations.
2.6.4
Fractional/Full T1
The D5 Led on a T1 card indicates the status of the T1 link. On some systems, this LED is
replicated on the rear panel of the I-Mux (6-Port Mux). The following table describes the D5
T1 LED for v1.1 and later.
D5 LED Color
Full T1 Meaning
Fractional T1 Meaning
Notes
GREEN
T1 signal present, T1 clock
present, data normal
T1 signal present, T1 clock
present, data normal
Normal Operation
ORANGE
Incoming frequency out of
tolerance (FIFO over/under
run)
Incoming frequency out of
tolerance (FIFO over/under
run)
Check signal source
RED/OFF
1 pulse/sec
N/A
T1 Fractional Error
Check signal source or
external link
RED/OFF
2 pulses/sec
N/A
FT1 Fractional Error
Check signal source or
external link
RED/GREEN
alternating
Bipolar Violation
Bipolar Violation
Check signal source
RED
Loss of Signal
Loss of Signal
Check cabling,
this end
OFF
No power or no firmware
No power or no firmware
Check board seating
The following table describes the D5 T1 LED for v1.0.
D5 LED Color
Meaning
Notes
RED
T1 signal present, no T1 clock or data (all 0s)
Check T1 circuit
GREEN
T1 signal present, T1 clock present,
no data (all 1s)
Check cabling on far end
or A1S error from far end
ORANGE (normal)
T1 signal present, T1 clock present,
data present
Normal operation
OFF
No T1 signal or no power
Check cabling on this end