Download LinMot - Profilex Systems

Transcript
LinMot 
CANopen Interface
13 Reset Parameters to default values on E1100
There are three options to reset the parameters of a LinMot E1100 controller to default values:
1)
2)
3)
By manipulating the two rotary hex switches:
- Power Off the controller
- Set the switches to FF
- Power On the controller
- Set the switches to 00
- Wait for 10 s
- Power Off the controller
By writing Index 2000h sub-index 7h, 8h, 9h, Ah of the Object dictionary.
After changing the ROM values, a Reset should be performed either by a NMT Reset
command or by Power OFF and ON the controller.
Reinstall the firmware will always reset the parameters to default values
Page 34/38
User Manual CANopen Interface / 23/05/11
NTI AG / LinMot