Download Excellence 50XT
Transcript
INSTAL L ATIO N MA N U A L Error messages English Error code Problem F08 (follow-up) Possible cause Remedy Ionization pin defective (measure ionization current when 0) Replace the ionization pin F12 ESYS is not released ESYS is in hard-lock Wait half hour until ESYS resets itself. F13 Flame loss when only the main burner is on Gas has fallen away Check gas supply Gas control defective (see "A" in app. 3, fig. 38) Replace the gas control Suffocation due to poor flue gas channel Check the concentric system Check the setting of the appliance F14 Flame loss if both burners are on. Suffocation when using PowerVent Check the pressure setting of the PowerVent system 24 hour check control Reset with remote control (consult Powervent manual) Gas has fallen away Check gas supply Gas control defective (see "A" in appendix 3, fig. 38) Replace the gas control Suffocation due to poor flue gas channel Check the concentric system Check the setting of the appliance Suffocation when using PowerVent Check the pressure setting of the PowerVent system Burner device came loose from burner device Attach the burner device Burner device incorrectly mounted Mount the burner device correctly Pins on the connector on the gas control are bent Bend them straight High limit error High limit bridge defective Check High limit bridge ESYS F16 Hardware Error ESYS ESYS defective (burner device) Replace ESYS (burner device) F17 Disable contact is closed Window is open. (if this contact is present) Close window A bridge has been made across the Disable contact. Remove bridge on ESYS (burner device) F15 UK No burner device (see "C" in appendix 3, fig. 38)