Download Capstone Microturbines

Transcript
CHAPTER 7
PERFORMANCE
Capstone
Table 7-1. Capstone Model C200 Microturbine Performance Summary
Parameter
C200 Low Pressure NG
All Other C200
Net Power Output
190 (+0/-4) kW net
200 (+0/-4) kW net
Net Efficiency (LHV)
31 (r 2)%
11,600 kJ/kWh
(11,000 Btu/kWh)
10,700 kJ/kWh
(10,200 Btu/kWh)
2,400,000 kJ/hr
(2,280,000 Btu/hr)
33 (r 2)%
10,900 kJ/kWh
(10,300 Btu/kWh)
10,200 kJ/kWh
(9,700 Btu/kWh)
2,400,000 kJ/hr
(2,280,000 Btu/hr)
Nominal Net Heat Rate (LHV)
Nominal Generator Heat Rate
(LHV)
Nominal Steady State Fuel Flow
(HHV) (1) (2)
Notes:
(1) The ratio of Higher Heating Value (HHV) to Lower Heating Value (LHV) is assumed to be 1.1.
(2) Onload fuel flows can be up to two times higher than the steady state values.
How to Use This Section
The following pages present several tables and graphs for determining the nominal net power output,
efficiency, and exhaust characteristics for various operating conditions.
Table 7-5 at the end of this section provides an example calculation. The basic method is
summarized below:
x
Look up the efficiency, exhaust temperature, and exhaust mass flow for a given
temperature using Table 7-2.
x
Estimate the power output using Figure 7-2 for a given temperature and elevation.
x
Apply inlet pressure loss power and efficiency correction factors (if any) using Table
7-3.
x
Apply back pressure power and efficiency correction factors (if any) using Table 7-4.
x
Calculate nominal net power output and fuel input for the given operating conditions.
x
Define parasitic loads (Fuel Gas Booster, water pump, etc.).
x
Estimate exhaust temperature and flow for the given operating conditions.
In addition to the steps above, tolerances for a given application must be considered. Refer to the
Consider Tolerances section of this document for more information.
Ambient Temperature Table
Nominal net power output, efficiency, and exhaust characteristics versus ambient temperature at sea
level for the Capstone C200 high pressure natural gas model microturbine are presented in
Table 7-2. These values are estimated from nominal performance curves.
410066 Rev C (June 2009)
Capstone reserves the right to change or modify, without notice, the design, specifications, and/or contents of this document
without incurring any obligation either with respect to equipment previously sold or in the process of construction.
7-4