Transcript
| Status Registers | Bit 2 is the Value Adapted Bit, indicating that a parameter value was adapted during a previous commandinterpretation. Bit 4 is the Message Available (MAV)bit, indicating that the interface output queue is not empty. Bit 5 of STBis the summarybit ESBof the Standard Event Status Register. It is set if any of the bits of the ESRare set, provided that they are enabled by the corresponding bit of the ESEregister. Bit 6 of the Status Byte Register (STB) is alternatively called the Master SummaryStatus bit (MSS) or the Request for Service bit (RQS) because the STB can be read in two different ways. The command"*STB?" reads and clears the STB in the query mode, in which case bit 6 of the STBis the MSSbit, indicating if the instrument has any reason for requesting service. The other way of reading the STBis the serial poll (see Section 3, page 22, for the GPIBserial poll procedure). In this case, bit 6 of the STBis the RQSbit, indicating that the instrument has actually activated the SRQline on the GPIB. The serial poll only clears the RQSbit. Therefore, the MSSbit of the STB (and any other bits which caused MSSto be set) will stay set after a serial poll. The controller must reset these bits. The Status Byte Register may be read via the query "* STB?". The response represents the binary weighted sum of the register bits. The register is cleared by "*STB?", "ALST?", "*CLS" or after the instrument has been powered up. STANDARD EVENT STATUS REGISTER (ESR) Example 194 The ESRis a 16-bit register reflecting the occurrence of events. The register bit assignments have been standardized by IEEE 488.2. Only the lower 8 bits are currently in use. The Standard Event Status Register may be read via the query "*ESR?". The response is the binary weighted sum of the register bits. The register is cleared with an "*ESR?"or "ALST?"query, a "*CLS" command or after power-on. The response message "*ESR 160" indicates that a commanderror occurred and that the ESRis being read the first time after power-on. The value 160 can be broken down into 128 (bit 7) plus 32 (bit 5). See Table 5, page 82, for a description of the conditions corresponding to the bits set. The "Power ON"bit appears only on the first "*ESR?"query after power-on because the query clears the register. The type of command error can be determined by reading the CommandError Status Register with the query "CMR?".Note that it is not necessary to read (and simultaneously clear) this register in order to able to set the CMRbit in the ESRon the next commanderror.