SPECIFICATIONS
POWER
115 vac minimum / 60 hz / 3 prong grounded outlet. The unit should be installed on a
dedicated 15 amperes branch circuit (20 amperes if shared with other devices).
Electric consumption during wash operations: <1 amp.
Electric consumption during recycle operations: No greater than 12 amps.
NOTE: If multiple units are placed in older facilities, it is recommended to operate the
recycle process at staggered intervals or a low electrical usage periods to avoid
excessive electrical demand on the main service panel.
SOLVENT
Standard models use only 140°F flash mineral spirits (Aliphatic Hydrocarbon) with an
upper limit boiling point no higher than 425°F. VOC exempt models use only solvent
provided by or approved for use by SYSTEMOne®.
NOTE: Solvent replenishment requirements range from 15 to 30 gallons per year per
unit, depending on the application and useage. Solvent requirements over 30 gallons
per year represents unusual usage. In cases where solvent usage exceeds 30 gallons
per year, the customer should take action to determine the cause for loss. Typically, the
solvent is being removed for remote cleaning operations and not replaced in a timely
fashion. Management should take action to deter improper removal of solvent form the
SYSTEMOne® parts washer.
DIMENSIONS
MODEL 300
FLOOR SPACE
27” x 32”
WORKING HEIGHT
33”
WEIGHT
480 lbs. full
SINK CAPACITY
3 gallons
RESERVOIR CAPACITY 19 gallons
MODEL 500
30” x 39”
32”
552 lbs. full
5 gallons
29 gallons
-6-
MODEL 550
36” x 48”
32”
585 lbs. full
5 gallons
29 gallons
MODEL 570
33” x 45”
32”
572 lbs. full
5 gallons
29 gallons