Download Instruction Manual
Transcript
8.1.2 Three-phase 400 V series *1 Fuji 4-pole standard motors *2 The rated capacity is for 440 V output voltage. *3 Output voltages cannot exceed the power supply voltage. *4 Interphase voltage unbalance (%) = Max.voltag e (V) - Min.voltag e (V) × 67 (Refer to IEC 61800 - 3 (5.2.3)) 3 - phase average voltage (V) If this value is 2 to 3 %, use an AC reactor (ACR). *5 Tested under the standard load condition (85% load for applicable motor rating). *6 Calculated under Fuji-specified conditions. *7 Indicates the value when using a DC reactor (option). *8 Average braking torque obtained with the AVR control off (F 05 =0). (Varies according to the efficiency of the motor.) *9 Average braking torque obtained by use of an external braking resistor (standard type available as option). *10 To make FRENIC-Mini compliant with category TYPE1 of the UL Standard (or NEMA1), an optional NEMA1 kit is required. Note that the TYPE1-compliant FRENIC-Mini should be used in the ambient temperature range from -10 to +40°C. Note: A box () in the above table replaces A, C, E, or J depending on the shipping destination. Note that the FRN4.0C1S-4 can be followed by E only. 8-2