6 COMMUNICATION SETTING EXAMPLES OF THE UTILITY SETTING TYPE
MELSOFT
(6) Setting the logical station number (Setting on communication
setting wizard)
Logical station number setting will be described using the system example for Q
series-compatible E71.
1) Start the communication setup utility and select the
communication setting wizard.
2) Type "2" in Logical station number and click Next> .
3) Make settings as indicated below and click Next> .
PC side I/F
Connect module
Protocol
Network No
Station No
Time out
: Ethernet board
: QJ71E71
: TCP
:1
:2
: 60000
4) Make settings as indicated below and click Next> .
PLC side I/F
Module type
Host (IP Address)
Station No
: Ethernet module
: QJ71E71
: 192.168.0.1
:1
(To the next page)